Objective
Video‐electroencephalography (vEEG) is an important component of epilepsy diagnosis and management. Nevertheless, inpatient vEEG monitoring fails to capture seizures in up to one third of ...patients. We hypothesized that personalized seizure forecasts could be used to optimize the timing of vEEG.
Methods
We used a database of ambulatory vEEG studies to select a cohort with linked electronic seizure diaries of more than 20 reported seizures over at least 8 weeks. The total cohort included 48 participants. Diary seizure times were used to detect individuals' multiday seizure cycles and estimate times of high seizure risk. We compared whether estimated seizure risk was significantly different between conclusive and inconclusive vEEGs, and between vEEG with and without recorded epileptic activity. vEEGs were conducted prior to self‐reported seizures; hence, the study aimed to provide a retrospective proof of concept that cycles of seizure risk were correlated with vEEG outcomes.
Results
Estimated seizure risk was significantly higher for conclusive vEEGs and vEEGs with epileptic activity. Across all cycle strengths, the average time in high risk during vEEG was 29.1% compared with 14% for the conclusive/inconclusive groups and 32% compared to 18% for the epileptic activity/no epileptic activity groups. On average, 62.5% of the cohort showed increased time in high risk during their previous vEEG when epileptic activity was recorded (compared to 28% of the cohort where epileptic activity was not recorded). For conclusive vEEGs, 50% of the cohort had increased time in high risk, compared to 21.5% for inconclusive vEEGs.
Significance
Although retrospective, this study provides a proof of principle that scheduling monitoring times based on personalized seizure risk forecasts can improve the yield of vEEG. Forecasts can be developed at low cost from mobile seizure diaries. A simple scheduling tool to improve diagnostic outcomes may reduce cost and risks associated with delayed or missed diagnosis in epilepsy.
Eleven patients being evaluated with intracranial electroencephalography for medically resistant temporal lobe epilepsy participated in a visual recognition memory task. Interictal epileptiform ...spikes were manually marked and their rate of occurrence compared between baseline and three 2 s periods spanning a 6 s viewing period. During successful, but not unsuccessful, encoding of the images there was a significant reduction in interictal epileptiform spike rate in the amygdala, hippocampus, and temporal cortex. During the earliest encoding period (0-2000 ms after image presentation) in these trials there was a widespread decrease in the power of theta, alpha and beta band local field potential oscillations that coincided with emergent focal gamma frequency activity. Interictal epileptiform spike rate correlated with spectral band power changes and broadband (4-150 Hz) desynchronization, which predicted significant reduction in interictal epileptiform spike rate. Spike-triggered averaging of the field potential power spectrum detected a burst of low frequency synchronization 200 ms before the interictal epileptiform spikes that arose during this period of encoding. We conclude that interictal epileptiform spikes are modulated by the patterns of network oscillatory activity that accompany human memory offering a new mechanistic insight into the interplay of cognitive processing, local field potential dynamics and interictal epileptiform spike generation.
Objective
Ultra long‐term subcutaneous electroencephalography (sqEEG) monitoring is a new modality with great potential for both health and disease, including epileptic seizure detection and ...forecasting. However, little is known about the long‐term quality and consistency of the sqEEG signal, which is the objective of this study.
Methods
The largest multicenter cohort of sqEEG was analyzed, including 14 patients with epilepsy and 12 healthy subjects, implanted with a sqEEG device (24/7 EEG™ SubQ), and recorded from 23 to 230 days (median 42 days), with a median data capture rate of 75% (17.9 hours/day). Median power spectral density plots of each subject were examined for physiological peaks, including at diurnal and nocturnal periods. Long‐term temporal trends in signal impedance and power spectral features were investigated with subject‐specific linear regression models and group‐level linear mixed‐effects models.
Results
sqEEG spectrograms showed an approximate 1/f power distribution. Diurnal peaks in the alpha range (8‐13Hz) and nocturnal peaks in the sigma range (12‐16Hz) were seen in the majority of subjects. Signal impedances remained low, and frequency band powers were highly stable throughout the recording periods.
Significance
The spectral characteristics of minimally invasive, ultra long‐term sqEEG are similar to scalp EEG, whereas the signal is highly stationary. Our findings reinforce the suitability of this system for chronic implantation on diverse clinical applications, from seizure detection and forecasting to brain‐computer interfaces.
