1.
  • Impact of calibrator concen... Impact of calibrator concentrations and their distribution on accuracy of quadratic regression for liquid chromatography–mass spectrometry bioanalysis
    Tan, Aimin; Awaiye, Kayode; Trabelsi, Fethi Analytica chimica acta, 03/2014, Letnik: 815
    Journal Article
    Recenzirano

    •Different calibrators have different impacts on accuracy of quadratic regression.•The lowest & highest concentrations plus their geometric mean are three critical ones.•Using these critical ...
Celotno besedilo
Dostopno za: UL
2.
  • Some unnecessary or inadequ... Some unnecessary or inadequate common practices in regulated LC-MS bioanalysis
    Tan, Aimin; Awaiye, Kayode; Trabelsi, Fethi Bioanalysis, 10/2014, Letnik: 6, Številka: 20
    Journal Article
    Recenzirano

    The global bioanalytical community increasingly craves scientifically sound practices and guidance where the rationale is given for each requirement. To this end, it is critical to first evaluate all ...
Celotno besedilo
3.
  • Comparison of different lin... Comparison of different linear calibration approaches for LC–MS bioanalysis
    Tan, Aimin; Awaiye, Kayode; Jose, Besy ... Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, 12/2012, Letnik: 911
    Journal Article
    Recenzirano

    ► Two-concentration linear calibration is better than multi-concentration one. ► One curve may have more failed runs and higher variation at low end than two curves. ► A new in-between approach is ...
Celotno besedilo
Dostopno za: UL
4.
  • Comparison of two-concentra... Comparison of two-concentration with multi-concentration linear regressions: Retrospective data analysis of multiple regulated LC–MS bioanalytical projects
    Musuku, Adrien; Tan, Aimin; Awaiye, Kayode ... Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, 09/2013, Letnik: 934
    Journal Article
    Recenzirano

    •Two-concentration linear regression is reliable for regulated LC–MS bioanalysis.•Two-concentration linear regression can typically save 15–20% of time and cost.•A minimum of six different ...
Celotno besedilo
Dostopno za: UL
5.
  • Comparison of two-concentra... Comparison of two-concentration with multi-concentration linear regressions: Retrospective data analysis of multiple regulated LCaMS bioanalytical projects
    Musuku, Adrien; Tan, Aimin; Awaiye, Kayode ... Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, 09/2013, Letnik: 934
    Journal Article
    Recenzirano

    Linear calibration is usually performed using eight to ten calibration concentration levels in regulated LCaMS bioanalysis because a minimum of six are specified in regulatory guidelines. However, we ...
Celotno besedilo
Dostopno za: UL
6.
  • Comparison of different lin... Comparison of different linear calibration approaches for LCaMS bioanalysis
    Tan, Aimin; Awaiye, Kayode; Jose, Besy ... Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, 12/2012, Letnik: 911
    Journal Article
    Recenzirano

    Many different calibration approaches are used for linear calibration in LCaMS bioanalysis, such as different numbers of concentration levels and replicates. However, direct comparison of these ...
Celotno besedilo
Dostopno za: UL
7.
  • Large-scale retrospective e... Large-scale retrospective evaluation of regulated liquid chromatography–mass spectrometry bioanalysis projects using different total error approaches
    Tan, Aimin; Saffaj, Taoufiq; Musuku, Adrien ... Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, 03/2015, Letnik: 983-984
    Journal Article
    Recenzirano

    •Large-scale retrospective evaluation of GLP projects using total error approaches.•Comparison of different total error approaches using real data of GLP projects.•Risks of accepting unacceptable ...
Celotno besedilo
Dostopno za: UL
8.
  • 12th GCC Closed Forum: crit... 12th GCC Closed Forum: critical reagents; oligonucleotides; CoA; method transfer; HRMS; flow cytometry; regulatory findings; stability and immunogenicity
    Briscoe, Chad; Hughes, Nicola; Hayes, Roger ... Bioanalysis, 06/2019, Letnik: 11, Številka: 12
    Journal Article
    Recenzirano
    Odprti dostop

    The 12th GCC Closed Forum was held in Philadelphia, PA, USA, on 9 April 2018. Representatives from international bioanalytical Contract Research Organizations were in attendance in order to discuss ...
Celotno besedilo

PDF
9.
  • Recommendations on incurred... Recommendations on incurred sample stability (ISS) by GCC
    Lowes, Steve; LeLacheur, Richard; Shoup, Ronald ... Bioanalysis, 09/2014, Letnik: 6, Številka: 18
    Journal Article
    Recenzirano
    Odprti dostop

    The topic of incurred sample stability (ISS) has generated considerable discussion within the bioanalytical community in recent years. The subject was an integral part of the seventh annual Workshop ...
Celotno besedilo

PDF
10.
  • The 10th GCC Closed Forum: ... The 10th GCC Closed Forum: rejected data, GCP in bioanalysis, extract stability, BAV, processed batch acceptance, matrix stability, critical reagents, ELN and data integrity and counteracting fraud
    Cape, Stephanie; Islam, Rafiq; Nehls, Corey ... Bioanalysis, 2017-April-01, 2017-Apr, 2017-04-00, Letnik: 9, Številka: 7
    Journal Article
    Recenzirano
    Odprti dostop

    The 10th Global CRO Council (GCC) Closed Forum was held in Orlando, FL, USA on 18 April 2016. In attendance were decision makers from international CRO member companies offering bioanalytical ...
Celotno besedilo

PDF