The role of traditional media and the Internet in relation to young people’s political participation has attracted a great deal of scholarly attention. Starting from a notion of differential media ...use and an encompassing notion of political participation, this article tests the relationships between media use (newspaper, television, and Internet) and offline and online forms of political participation. Findings from a national survey (n = 2,409, age 16 to 24) reveal that a variety of Internet uses are positively related with different forms of political participation, whereas the relationship between most uses of traditional media and participation are weak, albeit positive. The study rejects the predictive power of duration of media use but finds support for the type of media use. Positive relationships between online communication and noninformational uses of the Internet vis-à-vis participation are found. The research demonstrates how a wider and more contemporary conception of political participation, together with more detailed measures of media use, can help to gain better insight in the roles media can play in affecting participatory behavior among the Internet generation.
Clinical diagnosis of early melanoma (Breslow thickness less than 0.8 mm) is crucial to disease-free survival. However, it is subjective and can be exceedingly difficult, leading to missed melanomas, ...or unnecessary excision of benign pigmented skin lesions. An objective technique is needed to improve the diagnosis of early melanoma.
We have developed a method to improve diagnosis of (thin) melanoma, based on Raman spectroscopy. In an ex vivo study in a tertiary referral (pigmented lesions) centre, high-wavenumber Raman spectra were collected from 174 freshly excised melanocytic lesions suspicious for melanoma. Measurements were performed on multiple locations within the lesions. A diagnostic model was developed and validated on an independent data set of 96 lesions.
Approximately 60% of the melanomas included in this study were melanomas in situ. The invasive melanomas had an average Breslow thickness of 0.89 mm. The diagnostic model correctly classified all melanomas (including in situ) with a specificity of 43.8%, and showed a potential improvement of the number needed to treat from 6.0 to 2.7, at a sensitivity of 100%.
This work signifies an important step towards accurate and objective clinical diagnosis of melanoma and in particular melanoma with Breslow thickness <0.8 mm.
Melanoma is a pigmented type of skin cancer, which has the highest mortality of all skin cancers. Because of the low clinical diagnostic accuracy for melanoma, an objective tool is needed to assist ...clinical assessment of skin lesions that are suspected of (early) melanoma. The aim of this study was to identify spectral differences in the CH region of HWVN (high-wavenumber) Raman spectra between melanoma and benign melanocytic lesions clinically suspected of melanoma. We used these spectral differences to explore preliminary classification models to distinguish melanoma from benign melanocytic lesions. Data from 82 freshly excised melanocytic lesions clinically suspected of melanoma were measured using an in-house built Raman spectrometer, which has been optimized for measurements on pigmented skin lesions (excitation wavelength 976 nm and a wavelength range of the Raman signal 1340–1540 nm). Clear spectral differences were observed between melanoma and benign melanocytic lesions. These differences can be assigned mainly to the symmetric CH2 stretching vibrations of lipids. Our results show that the Raman bands between 2840 and 2930 cm–1 have increased intensity for melanoma when compared to benign melanocytic lesions, suggesting an increase in lipid content in melanoma. These results demonstrate that spectroscopic information in the CH-stretching region of HWVN Raman spectra can discriminate melanoma from benign melanocytic lesions that are often clinically misdiagnosed as melanoma and that Raman spectroscopy has the potential to provide an objective clinical tool to improve the clinical diagnostic accuracy of skin lesions suspected of melanoma.
•Depth of invasion (DOI) is associated with lymph node metastasis in oral cancer (OC).•The AJCC (8th edition) definition of DOI in OC is recommended.•DOI ≥ 4 mm is an accurate cut-off value for ...elective neck dissection (END).•END performed for patients with DOI ≥ 4 mm results in lower regional recurrence.
Depth of invasion (DOI) is the most important predictor for lymph node metastasis (LNM) in early stage (T1-T2) oral cancer. The aim of this study is to validate the cut-off value of 4 mm on which the decision to perform an Elective Neck Dissection (END) is made.
We performed a retrospective study in patients with pathologically proven early stage oral cavity squamous cell carcinoma (OCSCC) without clinical or radiological signs of LNM, who were treated between 2013 and 2018. An END was performed when DOI was ≥ 4 mm and a watchful waiting protocol was applied in patients with DOI < 4 mm.
Three hundred patients were included. END was performed in 77% of patients with DOI ≥ 4 mm, of which 36% had occult LNM (pN+). Patients in the watchful waiting group (48%) developed a regional recurrence in 5.2% for DOI < 4 mm and 24.1% for DOI ≥ 4 mm. For DOI ≥ 4 mm, regional recurrence free survival was higher for patients who were treated with END compared to watchful waiting (p = 0.002). A Receiver-Operator-Curve -analysis showed that a DOI cut-off value of 4.0 mm was the optimal threshold for the prediction of occult LNM (95.1% sensitivity, 52.9% specificity).
