With the development of reliable endoscopic closure techniques and tools, endoscopic full-thickness resection (EFTR) is emerging as a therapeutic option for the treatment of subepithelial tumors and ...epithelial neoplasia with significant fibrosis. EFTR may be categorized as “exposed” and “nonexposed.” In exposed EFTR, the full-thickness resection is undertaken with a tunneled or nontunneled technique, with subsequent closure of the defect. In nonexposed EFTR, a secure serosa-to-serosa apposition is achieved before full-thickness resection of the isolated lesion. This document reviews current techniques and devices used for EFTR and reviews clinical applications and outcomes.
Devices for endoscopic hemostasis of nonvariceal GI bleeding (with videos) Parsi, Mansour A., MD, MPH, FASGE; Schulman, Allison R., MD, MPH; Aslanian, Harry R., MD, FASGE ...
VideoGIE : an official video journal of the American Society for Gastrointestinal Endoscopy,
07/2019, Letnik:
4, Številka:
7
Journal Article
Recenzirano
Odprti dostop
BackgroundEndoscopic intervention is often the first line of therapy for GI nonvariceal bleeding. Although some of the devices and techniques used for this purpose have been well studied, others are ...relatively new, with few available outcomes data.MethodsIn this document, we review devices and techniques for endoscopic treatment of nonvariceal GI bleeding, the evidence regarding their efficacy and safety, and financial considerations for their use.ResultsDevices used for endoscopic hemostasis in the GI tract can be classified into injection devices (needles), thermal devices (multipolar/bipolar probes, hemostatic forceps, heater probe, argon plasma coagulation, radiofrequency ablation, and cryotherapy), mechanical devices (clips, suturing devices, banding devices, stents), and topical devices (hemostatic sprays).ConclusionsEndoscopic evaluation and treatment remains a cornerstone in the management of nonvariceal upper- and lower-GI bleeding. A variety of devices is available for hemostasis of bleeding lesions in the GI tract. Other than injection therapy, which should not be used as monotherapy, there are few compelling data that strongly favor any one device over another. For endoscopists, the choice of a hemostatic device should depend on the type and location of the bleeding lesion, the availability of equipment and expertise, and the cost of the device.
Background and Aims Endoscopic real-time imaging of Barrett’s esophagus (BE) with advanced imaging technologies enables targeted biopsies and may eliminate the need for random biopsies to detect ...dysplasia during endoscopic surveillance of BE. This systematic review and meta-analysis was performed by the American Society for Gastrointestinal Endoscopy (ASGE) Technology Committee to specifically assess whether acceptable performance thresholds outlined by the ASGE Preservation and Incorporation of Valuable Endoscopic Innovations (PIVI) document for clinical adoption of these technologies have been met. Methods We conducted meta-analyses calculating the pooled sensitivity, negative predictive value (NPV), and specificity for chromoendoscopy by using acetic acid and methylene blue, electronic chromoendoscopy by using narrow-band imaging, and confocal laser endomicroscopy (CLE) for the detection of dysplasia. Random effects meta-analysis models were used. Statistical heterogeneity was evaluated by means of I2 statistics. Results The pooled sensitivity, NPV, and specificity for acetic acid chromoendoscopy were 96.6% (95% confidence interval CI, 95-98), 98.3% (95% CI, 94.8-99.4), and 84.6% (95% CI, 68.5-93.2), respectively. The pooled sensitivity, NPV, and specificity for electronic chromoendoscopy by using narrow-band imaging were 94.2% (95% CI, 82.6-98.2), 97.5% (95% CI, 95.1-98.7), and 94.4% (95% CI, 80.5-98.6), respectively. The pooled sensitivity, NPV, and specificity for endoscope-based CLE were 90.4% (95% CI, 71.9-97.2), 98.3% (95% CI, 94.2-99.5), and 92.7% (95% CI, 87-96), respectively. Conclusions Our meta-analysis indicates that targeted biopsies with acetic acid chromoendoscopy, electronic chromoendoscopy by using narrow-band imaging, and endoscope-based CLE meet the thresholds set by the ASGE PIVI, at least when performed by endoscopists with expertise in advanced imaging techniques. The ASGE Technology Committee therefore endorses using these advanced imaging modalities to guide targeted biopsies for the detection of dysplasia during surveillance of patients with previously nondysplastic BE, thereby replacing the currently used random biopsy protocols.
Biliary and pancreatic lithotripsy devices Watson, Rabindra R., MD; Parsi, Mansour A., MD, MPH, FASGE; Aslanian, Harry R., MD, FASGE ...