Objective
Epilepsy management employs self‐reported seizure diaries, despite evidence of seizure underreporting. Wearable and implantable seizure detection devices are now becoming more widely ...available. There are no clear guidelines about what levels of accuracy are sufficient. This study aimed to simulate clinical use cases and identify the necessary level of accuracy for each.
Methods
Using a realistic seizure simulator (CHOCOLATES), a ground truth was produced, which was then sampled to generate signals from simulated seizure detectors of various capabilities. Five use cases were evaluated: (1) randomized clinical trials (RCTs), (2) medication adjustment in clinic, (3) injury prevention, (4) sudden unexpected death in epilepsy (SUDEP) prevention, and (5) treatment of seizure clusters. We considered sensitivity (0%–100%), false alarm rate (FAR; 0–2/day), and device type (external wearable vs. implant) in each scenario.
Results
The RCT case was efficient for a wide range of wearable parameters, though implantable devices were preferred. Lower accuracy wearables resulted in subtle changes in the distribution of patients enrolled in RCTs, and therefore higher sensitivity and lower FAR values were preferred. In the clinic case, a wide range of sensitivity, FAR, and device type yielded similar results. For injury prevention, SUDEP prevention, and seizure cluster treatment, each scenario required high sensitivity and yet was minimally influenced by FAR.
Significance
The choice of use case is paramount in determining acceptable accuracy levels for a wearable seizure detection device. We offer simulation results for determining and verifying utility for specific use case and specific wearable parameters.
The objective of this study was to describe the sEEG-defined seizure onset zone (SOZ), seizure semiology, presurgical evaluations, surgical intervention and outcome in patients with midline onset ...noninvasive phase I monitoring.
A single center sEEG database was reviewed to identify patients with seizures onset predominantly involving midline electrodes (FZ, CZ, PZ, OZ) on scalp EEG. Data abstracted included clinical factors, seizure semiology graded into lobar segmentation, imaging and electrographic findings, sEEG plan, interventions, and outcome.
Twelve patients were identified (8 males, median age of sEEG 28 years) out of 100 cases of sEEG performed from January 2015-September 2019. “Frontal lobe” seizure semiology was the most common. sEEG-defined SOZ were frontal (5), diffuse (1), multifocal (1), frontal and insular (1), frontal and cingulate (1), insular (1), cingulate (1), and mesial temporal (1). CZ and/or FZ scalp EEG changes were present for all patients with SOZ involving the frontal, cingulate, and insular regions. PZ/OZ scalp involvement was present in one patient with mesial temporal SOZ. Four patients underwent a definitive resective or ablative surgery, and the remaining patients underwent a palliative intervention. Of those with follow-up information available, 8/11 had seizure reduction by ≥ 50%, including 4 with an Engel I outcome. No clinical factors were associated with outcome.
SOZ for midline onset seizures from noninvasive phase I monitoring was most commonly in the frontal, cingulate, and insular regions. A complex cortical network between these regions may explain overlap in semiology and scalp EEG findings. While the number rendered seizure-free was limited, a significant proportion experienced a reasonably favorable outcome justifying use of sEEG to identify surgical options in these patients.
•Midline onset seizures on scalp EEG are rare.•sEEG commonly shows frontal, insular, and/or cingulate onset for these seizures.•A complex seizure network is likely underlying this.
Could direct electrical stimulation of the brain be used to enhance memory? In patients with epilepsy undergoing evaluation for resective surgery, Kucewiczet al. show that stimulation of the lateral ...temporal cortex, but not the hippocampus, parahippocampal neocortex or prefrontal cortex, increases the number of words that patients can remember.
Abstract
Direct electrical stimulation of the human brain can elicit sensory and motor perceptions as well as recall of memories. Stimulating higher order association areas of the lateral temporal cortex in particular was reported to activate visual and auditory memory representations of past experiences (Penfield and Perot, 1963). We hypothesized that this effect could be used to modulate memory processing. Recent attempts at memory enhancement in the human brain have been focused on the hippocampus and other mesial temporal lobe structures, with a few reports of memory improvement in small studies of individual brain regions. Here, we investigated the effect of stimulation in four brain regions known to support declarative memory: hippocampus, parahippocampal neocortex, prefrontal cortex and temporal cortex. Intracranial electrode recordings with stimulation were used to assess verbal memory performance in a group of 22 patients (nine males). We show enhanced performance with electrical stimulation in the lateral temporal cortex (paired t-test, P = 0.0067), but not in the other brain regions tested. This selective enhancement was observed both on the group level, and for two of the four individual subjects stimulated in the temporal cortex. This study shows that electrical stimulation in specific brain areas can enhance verbal memory performance in humans.
