Abstract It is challenging to make nocturnal observations of the natural behaviour of flower‐visiting moths as they are highly sensitive to visible artificial light sources. One solution, implemented ...here, is to use specially‐adapted close‐focusing camera traps that rely on infrared wavelengths for detection and illumination of small insect subjects. We investigated the pollination system of Bonatea saundersiodes , a rare African terrestrial orchid that is phylogenetically nested in the large Habenaria clade. We used modified camera traps and direct observations to study the pollination system of B. saundersioides . We quantified floral traits, including morphology, nectar, spectral reflectance and scent chemistry. Flowers of this orchid species were found to be pollinated exclusively by settling noctuid moths. Moth visits to the orchid were recorded throughout the night, with peaks of activity after dusk and just before dawn. Pollinaria of the orchid are attached between the palps of visiting moths. Floral traits generally consistent with settling moth pollination include the relatively short floral spurs (ca. 20 mm) containing small amounts of nectar, white and green perianth segments, and the floral scent which is produced at night and is dominated by β‐ocimene and other terpenoid compounds. This study demonstrates that close‐focusing camera traps have tremendous potential to improve our understanding of plant–pollinator interactions which are not easy to study using traditional methods.
Purpose
It is well established that thyroiditis and other thyroid disorders can be induced by COVID-19 infection, but there is limited information about the autoimmune/inflammatory syndrome induced ...by adjuvants (ASIA) after severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) vaccination. We report two cases of thyrotoxicosis following SARS-CoV-2 vaccine.
Methods and results
Two young health care peoples (wife and husband) received a first dose of SARS-CoV-2 vaccine, and few weeks later developed clinical manifestations of thyroid hyperactivity, with increased thyroid hormone levels on thyroid function tests, suppressed thyroid-stimulating hormone and negative antithyroid antibodies, despite being healthy before vaccination. They were diagnosed at the 4th week after first dose of SARS-Cov-2 vaccine as silent thyroiditis and followed without treatment, since their symptoms were not severe. At the 6th week, the patients became wholly asymptomatic and their thyroid function returned to normal.
Conclusions
Thyrotoxicosis can occur after SARS-CoV-2 vaccination probably related to silent thyroiditis.
Purpose
Purpose of this study was to retrospectively review our experience of multidisciplinary clinic providing a joint approach by radiation oncologist and anesthetist for patients with cancer pain ...to evaluate the adequacy and the IMprovement in MAnagement (IM-MA study) of this symptom.
Methods
A Team for Pain Management (TPM) represented by radiation oncologist and anesthetist weekly provided consultations to patient presenting cancer pain. TPM prospectively reported epidemiologic, symptomatic, and pharmacological data. TPM modified pain therapy and indicated antalgic radiotherapy. Patients were evaluated at baseline and after 4 weeks after intervention.
Results
From November 2015 to April 2016, 65 patients were evaluated by TPM. At the baseline, 18 patients (27.7%) were undertreated (i.e., receiving inadequate pain management); furthermore, 27 patients (41.5%) despite receiving strong opioids had uncontrolled pain. After 4 weeks from intervention, undertreated patients were reduced to 1.53%. For those patients undergone to radiotherapy, response at 34 weeks was scored as follows: complete response 28.8%, partial response 46.7%, pain progression 0.95%, indeterminate response 23.8%.
Conclusions
A multidisciplinary Team for Pain Management improved the clinical management, optimizing pain control and increasing adequacy of pharmacological management. The TPM intervention seems particularly worth for patients presenting specific features including BTcP, neuropathic pain, severe pain due to bone metastases, and any potential candidate to radiotherapy. Larger series and QoL questionnaires are required to confirm these results.
The glioblastoma's bad prognosis is primarily due to intra-tumor heterogeneity, demonstrated from several studies that collected molecular biology, cytogenetic data and more recently radiomic ...features for a better prognostic stratification. The GLIFA project (GLIoblastoma Feature Analysis) is a multicentric project planned to investigate the role of radiomic analysis in GB management, to verify if radiomic features in the tissue around the resection cavity may guide the radiation target volume delineation.
