Abstract Context Prostate biopsy (PB) represents the gold standard method to confirm the presence of cancer. In addition to traditional random or systematic approaches, a magnetic resonance imaging ...(MRI)–guided technique has been introduced recently. Objective To perform a systematic review of complications after transrectal ultrasound (TRUS)–guided, transperineal, and MRI-guided PB. Evidence acquisition We performed a systematic literature search of Web of Science, Embase, and Scopus databases up to October 2015, according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. Complications and mortality following random, systematic, and image-guided PBs were reviewed. Eighty-five references were included. Evidence synthesis The most frequent complication after PB was minor and self-limiting bleeding (hematuria and hematospermia), regardless of the biopsy approach. Occurrence of rectal bleeding was comparable for traditional TRUS-guided and image-guided PBs. Almost 25% of patients experienced lower urinary tract symptoms, but only a few had urinary retention, with higher rates after a transperineal approach. Temporary erectile dysfunction was not negligible, with a return to baseline after 1–6 mo. The incidence of infective complications is increasing, with higher rates among men with medical comorbidities and older age. Transperineal and in-bore MRI–targeted biopsy may reduce the risk of severe infectious complications. Mortality after PB is uncommon, regardless of biopsy technique. Conclusions Complications after PB are frequent but often self-limiting. The incidence of hospitalization due to severe infections is continuously increasing. The patient's general health status, risk factors, and likelihood of antimicrobial resistance should be carefully appraised before scheduling a PB. Patient summary We reviewed the variety and incidence of complications after prostate biopsy. Even if frequent, complications seldom represent a problem for the patient. The most troublesome complications are infections. To minimize this risk, the patient's medical condition should be carefully evaluated before biopsy.
Objectives This study sought to assess device-specific outcomes after implantation of bare-metal stents (BMS), zotarolimus-eluting Endeavor Sprint stents (ZES-S), paclitaxel-eluting stents (PES), ...or everolimus-eluting stents (EES) (Medtronic Cardiovascular, Santa Rosa, California) in all-comer patients undergoing percutaneous coronary intervention. Background Few studies have directly compared second-generation drug-eluting stents with each other or with BMS. Methods We randomized 2,013 patients to BMS, ZES-S, PES, or EES implantation. At 30 days, each stent group received up to 6 or 24 months of clopidogrel therapy. The key efficacy endpoint was the 2-year major adverse cardiac event (MACE) including any death, myocardial infarction, or target vessel revascularization, whereas the cumulative rate of definite or probable stent thrombosis (ST) was the key safety endpoint. Results Clinical follow-up at 2 years was complete for 99.7% of patients. The MACE rate was lowest in EES (19.2%; 95% confidence interval CI: 16.0 to 22.8), highest in BMS (32.1%; 95% CI: 28.1 to 36.3), and intermediate in PES (26.2%; 95% CI: 22.5 to 30.2) and ZES-S (27.8%; 95% CI: 24.1 to 31.9) groups (chi-square test = 18.9, p = 0.00029). The 2-year incidence of ST in the EES group (1%; 95% CI: 0.4 to 2.2) was similar to that in the ZES-S group (1.4%; 95% CI: 0.7 to 2.8), whereas it was lower compared with the PES (4.6%, 95% CI: 3.1 to 6.8) and BMS (3.6%; 95% CI: 2.4 to 5.6) groups (chi-square = 16.9; p = 0.0001). Conclusions Our study shows that cumulative MACE rate, encompassing both safety and efficacy endpoints, was lowest for EES, highest for BMS, and intermediate for PES and ZES-S groups. EES outperformed BMS also with respect to the safety endpoints with regard to definite or probable and definite, probable, or possible ST. (PROlonging Dual antiplatelet treatment after Grading stent-induced Intimal hyperplasia studY PRODIGY; NCT00611286 )
All-optical approaches to particle acceleration are currently attracting a significant research effort internationally. Although characterized by exceptional transverse and longitudinal emittance, ...laser-driven ion beams currently have limitations in terms of peak ion energy, bandwidth of the energy spectrum and beam divergence. Here we introduce the concept of a versatile, miniature linear accelerating module, which, by employing laser-excited electromagnetic pulses directed along a helical path surrounding the laser-accelerated ion beams, addresses these shortcomings simultaneously. In a proof-of-principle experiment on a university-scale system, we demonstrate post-acceleration of laser-driven protons from a flat foil at a rate of 0.5 GeV m(-1), already beyond what can be sustained by conventional accelerator technologies, with dynamic beam collimation and energy selection. These results open up new opportunities for the development of extremely compact and cost-effective ion accelerators for both established and innovative applications.