awx373media1
5704855796001
One of the most disabling aspects of living with chronic epilepsy is the unpredictability of seizures. Cumulative research in the past decades has advanced our understanding of the dynamics of ...seizure risk. Technological advances have recently made it possible to record pertinent biological signals, including electroencephalogram (EEG), continuously. We aimed to assess whether patient-specific seizure forecasting is possible using remote, minimally invasive ultra-long-term subcutaneous EEG.
We analyzed a two-center cohort of ultra-long-term subcutaneous EEG recordings, including six patients with drug-resistant focal epilepsy monitored for 46-230 days with median 18 h/day of recorded data, totaling >11 000 h of EEG. Total electrographic seizures identified by visual review ranged from 12 to 36 per patient. Three candidate subject-specific long short-term memory network deep learning classifiers were trained offline and pseudoprospectively on preictal (1 h before) and interictal (>1 day from seizures) EEG segments. Performance was assessed relative to a random predictor. Periodicity of the final forecasts was also investigated with autocorrelation.
Depending on each architecture, significant forecasting performance was achieved in three to five of six patients, with overall mean area under the receiver operating characteristic curve of .65-.74. Significant forecasts showed sensitivity ranging from 64% to 80% and time in warning from 10.9% to 44.4%. Overall, the output of the forecasts closely followed patient-specific circadian patterns of seizure occurrence.
This study demonstrates proof-of-principle for the possibility of subject-specific seizure forecasting using a minimally invasive subcutaneous EEG device capable of ultra-long-term at-home recordings. These results are encouraging for the development of a prospective seizure forecasting trial with minimally invasive EEG.
Sentinel epileptiform discharges (SEDs) are epileptiform transients preceding the onset of a focal seizure seen on scalp EEG. Despite their potential localizing value, formal study of SED has been ...limited. The authors report a patient with MRI-negative focal-onset epilepsy whose seizures on scalp and intracranial EEG were always preceded by SED. Although the location and morphology of the SED was invariable, the seizures after the discharge were of two clearly distinct types, each with different semiology and region of spread on intracranial EEG. This suggests that the SED played a role in activating two distinct seizure networks. A right temporal lobectomy with amygdalohippocampectomy was performed. The resection included both the region of the SED as well as the seizure-onset zone of the more common seizure type, achieving seizure freedom at 3 years after surgery. Further research exploring whether the localization of SED is a reliable indicator of the seizure-onset zone could aid surgical planning in patients whose seizures are preceded by SED.
Epilepsy is common among patients with supratentorial brain tumors; approximately 40%-70% of patients with glioma develop brain tumor-related epilepsy (BTRE). Intraoperative localization of the ...epileptogenic zone during surgical tumor resection (real-time data) may improve intervention techniques in patients with lesional epilepsy, including BTRE. Accurate localization of the epileptogenic signals requires electrodes with high-density spatial organization that must be placed on the cortical surface during surgery. The authors investigated a 360° high-density ring-shaped cortical electrode assembly device, called the "circular grid," that allows for simultaneous tumor resection and real-time electrophysiology data recording from the brain surface.
The authors collected data from 99 patients who underwent awake craniotomy from January 2008 to December 2018 (29 patients with the circular grid and 70 patients with strip electrodes), of whom 50 patients were matched-pair analyzed (25 patients with the circular grid and 25 patients with strip electrodes). Multiple variables were then retrospectively assessed to determine if utilization of this device provides more accurate real-time data and improves patient outcomes.
Matched-pair analysis showed higher extent of resection (p = 0.03) and a shorter transient motor recovery period during the hospitalization course (by approximately 6.6 days, p ≤ 0.05) in the circular grid patients. Postoperative versus preoperative Karnofsky Performance Scale (KPS) score difference/drop was greater for the strip electrode patients (p = 0.007). No significant difference in postoperative seizures between the 2 groups was present (p = 0.80).
The circular grid is a safe, feasible tool that grants direct access to the cortical surgical surface for tissue resection while simultaneously monitoring electrical activity. Application of the circular grid to different brain pathologies may improve intraoperative epileptogenic detection accuracy and functional outcomes, while decreasing postoperative complications.