We retrospectively analyze from three centers radiomic features extracted from 90 patients with total or near total resection, who completed the standard adjuvant treatment and for whom we had post-operative images available for features extraction. The Manual segmentation was performed on post gadolinium T1w MRI sequence by 2 radiation oncologists and reviewed by a neuroradiologist, both with at least 10 years of experience. The Regions of interest (ROI) considered for the analysis were: the surgical cavity ± post-surgical residual mass (CTV_cavity); the CTV a margin of 1.5 cm added to CTV_cavity and the volume resulting from subtracting the CTV_cavity from the CTV was defined as CTV_Ring. Radiomic analysis and modeling were conducted in RStudio. Z-score normalization was applied to each radiomic feature. A radiomic model was generated using features extracted from the Ring to perform a binary classification and predict the PFS at 6 months. A 3-fold cross-validation repeated five times was implemented for internal validation of the model.
Two-hundred and seventy ROIs were contoured. The proposed radiomic model was given by the best fitting logistic regression model, and included the following 3 features: F_cm_merged.contrast, F_cm_merged.info.corr.2, F_rlm_merged.rlnu. A good agreement between model predicted probabilities and observed outcome probabilities was obtained (
-value of 0.49 by Hosmer and Lemeshow statistical test). The ROC curve of the model reported an AUC of 0.78 (95% CI: 0.68-0.88).
This is the first hypothesis-generating study which applies a radiomic analysis focusing on healthy tissue ring around the surgical cavity on post-operative MRI. This study provides a preliminary model for a decision support tool for a customization of the radiation target volume in GB patients in order to achieve a margin reduction strategy.
Purpose:
Results about the feasibility of a method for quasi real timein vivo dosimetry (IVD) at the isocenter point for volumetric modulated arc therapy (VMAT) are here reported. The method is based ...on correlations between the EPID signal and the dose on the beam central axis. Moreover, the γ-analysis of EPID images was adopted to verify off-axis reproducibility of fractionated plan delivery.
Methods:
An algorithm to reconstructin vivo the isocenter dose, Diso, for RapidArc treatments has been developed. 20 VMAT plans, optimized with two opposite arcs, for prostate, pancreas, and head treatments have been delivered by a Varian linac both to a conic PMMA phantom with elliptical section and to patients. The ratios R between reconstructed Diso and the planned doses were determined for phantom and patient irradiations adopting an acceptance criterion of ±5%. In total, 40 phantom checks and 400 patient checks were analyzed. Moreover, 3% and 3 mm criteria were adopted for portal image γ-analysis to assess patient irradiation reproducibility.
Results:
The average ratio R, between reconstructed and planned doses for the PMMA phantom irradiations was equal to 1.007 ± 0.024. When the IVD method was applied to the 20 patients, the average R ratio was equal to 1.003 ± 0.017 and 96% of the tests were within the acceptance criteria. The portal image γ-analysis supplied 88% of the tests within the pass rates γmean ≤ 0.4 and Pγ<1 ≥ 98%. All the warnings were understood comparing the CT and the cone beam CT images and in one case a patient's setup error was detected and corrected for the successive fractions.
Conclusions:
This preliminary experience suggests that the method is able to detect dosimetric errors in quasi real time at the end of the therapy session. The authors intend to extend this procedure to other pathologies with the integration of in-room imaging verification by cone beam CT.
Abstract Purpose This study was planned to clarify the optimal treatment for squamous cell carcinoma of the rectum, an histological entity extremely rare. Methods Ten patients with histologically ...proven squamous cell carcinoma of the rectum were treated with concomitant radiochemotherapy. Radiation therapy was delivered with a 3Dconformational multiple field technique to a dose ranging from 45 to 76.5 Gy, with 6–15 MV energy photons. Chemotherapy consisted of an antimetabolite drug in association with mitomycin C or oxaliplatin. Overall survival and disease free survival were considered in months from the end of the concomitant treatment. Results All patients completed programmed radiochemotherapy treatment but two patients were excluded to the analysis. Six patients (75%) presented negative biopsy 6 months after the end of radiochemotherapy. Seven patients (87.5%) showed a tumour regression after initial treatment. Only 1 patient underwent salvage surgery. Considering a mean follow-up of 41.75 months, 7 patients are still disease free survivors. Only 1 patient developed local recurrence at 6 months and he died 14 months after abdomino-perineal resection. Conclusion Primary radio chemotherapy, with a curative intent, could be considered the treatment modality of choice for squamous carcinoma of the rectum.