A DOI of ≥ 4 mm is an accurate cut-off value for performing an END in early stage OCSCC. END results in higher survival rates and lower regional recurrence rates in patients with DOI ≥ 4 mm.
We have developed a method to determine the limit of detection (LoD) for quantitative measurement of exogenous analytes in the outer layer of the human skin by in vivo confocal Raman spectroscopy. ...The method is in accordance with the guidelines of the International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use that have been adopted by regulatory authorities such as the American Food and Drug Administration and the European Medicines Agency. The method can be applied in silico so that the limit of detection can be assessed before starting a skin penetration study, for example, in areas of pharmaceutical formulation, pharmacokinetics, or toxicokinetics. This can significantly reduce the need for expensive and time-consuming feasibility studies. This paper describes the method to calculate this LoD as well as the experimental and methodological factors that can influence the calculation of the LoD.
The poor prognosis of oral cavity squamous cell carcinoma (OCSCC) patients is associated with residual tumor after surgery. Raman spectroscopy has the potential to provide an objective ...intra-operative evaluation of the surgical margins. Our aim was to understand the discriminatory basis of Raman spectroscopy at a histological level. In total, 127 pseudo-color Raman images were generated from unstained thin tissue sections of 25 samples (11 OCSCC and 14 healthy) of 10 patients. These images were clearly linked to the histopathological evaluation of the same sections after hematoxylin and eosin-staining. In this way, Raman spectra were annotated as OCSCC or as a surrounding healthy tissue structure (i.e., squamous epithelium, connective tissue (CT), adipose tissue, muscle, gland, or nerve). These annotated spectra were used as input for linear discriminant analysis (LDA) models to discriminate between OCSCC spectra and healthy tissue spectra. A database was acquired with 88 spectra of OCSCC and 632 spectra of healthy tissue. The LDA models could distinguish OCSCC spectra from the spectra of adipose tissue, nerve, muscle, gland, CT, and squamous epithelium in 100%, 100%, 97%, 94%, 93%, and 75% of the cases, respectively. More specifically, the structures that were most often confused with OCSCC were dysplastic epithelium, basal layers of epithelium, inflammation- and capillary-rich CT, and connective and glandular tissue close to OCSCC. Our study shows how well Raman spectroscopy enables discrimination between OCSCC and surrounding healthy tissue structures. This knowledge supports the development of robust and reliable classification algorithms for future implementation of Raman spectroscopy in clinical practice.
Patients with oral cavity cancer are almost always treated with surgery. The goal is to remove the tumor with a margin of more than 5 mm of surrounding healthy tissue. Unfortunately, this is only ...achieved in about 15% to 26% of cases. Intraoperative assessment of tumor resection margins (IOARM) can dramatically improve surgical results. However, current methods are laborious, subjective, and logistically demanding. This hinders broad adoption of IOARM, to the detriment of patients. Here we present the development and validation of a high-wavenumber Raman spectroscopic technology, for quick and objective intraoperative measurement of resection margins on fresh specimens. It employs a thin fiber-optic needle probe, which is inserted into the tissue, to measure the distance between a resection surface and the tumor. A tissue classification model was developed to discriminate oral cavity squamous cell carcinoma (OCSCC) from healthy oral tissue, with a sensitivity of 0.85 and a specificity of 0.92. The tissue classification model was then used to develop a margin length prediction model, showing a mean difference between margin length predicted by Raman spectroscopy and histopathology of −0.17 mm.
Raman spectroscopic technology for quick and accurate assessment of tumor resection margins.
Near-infrared (NIR) fluorescence imaging using exogenous fluorescent agents provides whole-field images in real-time to assist the surgeon in the excision of a tumor. Although the method has high ...sensitivity, the specificity can sometimes be lower than expected. Raman spectroscopy can detect tumors with high specificity. Therefore, a combination of both techniques can be advantageous. A complication that must be addressed is that the NIR spectral region is favored by both techniques for (
in vivo
) tissue analysis. When fluorescence and Raman emissions spectrally overlap, it becomes challenging or impossible to detect the Raman signal. In this paper, by avoiding this overlap, we describe a Raman spectroscopy setup capable of recording high-quality Raman spectra from tissue containing NIR exogenous fluorescent agents. We identify an optimal wavelength interval (900-915 nm) for Raman excitation, which avoids both excitation of fluorescent dyes and Raman signal self-absorption by the tissue. In this way, Raman spectroscopy can be combined with the currently most-used NIR fluorescent dyes. This combined novel setup could pave the way for clinical trials benefiting from both fluorescence imaging and Raman spectroscopy to avoid positive margins in cancer surgery.
Combination of intraoperative wide-field fluorescence imaging and Raman spectroscopy aiding in tumor border identification.