-
Zdravljenje primarnega glavkoma zaprtega zakotja z odstranitvijo sive mrene = Management of primary angle closure glaucoma with cataract extractionSchwarzbartl Pfeifer, Marija Ana ; Zupan, Marija, okulistika, 1941- ; Pfeifer, Vladimir, 1955-Background. We investigate the clinical result of phacoemulsification with foldable posterior chamber intraocular lens (PC-IOL) implantation in the management of primary angle closure glaucoma with ... cataract. Methods. We performed phacoemulsification with foldable PC-IOL implantation in the eyes with primary angle closure glaucoma and cataract. Methods. We performed phacoemulsification with foldable PC-IOL implantation in the eyes with primaryangle closure glaucoma and cataract. Eyes were divided in three groups.In the first group were eyes with primary acute-closed angle glaucoma with no PAS (peripheral anterior synechiae). In the second group were eyes with primary chronic angle-closure glaucoma with less than 180 degrees of PAS.In the third group were eyes with primary chronic angle-closure glaucoma with more than 180 degrees of PAS seen on gonioscopic examination. Results. Inthe first group of 15 patient mean follow up time was 10.7 month. IOP changefrom mean 58 mmHg to mean 13.5 mmHg postoperative. ACD change from 2.31 mm to 3.67 mm postoperative. Best corrected visual acuity change from 0.25 to 0.7 postoperative. In the second group of 30 patient mean follow up time was 15.9 months. IOP fall from mean 19.9 mmHg to mean 12.1 mmHg postoperative. ACDchange from 2.45 mm to 3.93 mm postoperative. Best corrected visual acuity change from 0.4 to 0.83 postoperative. In the third group of 15 patient mean follow up time was 9.6 month. IOP fall from mean 16.4 mmHg to mean 14.5 mmHg postoperative. ACD change from 2.51 mm to 4.20 mm postoperative. Best corrected visual acuity change from 0.25 to 0.54 postoperative. Conclusions. Phacoemulsification with PC-IOL implantation can be a good alternative in treating eyes with cataract and primary acute and chronic angle closure glaucoma with less than 180 degrees of PAS seen on gonioscopic examination. (Abstract truncated at 2000 characters)Vir: Zdravniški vestnik : glasilo Slovenskega zdravniškega društva = Slovenian medical journal = journal of Slovenian Medical Association. - ISSN 1318-0347 (Letn. 74, št. 10, okt. 2005, str. 657-662)Vrsta gradiva - članek, sestavni delLeto - 2005Jezik - slovenskiCOBISS.SI-ID - 20412121
Avtor
Schwarzbartl Pfeifer, Marija Ana |
Zupan, Marija, okulistika, 1941- |
Pfeifer, Vladimir, 1955-
Teme
Glaucoma, Angle-Closure |
Cataract Extraction |
Gonioscopy |
Phacoemulsification |
Fakoemulzifikacija |
Glavkom zaprtega zakotja |
Gonioskopija |
Katarakta, ekstrakcija |
očesne bolezni |
glavkom |
siva mrena |
zdravljenje
![loading ... loading ...](themes/default/img/ajax-loading.gif)
vir: Zdravniški vestnik : glasilo Slovenskega zdravniškega društva = Slovenian medical journal = journal of Slovenian Medical Association. - ISSN 1318-0347 (Letn. 74, št. 10, okt. 2005, str. 657-662)
![loading ... loading ...](themes/default/img/ajax-loading.gif)
![loading ... loading ...](themes/default/img/ajax-loading.gif)
![loading ... loading ...](themes/default/img/ajax-loading.gif)
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|---|
Schwarzbartl Pfeifer, Marija Ana | 23762 |
Zupan, Marija, okulistika, 1941- | ![]() |
Pfeifer, Vladimir, 1955- | 18629 |
Izberite prevzemno mesto:
Prevzem gradiva po pošti
Obvestilo
Gesla v Splošnem geslovniku COBISS
Izbira mesta prevzema
Mesto prevzema | Status gradiva | Rezervacija |
---|
Prosimo, počakajte trenutek.
Naročanje gradiva za izposojo v čitalnice
Naročanje kopij člankov
Urnik dostave gradiva z oznako DS v signaturi