A physiological sequence called autophagy qualitatively determines cellular viability by removing protein aggregates and damaged cyto-plasmic constituents, and contributes significantly to the degree ...of myocardial ischemia-reperfusion (I/R) injury. This tightly orchestrated cata-bolic cellular‘housekeeping’ process provides cells with a new source of energy to adapt to stressful conditions. This process was first described as a pro-survival mechanism, but increasing evidence suggests that it can also lead to the demise of the cell. Autophagy has been implicated in the pathogenesis of multiple cardiac conditions including myocardial I/R injury. However, a debate persists as to whether autophagy acts as a protec-tive mechanism or contributes to the injurious effects of I/R injury in the heart. This controversy may stem from several factors including the va-riability in the experimental models and species, and the methodology used to assess autophagy. This review provides updated knowledge on the modulation and role of autophagy in isolated cardiac cells subjected to I/R, and the growing interest towards manipulating autophagy to increase the survival of cardiac myocytes under conditions of stress-most notably being I/R injury. Perturbation of this evolutionarily conserved intracellular cleansing autophagy mechanism, by targeted modulation through, among others, mammalian target of rapamycin (mTOR) inhibitors, adenosine monophosphate-activated protein kinase (AMPK) modulators, calcium lowering agents, resveratrol, longevinex, sirtuin activators, the proapoptotic gene Bnip3, IP3 and lysosome inhibitors, may confer resistance to heart cells against I/R induced cell death. Thus, therapeutic ma-nipulation of autophagy in the challenged myocardium may benefit post-infarction cardiac healing and remodeling.
ABSTRACT
Background
Despite an inordinate share of health care resources being utilized by patients with kidney disease, morbidity and mortality in these patients remain high. Although renal biopsy ...is an intervention to identify potential treatment-modifiable causes of disease, large-scale data studying the safety and outcomes of percutaneous native kidney biopsy in hospitalized patients are lacking.
Methods
We queried the Nationwide Inpatient Sample database from 2008 to 2012 and identified all hospital admissions during which a percutaneous renal biopsy was performed. Patients <18 years of age or with a transplanted kidney were excluded. Data regarding associated renal pathology and procedure-related complications were collected and analyzed. Outcomes studied were length of stay, mortality and cost adjusted for inflation.
Results
A total of 118 064 hospital admissions were included in our analysis. The most common complications reported after percutaneous kidney biopsy were packed red blood cell transfusion (261/1000 cases), hematuria (129/1000 cases) and bleeding (78/1000 cases). Patients had an overall mortality of 1.8%. The mean length of stay for each hospitalization was 10.65 days, with a significant difference between elective and nonelective admissions (6.3 versus 11.7; P < 0.01). The average cost per hospitalization was US$22 917 after adjusting for inflation, again with a significant difference between elective and nonelective admissions (15 168 versus 24 780; P < 0.01).
Conclusion
Overall, percutaneous renal biopsy is considered a safe procedure; however, our study based on a national database demonstrates a relatively higher complication rate as compared with the limited prior available studies.
Deep insight into the complex mechanisms of myocardial ischemia-reperfusion injury has been attained in the past years. Minocycline is a second-generation tetracycline with US FDA approval for ...clinical use in various infections. Lately, several noninfectious cytoprotective activities of minocycline have been discovered as well. There now exists encouraging evidence of its protective role in cardiovascular pathology and its activity against myocardial ischemia-reperfusion injury. In this article, an overview of the major mechanisms involved in myocardial ischemia-reperfusion injury is presented. This is followed by an analysis of the mechanisms by which minocycline exerts its cytoprotective role and of studies that have been conducted in order to analyze minocycline, along with a review of the scope and limitations of its role as a cytoprotective agent.
With each successive year, the number of Emergency Department (ED) visits related to illicit drug abuse has progressively increased. Cocaine is the most common illegal drug to cause a visit to the ...ED. Cocaine use results in a variety of pathophysiological changes with regards to the cardiovascular system, such as constriction of coronary vessels, dysfunction of vascular endothelium, decreased aortic elasticity, hemodynamic disruptions, a hypercoagulable state, and direct toxicity to myocardial and vascular tissue. The clinical course of patients with cocaine-induced chest pain (CCP) is often challenging, and electrocardiographic findings can be potentially misleading in terms of diagnosing a myocardial infarction. In addition, there is no current satisfactory study regarding outcomes of use of various pharmacological drug therapies to manage CCP. At present, calcium-channel blockers and nitroglycerin are two pharmacological agents that are advocated as first-line drugs for CCP management, although the role of labetalol has been controversial and warrants further investigation. We performed an extensive search of available literature through a large number of scholarly articles previously published and listed on Index Medicus. In this review, we put forward a concise summary of the current approach to a patient presenting to the ED with CCP and management of the clinical scenario. The purpose of this review is to summarize the understanding of cocaine’s cardiovascular pathophysiology and to examine the current approach for proper evaluation and management of CCP.
We present a case of a 35-year-old male patient with a 12-hour history of sudden-onset, crushing chest pain and associated complaints of profuse diaphoresis, nausea and vomiting. The patient was ...transferred to our institution from an outside hospital for evaluation and possible emergent catheterization. Left heart catheterization was conclusive for normal coronary arteries and a ventriculogram revealed a left ventricular ejection fraction of approximately 45%. Due to a suspicion of myocarditis based on clinical history, pertinent serology tests were ordered, which were found to be negative. Cardiac magnetic resonance on delayed enhancement imaging showed typical sub-epicardial enhancement in a pattern most consistent with myocarditis. The patient was eventually diagnosed with myocarditis and discharged home later, without needing a myocardial biopsy. We present and discuss here the indications of myocardial biopsy and compare the relative utility of cardiac magnetic resonance imaging in formulating the diagnosis of myocarditis.
