Extraoral vertical ramus osteotomy (EVRO) is used in orthognathic surgery for the treatment of mandibular deformities. Originally, EVRO required postoperative intermaxillary fixation (IMF). EVRO has ...been developed using rigid fixation, omitting postoperative IMF. We examined retrospectively the long-term stability and postoperative complications for patients with mandibular deformities who underwent EVRO with internal rigid fixation. Patients who were treated with EVRO for a mandibular deformity in the period 2008–2017 at the Clinic of Oral and Maxillofacial Surgery, Mölndal, Sweden were included (N = 26). Overjet and overbite were calculated digitally and cephalometric analyses were performed preoperatively, and at three days, six months, and 18 months postoperatively. There was a general setback of the mandible, decreased gonial angle and reduced degree of skeletal opening. Excellent dental and vertical skeletal stabilities were seen up to 18 months postoperatively, although relapse was seen sagitally up to six months postoperatively. Since the overjet did not show any significant change over time, the sagittal skeletal changes have been attributed to dental compensation. There was no permanent damage to the facial nerve and 5.8% neurosensory damage to the inferior alveolar nerve was observed.
This study reports torsion tests and pull-out tests on osseointegrated commercially pure titanium fixtures. The tests were performed
in vivo on a total of 26 rats. Three fixtures with a diameter of ...2.0 mm were installed bilaterally in the proximal tibia in each animal. The mechanical testing was performed immediately after installation, after 2, 4, 8 and 16 weeks of unloaded healing. The torsional strength started to increase after 4 weeks of unloaded healing and there was a significant increase with time during the initial 16 weeks. The pull-out load increased rapidly during the first 4 weeks; thereafter, a moderate increase occurred during the following 12 weeks. A histological evaluation was performed after 0, 4, 8 and 16 weeks. There were significant (
P < 0.01) correlations between torque and percentage of bone in contact with the fixture, and between pull-out load and the bone thickness around the fixture (
P < 0.001). Estimations of shear stresses and shear moduli in the bone tissue (pull-out test) and at the interface (torque test) indicated that the increase in bone volume around the implant substantially improved the mechanical capacity.
ABSTRACT
Background: Brånemark fixtures were originally prescribed to be placed in two surgical stages. During the past years, reports on the placement of machined titanium implants in a one‐stage ...procedure have been published, and the results have been encouraging. Recendy there has been considerable interest in early or immediate loading.
Purpose: The purpose of this article is to report the preliminary clinical results of a new method for implant treatment of the edentulous mandible. The new protocol involves prefabricated components and surgical guides, elimination of the prosthetic impression procedure and attachment of the permanent fixed bridge on the day of implant placement.
Methods: Fifty patients (26 males, 24 females) received 150 Brånemark Novum implants and were followed from 6 months to 3 years after implant placement. Bone width and height were determined preoperatively with the use of radiographs. The jaw was reduced in height to accommodate three special 5‐mm wide implants. Precise implant positioning was accomplished with special drilling templates. Drill guides were placed over the drilling templates during site preparation using a series of specially designed drills. After the mucosa had been sutured back into position, a prefabricated titanium lower bar was connected with titanium screws to the transmucosal fixture. Another titanium bar was then attached by the prosthodontist, and a bite registration was performed. The bridge was attached to the upper bar. The permanent reconstruction was provided to the patient later the same day.
Results: Three implants were lost to follow‐up and three failed, resulting in an overall survival rate of 98%. One prosthesis failed, leaving a prosthetic survival rate of 98%. The average treatment time was approximately 7 hours. At the baseline examination, the marginal bone level was 0.72 mm below the reference point. The average marginal bone loss was 0.2 mm per year and 0.26 mm between the 3‐month and 1‐year control visits. The accumulated mean bone loss, including baseline, was‐1.25 mm. A patient questionnaire demonstrated that 94% of the patients did not experience any discomfort during treatment and all patients would recommend the procedure to others.
Conclusion: The results of this study indicate that the precise surgical and prosthetic protocol allows successful prosthetic rehabilitation of mandibular edentulism and that the permanent reconstruction can be provided to the patient on the day of fixture surgery.
This study reports the results of torsion tests, pull-out tests, and lateral loading tests on osseointegrated commercially pure titanium fixtures. The tests were performed in vivo on six beagle dogs. ...Three fixtures, each with a diameter of 3.7 mm, were installed bilaterally in the tibia of each animal. The mean maximal pull-out load was 1.55 kN (n = 4), the mean maximal lateral transverse load was 0.21 kN (n = 2), the mean maximal lateral axial load was 0.18 kN (n = 2), the mean breakpoint torque was 0.31 Nm (n = 3), and the mean maximal torque was 0.43 Nm (n = 3). The torsion test revealed an almost immediate plastic deformation of the interface between the implant and bone; this indicates that although the contact between the bone and the implant is close, there is no strong bond, at least not in shear. The major transfer of load from the implant to the surrounding bone tissue must therefore depend on the design of the implant. A histological evaluation with measurements of the amount of bone in contact with the fixtures was performed. By the use of the histological and mechanical data, it is possible to estimate shear stresses in bone tissue (pull-out test) and in the interface (torque test). The mean maximal shear stress in bone tissue in the pull-out tests was 100 MPa (n = 4); the mean shear stress in the interface was 4.3 MPa (n = 3) in the torsion tests at the breakpoint torque and was 6.0 MPa (n = 3) at the maximal torque. It was also possible to estimate the shear modulus of elasticity in the pull-out and torque tests. The mean shear modulus in pull-out was 119 MPa (n = 4), and the mean apparent shear modulus in torsion was 9 kPa (n = 3) for an assumed interface thickness of 100 nm and was 86 kPa (n = 3) for an assumed interface thickness of 1,000 nm.
