Compact Michelson interferometers are well positioned to replace existing displacement sensors in the readout of seismometers and suspension systems, such as those used in contemporary ...gravitational-wave detectors. Here, we continue our previous investigation of a customised compact displacement sensor built by SmarAct that operates on the principle of deep frequency modulation. The focus of this paper is the linearity of this device and its subsequent impact on sensitivity. We show the three primary sources of nonlinearity that arise in the sensor: residual ellipticity, intrinsic distortion of the Lissajous figure, and distortion caused by exceeding the velocity limit imposed by the demodulation algorithm. We verify the theoretical models through an experimental demonstration, where we show the detrimental impact that these nonlinear effects have on device sensitivity. Finally, we simulate the effect that these nonlinearities are likely to have if implemented in the readout of the Advanced LIGO suspensions and show that the noise from nonlinearities should not dominate across the key sub-10 Hz frequency band.
The discovery of gravitational waves opened a new way to look at the Universe and offered new opportunities to shed light on the still unknown aspects of physical sciences. The work presented in this ...thesis wants to give a contribution to the development of this new type of research: the author chose to focus on the improvement of the instruments able to detect the gravitational waves. This field is important to make the detectors more sensitive, in order to see more gravitational wave sources and help to complete the mosaic of the astrophysical science. In particular, the detectors currently in use are interferometers, which are especially blind in a range of frequency below 30 Hz: this affects the chance to detect sources emitting in this frequency band. This lack of sensitivity is mainly due to seismic motion, and the work presented in this thesis focussed on new techniques to lower the noise sources and allow the instruments to be sensitive below 30 Hz. During the studies, the development and test of devices capable of potentially reducing the seismic motion have been performed, such as optical levers for tilt motion reduction and laser stabilization for low frequency readout; a new concept of the seismic system on one of the interferometers (LIGO) has also been proposed. The optical levers can in principle reduce tilt motion below 1 Hz; the use of capacitive position sensors in a new software configuration for LIGO can help to suppress ground motion by a factor of 3 in order of magnitude below 0.1 Hz. A competitive frequency stabilization to 3.6 × 103 Hz/√ Hz at 1 Hz for readout at low frequency is possible with a compact and easy to handle setup. These results are promising to provide suppression of the seismic motion in the bandwidth of interest and show that it is possible for a ground-based instrument to be seismically more stable and capable of detecting gravitational waves where it is now forbidden.
Compact Michelson interferometers are well positioned to replace existing displacement sensors in the readout of seismometers and suspension systems, such as those used in contemporary ...gravitational-wave detectors. Here, we continue our previous investigation of a customised compact displacement sensor built by SmarAct, which operated on the principle of deep frequency modulation. The focus of this paper is on the linearity of this device. We show the three primary sources of nonlinearity that arise in the sensor -- residual ellipticity, intrinsic distortion of the Lissajous figure, and distortion caused by exceeding the velocity limit imposed by the demodulation algorithm. We verify the theoretical models through an experimental demonstration designed to maximise the nonlinear noise to dominate regions of the readout's power spectrum. We finally simulate the effect that these nonlinearities are likely to have if implemented in the readout of the Advanced LIGO suspensions and show that the noise nonlinearities should not dominate across the key sub-\SI{10}{\Hz} frequency band.
We present the design, control system, and noise analysis of a 6-axis seismometer comprising a mass suspended by a single fused silica fibre. We utilise custom-made, compact Michelson interferometers ...for the readout of the mass motion relative to the table and successfully overcome the sensitivity of existing commercial seismometers by over an order of magnitude in the angular degrees of freedom. We develop the sensor for gravitational-wave observatories, such as LIGO, Virgo, and KAGRA, to help them observe intermediate-mass black holes, increase their duty cycle, and improve localisation of sources. Our control system and its achieved sensitivity makes the sensor suitable for other fundamental physics experiments, such as tests of semiclassical gravity, searches for bosonic dark matter, and studies of the Casimir force.
We demonstrate the control scheme of an active platform with a six degree of freedom (6D) seismometer. The inertial sensor simultaneously measures translational and tilt degrees of freedom of the ...platform and does not require any additional sensors for the stabilisation. We show that a feedforward cancellation scheme can efficiently decouple tilt-to-horizontal coupling of the seismometer in the digital control scheme. We stabilise the platform in the frequency band from 250 mHz up to 10 Hz in the horizontal degrees of freedom and achieve a suppression factor of 100 around 1 Hz. Further suppression of ground vibrations was limited by the non-linear response of the piezo actuators of the platform and by its limited range (5 {\mu}m). In this paper we discuss the 6D seismometer, its control scheme, and the limitations of the test bed.