Automated insulin management features of the MiniMed
640G sensor-augmented pump system include suspension in response to predicted low sensor glucose (SG) values ("suspend before low"), suspension in ...response to existing low SG values ("suspend on low"), and automatic restarting of basal insulin delivery upon SG recovery. The effectiveness of these features was evaluated using CareLink
software data.
Anonymized data from MiniMed 640G system users (n = 4818), MiniMed 530G system users (n = 39,219), and MiniMed Paradigm
Veo™ system users (n = 43,193) who voluntarily uploaded pump and sensor data were retrospectively analyzed. Comparisons were made between days in which system features were enabled at any time and those in which they were not. Comparisons were also made between pump suspension events for which insulin delivery was automatically or manually resumed and between glycemic parameters of users who switched from the MiniMed Paradigm Veo system to the MiniMed 640G system.
Days in which the MiniMed 640G "suspend before low" feature was enabled had lower percentages of SG readings ≤70 mg/dL (3.9 mmol/L) or ≥240 mg/dL (13.3 mmol/L) than days when it was not enabled (P < 0.001 for each). Users who switched from the MiniMed Paradigm Veo system to the MiniMed 640G system had fewer excursions below ≤70 mg/dL (P < 0.001) and ≥240 mg/dL (P < 0.001). SG values following automatically resumed pump suspension events recovered more rapidly and had a more stabilized endpoint than following manually resumed events.
Automated insulin management features of the MiniMed 640G system can reduce the frequency of both high and low SG values and help stabilize SG after resumption of insulin delivery.
Real-world data from the first 3141 patients who completed 3 months of SmartGuard™ Auto Mode-enabled MiniMed™ 670G system use during the MiniMed 670G System Commercial Launch are reported. CareLink™ ...system data uploaded by real-world patients in the Commercial Launch from March 17, 2017 to December 31, 2017 were deidentified and analyzed. Comparisons of overall and night (10:00 PM-07:00 AM) time spent below, within, and above target glucose range (TIR) (70-180 mg/dL) between the baseline Manual Mode and closed-loop Auto Mode periods were made. These were evaluated alongside data from the 124 patients (aged 14-75 years) who completed the 3-month MiniMed 670G system pivotal trial (NCT 2463097), from June 2, 2015 to March 7, 2016. Real-world patients used Auto Mode a median 80.8% of the time (19 h and 24 min of the day). The overall mean of time spent in TIR was 66.0% during baseline Manual Mode versus 73.3% during Auto Mode (P < 0.001); the mean percentage of sensor glucose values <70 mg/dL was 2.7% versus 2.1% (P < 0.001); and that >180 mg/dL was 31.4% versus 24.6% (P < 0.001). The nighttime and early morning (03:00 AM-06:00 AM) TIR during Auto Mode was greater than that during baseline Manual Mode (nighttime: 77.2% vs. 67.4% P < 0.001, early morning: 70.9% vs. 84.6% P < 0.001). Similar differences between Manual Mode and Auto Mode TIR were observed across different age groups. A slight increase in total insulin delivered was also observed. Consistent with improved glycemic control demonstrated in the pivotal trial, analysis of CareLink system data from >3000 real-world patients who completed 3 months of Auto Mode-enabled MiniMed 670G system use demonstrated increased TIR and decreased time below and above TIR compared with baseline. These improved clinical outcomes were observed across a broad age range of patients with type 1 diabetes.
Inguinal hernia repair is one of the most frequently performed surgery. The ideal procedure for inguinal hernia repair remains controversial. Open Lichtenstein tension-free mesh repair (LMR) is one ...of the most preferred open techniques with satisfactory outcomes. Laparoscopic approach in inguinal hernia surgery remains controversial, especially in comparison with open procedures. In this study, we have reported a comparison of laparoscopic total extraperitoneal (TEP) inguinal hernia repair with LMR. Postoperative pain, operative time, complications like seroma, wound infection, chronic groin pain, and recurrence rate were parameters to evaluate the outcome. One hundred seventy-four patients were included in the study by consecutive randomized prospective sampling. The patients were divided into 2 groups: group A, laparoscopic TEP inguinal hernia repair, and group B, LMR. The procedures were performed by experienced surgeons. The primary outcomes were evaluated based on postoperative pain and recurrence rate. Secondary outcomes considered for evaluation were operative time, complications like seroma, infection, and chronic groin pain. Severe pain was reported in group A (7.9%) compared to group B (15.1%), which was statistically significant (P < .001). Moderate pain was reported more in group B (70.9%) compared to group A (29.5%) (P < .001). The mean operative time in group A was 84.6 ± 32.2, which was significantly higher than that in group B, 59.2 ± 14.8. There was no major complication in both groups. The chronic pain postoperatively was significantly in higher number of patients in group B vs group A (22.09% vs 3.4%). The postoperative hospital stay period was significantly lesser for group A vs for group B (2.68 ± 1.52 vs 3.86 ± 6.16). Time duration taken to resume normal activities was significantly lower in group A (13.6 ± 6.8) vs (19.8 ± 4.6) in group B (P < .001). Although there is definite evidence of longer operative time and learning curve, laparoscopic TEP has added advantages like less postoperative pain, early resumption of normal activities, less chronic groin pain, and comparable recurrence rate compared to open Lichtenstein repair. Laparoscopic TEP can be performed with acceptable outcomes and less postoperative complications if performed by experienced hands.