VideoGIE : an official video journal of the American Society for Gastrointestinal Endoscopy,
11/2018, Letnik:
3, Številka:
11
Journal Article
Recenzirano
Odprti dostop
Background and Aims Lithotripsy is a procedure for fragmentation or destruction of stones to facilitate their removal or passage from the biliary or pancreatic ducts. Although most stones may be ...removed endoscopically using conventional techniques such as endoscopic sphincterotomy in combination with balloon or basket extraction, lithotripsy may be required for clearance of large, impacted, or irregularly shaped stones. Several modalities have been described, including intracorporeal techniques such as mechanical lithotripsy (ML), electrohydraulic lithotripsy (EHL), and laser lithotripsy, as well as extracorporeal shock-wave lithotripsy (ESWL). Methods In this document, we review devices and methods for biliary and pancreatic lithotripsy and the evidence regarding efficacy, safety, and financial considerations. Results Although many difficult stones can be safely removed using ML, endoscopic papillary balloon dilation (EPBD) has emerged as an alternative that may lessen the need for ML and also reduce the rate of adverse events. EHL and laser lithotripsy are effective at ductal clearance when conventional techniques are unsuccessful, although they usually require direct visualization of the stone by the use of cholangiopancreatoscopy and are often limited to referral centers. ESWL is effective but often requires coordination with urologists and the placement of stents or drains with subsequent procedures for extracting stone fragments and, thus, may be associated with increased costs. Conclusions Several lithotripsy techniques have been described that vary with respect to ease of use, generalizability, and cost. Overall, lithotripsy is a safe and effective treatment for difficult biliary and pancreatic duct stones.
Background Challenges in EUS-guided FNA (EUS-FNA) include sampling error, nondiagnostic cytology, and limited on-site cytological evaluation. A prototype needle-based confocal laser endomicroscopy ...(nCLE) probe is a submillimeter probe that provides real-time imaging at the microscopic level through the FNA needle. Objective To evaluate the feasibility of nCLE during EUS-FNA of pancreatic lesions. Design Feasibility study. Setting Multicenter, tertiary care. Patients Eighteen patients presenting for EUS-FNA. Interventions Patients were injected with 2.5 mL of 10% fluorescein. The lesion was interrogated with the nCLE probe positioned at the tip of a 19-gauge FNA needle. Main Outcome Measurements Device integrity, technical ease, safety, and image acquisition. Results Cases included 16 cysts and 2 masses. There were no device malfunctions. Technical challenges were encountered in 6 of 18 attempts to image and reflected challenges with a postloading technique, the longer ferule tip, and a transduodenal approach. Technical feasibility to perform imaging with nCLE during a pancreatic EUS-FNA procedure was achieved in 17 of 18 cases. Ten cases had good to very good image quality. Two serious adverse events occurred; both were pancreatitis requiring hospitalization. Limitations Limited sample size, small number of patients with confirmed pathological diagnosis, lack of coregistered pathology and images. Conclusions nCLE in the pancreas is technically feasible via a 19-gauge needle under endosonographic guidance. Future studies will address identification of structures, diagnostic accuracy, and complication profiles. The rate of pancreatitis needs to be further clarified and mitigated.
Background There is a lack of prospective, randomized studies comparing the diagnostic yield and complication rates of 22-gauge and 25-gauge needles during EUS-FNA of solid pancreatic masses. ...Objectives Our primary aim was to compare the diagnostic yield of 22-gauge and 25-gauge needles. Secondary aims included determining the number of needle passes performed, ease of needle passage, and complications. Design Prospective, randomized study. Setting Tertiary referral centers at Yale University School of Medicine, New Haven, Connecticut, and Virginia Piper Cancer Institute, Minneapolis, Minnesota. Patients Patients with a suspected solid pancreatic mass from February 2007 to June 2008 were enrolled. Interventions Patients were randomized to EUS-FNA with a 22-gauge or 25-gauge needle. Main Outcome Measurements A diagnostic result was defined as cytology findings positive for malignant cells. Results A total of 131 patients were enrolled: EUS-FNA was performed with a 22-gauge needle in 64 patients and with a 25-gauge needle in 67 patients. Cytology was diagnostic in 120 (91.6%) of 131 patients overall: 56 (87.5%) of 64 with 22-gauge needles and 64 (95.5%) of 67 with 25-gauge needles (no statistically significant difference was found between the 2 groups; P =.18). A similar number of passes was performed in both arms (mean SD 2.6 1.2 each; P =.96). There were no complications in either group. Limitation A larger number of patients is needed to determine small differences in diagnostic yield. Conclusions This is the first prospective, randomized trial comparing 22-gauge and 25-gauge needles in EUS-FNA of solid pancreatic masses. We achieved equally high diagnostic yields by using a similar number of passes, showing that 25-gauge needles are an effective alternative to 22-gauge needles.