E-resources
Peer reviewed
-
Pauli, Thomas W; Gangaputra, Sapna; Hubbard, Larry D; Thayer, Dennis W; Chandler, Charles S; Peng, Qian; Narkar, Ashwini; Ferrier, Nicola J; Danis, Ronald P
Investigative ophthalmology & visual science, 2012-Aug-01, 2012-08-01, 20120801, Volume: 53, Issue: 9Journal Article
Changes in retinal vascular caliber measured from digital color fundus photographs have been independently associated with systemic outcomes in epidemiologic studies, but the effect of image resolution and compression on vascular measurements has not been previously evaluated. To explore image compression, 40 natively digital fundus images were selected with good photo quality, high spatial resolution, and no previous image compression. Using Adobe Photoshop, these images were compressed at progressively higher levels up to 147:1, and then retinal vascular caliber was measured at each level using semiautomated software. To examine resolution, 40 fundus photographs acquired on high-resolution film were scanned with settings corresponding to 10, 7, 5, 3, and 1 megapixel fundus cameras. After adjusting for scale factor, vascular caliber was measured at each level of resolution. Data were analyzed by comparing the calculated central retinal arteriole equivalent (CRAE) and the central retinal venular equivalent (CRVE) of the original and altered images, using repeated measures ANOVA. CRAE became significantly wider with increasing levels of compression at the 25:1 threshold (~1 μm wider, P < 0.001) and was ~5 μm wider with 147:1 compression. CRVE also increased, but less than CRAE. Using 7 (megapixel)-MP resolution as the standard, CRVE was significantly narrower at the 5-MP simulation (~2 μm, P < 0.001) and was ~12 μm narrower at the 1-MP simulation. CRAE also decreased, but less than CRVE. Increasing digital image file compression and decreasing fundus image spatial resolution led to skewed measurements of the retinal vascular caliber.
Shelf entry
Permalink
- URL:
Impact factor
Access to the JCR database is permitted only to users from Slovenia. Your current IP address is not on the list of IP addresses with access permission, and authentication with the relevant AAI accout is required.
Year | Impact factor | Edition | Category | Classification | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Select the library membership card:
If the library membership card is not in the list,
add a new one.
DRS, in which the journal is indexed
Database name | Field | Year |
---|
Links to authors' personal bibliographies | Links to information on researchers in the SICRIS system |
---|
Source: Personal bibliographies
and: SICRIS
The material is available in full text. If you wish to order the material anyway, click the Continue button.