    Lindholm, C; Pekkarinen, A; Sipilä, O; Manninen, A-L; Lehtinen, M; Siiskonen, T

    Radiation protection dosimetry, 08/2020, Volume: 190, Issue: 2
    Journal Article

    Abstract The eye lens exposure among 16 technicians in two nuclear medicine departments at university hospitals in Finland was investigated by measuring the operational quantity Hp(3) using EYE-D dosemeters. For all workers, the annual mean Hp(3) was estimated to be 1.1 mSv (max. 3.9 mSv). The relation between Hp(3) to routinely monitored personal dose equivalent Hp(10) was clearly correlated. Considering individual dose measurement periods (2–4 weeks), the Hp(3)/Hp(10) ratio was 0.7 (Pearson’s coefficient r = 0.90, p < 0.001, variation of ratio 0.1–2.3). The variation decreased considerably with increasing Hp(10) (σ2 = 0.04 vs. 0.43 for Hp(10) > 0.1 mSv vs. < 0.1 mSv, respectively), i.e. higher Hp(10) predicts Hp(3) more reliably. Moreover, annual Hp(10) data from national dose register during 2009–2018 were used to derive the annual Hp(3) applying the Hp(3)/Hp(10) ratio. The data from Finnish nuclear medicine departments imply that routine measurements of Hp(3) among nuclear medicine technicians are not justified.