Purpose The purpose of this clinical investigation was to evaluate the treatment outcome with zygoma implants with regard to implant survival, patient satisfaction, and function of prosthesis ...replacement after 3 years. Patients and Methods The treatment outcome of 76 patients treated with 145 zygoma fixtures at 16 centers was evaluated with regard to implant survival. Status of peri-implant mucosa and amount of plaque were registered annually. Patients’ and dentists’ evaluations of the functional and esthetic outcome of the treatment were assessed at delivery of prosthesis and thereafter at each follow-up visit. Results Sixty of 76 patients were followed for 3 years after prosthetic delivery. Five of 145 placed zygoma implants failed during the course of the study resulting in an overall implant survival rate of 96.3%. At the 3-year follow-up, 75% of the implants sites were registered with normal peri-implant mucosa and 68% with no visible plaque. The patients were fully satisfied with the esthetic and functional outcome of the treatment in 86% and 71%, respectively, at the 3-year follow-up visit. All reported data from dentists scored from acceptable to excellent. Conclusion The multicenter study showed a high predictability of the zygoma implant-supported rehabilitation.
The rehabilitation of maxillary defects is a significant challenge in terms of creating retention and preserving existing dentition in an environment of expanded functional stress. The advent of ...osseointegration has enhanced the dental practitioner's capabilities in this regard with a remarkably improved potential for increasing prosthesis stability and preserving tissue. For patients with extensive prosthetic cantilevers, however, the opportunity for implant placement in defect areas is compromised unless remote bone sites are considered. Implants in the defect buttress zone through the maxillary sinus in non-defect sites (zygoma implants) can be valuable in providing a level of functional rehabilitation previously unattainable. (J Prosthet Dent 2001;86:377-81.)
To evaluate treatment outcome with Zygoma fixtures (Nobel Biocare, Göteborg, Sweden) with regard to fixture survival, patient satisfaction, and function of prosthesis replacement.
The treatment ...outcome of 76 patients treated with 145 Zygoma fixtures at 16 centers was evaluated. Patient’s and dentist’s evaluations of the functional and aesthetic outcome of the treatment were assessed at delivery of prosthesis and at the 1-year follow-up visit. At the 1-year follow-up visit, the status of the peri-implant mucosa around the abutments and the amount of plaque were registered.
Sixty-six of the 76 patients, with 124 Zygoma fixtures supporting the prosthetic restorations, were evaluated at the 1-year follow-up. The overall survival rate for the Zygoma fixtures was 97.9% after 1-year of follow-up. Eighty percent of the patients were fully satisfied with both aesthetic and functional outcome at the time of prosthetic insertion and at the 1-year follow-up. All reported data from the dentists, with the exception of one restoration with several abutment screw loosenings, scored from acceptable to excellent for the aesthetic and functional outcome of the treatment. The status of peri-implant mucosa was recorded as normal in approximately 60% of the sites. Plaque, when present, was more often detected on the palatal surfaces compared with the buccal surfaces.
This 1-year follow-up of Zygoma fixtures has shown good results with an acceptable number of minor complications and a majority of satisfied patients.
Despite refinements in surgical technique, including bone grafting and sophisticated prosthetic reconstructions, there are limitations to what can be achieved with bone-anchored fixed prostheses in ...patients with advanced atrophy of the maxillae. A new approach was suggested by a long-term study on onlay bone grafting and simultaneous placement of a fixture based on a new design: the zygoma fixture, and the aim of this study was to assess its potential. Twenty-eight consecutive patients with severely resorbed edentulous maxillae were included, 13 of whom had previously had multiple fixture surgery in the jawbone that had failed. A total of 52 zygoma fixtures and 106 conventional fixtures were installed. Bone grafting was deemed necessary in 17 patients. All patients have been followed for at least five years, and nine for up to 10 years. All patients were followed up with clinical and radiographic examinations, and in some cases rhinoscopy and sinoscopy as well. Three zygoma fixtures failed; two at the time of connection of the abutment and the third after six years. Of the conventional fixtures placed at the time of the zygoma fixture, 29 (27%) were lost. The overall prosthetic rehabilitation rate was 96% after at least five years of function. There were no signs of inflammatory reaction in the surrounding antral mucosa. Four patients with recurrent sinusitis recovered after inferior meatal antrostomy. To conclude, the zygoma fixture seems to be a valuable addition to our repertoire in the management of the compromised maxilla.
The present study reports on the late effects of increasing doses of radiation on the biomechanics of commercially pure titanium implants (fixtures) installed in the proximal tibia in 26 rats. Twelve ...weeks after various doses (10, 20, 30, and 35 Gy) of irradiation, the fixtures were inserted into rat tibiae, and after another eight weeks these were tested mechanically in vivo. Acute dose dependent skin reactions developed after all doses except 10 Gy, but most subsided within two to three weeks. There was a statistically significant reduction in torsion but the pull-out load was not significantly reduced for single doses up to 30 Gy. Histological analysis showed that bone remodelling was impaired. Shear stresses and shear moduli were estimated for the bone-implant interface and in the surrounding bone tissue. These estimated stresses and moduli were not found to be correlated to the dose of radiation.