Objective
To describe the trend in surgical volume in urology in Italy during the coronavirus disease 2019 (COVID‐19) outbreak, as a result of the abrupt reorganisation of the Italian national health ...system to augment care provision to symptomatic patients with COVID‐19.
Methods
A total of 33 urological units with physicians affiliated to the AGILE consortium (Italian Group for Advanced Laparo‐Endoscopic Surgery; www.agilegroup.it) were surveyed. Urologists were asked to report the amount of surgical elective procedures week‐by‐week, from the beginning of the emergency to the following month.
Results
The 33 hospitals involved in the study account overall for 22 945 beds and are distributed in 13/20 Italian regions. Before the outbreak, the involved urology units performed overall 1213 procedures/week, half of which were oncological. A month later, the number of surgeries had declined by 78%. Lombardy, the first region with positive COVID‐19 cases, experienced a 94% reduction. The decrease in oncological and non‐oncological surgical activity was 35.9% and 89%, respectively. The trend of the decline showed a delay of roughly 2 weeks for the other regions.
Conclusion
Italy, a country with a high fatality rate from COVID‐19, experienced a sudden decline in surgical activity. This decline was inversely related to the increase in COVID‐19 care, with potential harm particularly in the oncological field. The Italian experience may be helpful for future surgical pre‐planning in other countries not so drastically affected by the disease to date.
Ion acceleration driven by high intensity laser pulses is attracting an impressive and steadily increasing research effort. Experiments over the past 10–15 years have demonstrated, over a wide range ...of laser and target parameters, the generation of multi-MeV proton and ion beams with unique properties, which have stimulated interest in a number of innovative applications. While most of this work has been based on sheath acceleration processes, where space-charge fields are established by relativistic electrons at surfaces of the irradiated target, a number of novel mechanisms has been the focus of recent theoretical and experimental activities. This paper will provide a brief review of the state of the art in the field of laser-driven ion acceleration, with particular attention to recent developments.
We present a technique for simultaneous focusing and energy selection of high-current, mega-electron volt proton beams with the use of radial, transient electric fields (10⁷ to 10¹⁰ volts per meter) ...triggered on the inner walls of a hollow microcylinder by an intense subpicosecond laser pulse. Because of the transient nature of the focusing fields, the proposed method allows selection of a desired range out of the spectrum of the polyenergetic proton beam. This technique addresses current drawbacks of laser-accelerated proton beams, such as their broad spectrum and divergence at the source.
Control of the collective response of plasma particles to intense laser light is intrinsic to relativistic optics, the development of compact laser-driven particle and radiation sources, as well as ...investigations of some laboratory astrophysics phenomena. We recently demonstrated that a relativistic plasma aperture produced in an ultra-thin foil at the focus of intense laser radiation can induce diffraction, enabling polarization-based control of the collective motion of plasma electrons. Here we show that under these conditions the electron dynamics are mapped into the beam of protons accelerated via strong charge-separation-induced electrostatic fields. It is demonstrated experimentally and numerically via 3D particle-in-cell simulations that the degree of ellipticity of the laser polarization strongly influences the spatial-intensity distribution of the beam of multi-MeV protons. The influence on both sheath-accelerated and radiation pressure-accelerated protons is investigated. This approach opens up a potential new route to control laser-driven ion sources.