This article reports world averages of measurements of
b
-hadron,
c
-hadron, and
τ
-lepton properties obtained by the Heavy Flavor Averaging Group using results available through summer 2016. For the ...averaging, common input parameters used in the various analyses are adjusted (rescaled) to common values, and known correlations are taken into account. The averages include branching fractions, lifetimes, neutral meson mixing parameters,
C
P
violation parameters, parameters of semileptonic decays, and Cabbibo–Kobayashi–Maskawa matrix elements.
The DMAPS upgrade of the Belle II vertex detector Babeluk, M.; Barbero, M.; Baudot, J. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
07/2024, Letnik:
1064
Journal Article
Recenzirano
The Belle II experiment at KEK in Japan considers an upgrade for the vertex detector system in line with the accelerator upgrade for higher luminosity at long shutdown 2 planned for 2028.
One ...proposal for the upgrade of the vertex detector called VTX aims to improve background robustness and reduce occupancy using small and fast pixels. VTX accommodates the OBELIX depleted monolithic active CMOS pixel sensor (DMAPS) on all five proposed layers. OBELIX is specifically developed for the VTX application and based on the TJ-Monopix2 chip initially developed to meet the requirements of the outer layers of the ATLAS inner tracker (ITk).
This paper will review recent tests of the TJ-Monopix2 chip as well as various design aspects of the OBELIX-1 chip currently under development.
The OBELIX chip for the Belle II VTX upgrade Babeluk, M.; Auguste, D.; Barbero, M. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
October 2024, Letnik:
1067
Journal Article
Recenzirano
The OBELIX depleted monolithic active CMOS pixel sensor (DMAPS) is currently developed for the upgrade of the vertex detector of the Belle II experiment located at Tsukuba/Japan. The pixel matrix of ...OBELIX is inherited from the TJ-Monopix2 chip, but the periphery includes additional features to improve performance and allow the integration into a larger detector system. The new features include a trigger unit to process trigger signals, a precision timing module and a possibility to transmit low granularity hit information with low latency to contribute to the Belle II trigger. Additionally, low dropout voltage regulators and an ADC to monitor power consumption and substrate temperature is developed. This paper will focus on the trigger contribution capabilities of the OBELIX chip.
Depleted Monolithic Active Pixel Sensors (DMAPS) are monolithic pixel detectors with high-resistivity substrates designed for use in high-rate and high-radiation environments. They are produced in ...commercial CMOS processes, resulting in relatively low production costs and short turnaround times, and offer a low material budget. LF-Monopix1 and TJ-Monopix1 are large DMAPS prototypes produced in 150 nm LFoundry and 180 nm TowerJazz technology, respectively, that follow two different design concepts regarding the charge collection electrode. Prototypes of both development lines have been extensively tested and characterized over the last years. The second-generation Monopix prototypes, Monopix2, were recently produced. They were designed to address the shortcomings of their predecessors, in particular related to radiation hardness and cross talk, and further improve upon their performance. The latest measurements with LF-Monopix1 and TJ-Monopix1 concerning hit efficiency, depletion, and radiation hardness as well as the initial test results of the new Monopix2 prototypes are presented.
DMAPS Monopix developments in large and small electrode designs Bespin, C.; Barbero, M.; Barrillon, P. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
10/2020, Letnik:
978
Journal Article
Recenzirano
Odprti dostop
LF-Monopix1 and TJ-Monopix1 are depleted monolithic active pixel sensors (DMAPS) in 150nm LFoundry and 180nm TowerJazz CMOS technologies respectively. They are designed for usage in high-rate and ...high-radiation environments such as the ATLAS Inner Tracker at the High-Luminosity Large Hadron Collider (HL-LHC). Both chips are read out using a column-drain readout architecture. LF-Monopix1 follows a design with large charge collection electrode where readout electronics are placed inside. Generally, this offers a homogeneous electrical field in the sensor and short drift distances. TJ-Monopix1 employs a small charge collection electrode with readout electronics separated from the electrode and an additional n-type implant to achieve full depletion of the sensitive volume. This approach offers a low sensor capacitance and therefore low noise and is typically implemented with small pixel size. Both detectors have been characterized before and after irradiation using lab tests and particle beams.
This paper reports world averages of measurements of b-hadron, c-hadron, and τ-lepton properties obtained by the Heavy Flavour Averaging Group using results available through September 2018. In rare ...cases, significant results obtained several months later are also used. For the averaging, common input parameters used in the various analyses are adjusted (rescaled) to common values, and known correlations are taken into account. The averages include branching fractions, lifetimes, neutral meson mixing parameters, CP violation parameters, parameters of semileptonic decays, and Cabibbo–Kobayashi–Maskawa matrix elements.
Although it has been shown that the production of functional chimeric antigen receptor T cells is feasible in patients with B-cell malignancies, it is currently unclear whether sufficient amounts of ...functional autologous CAR T cells can be generated from patients with autoimmune diseases. Intrinsic T-cell abnormalities and T-cell-targeted immune suppression in patients with autoimmunity may hamper the retrieval of sufficient T cells and their transduction and expansion into CAR T cells. Patients with active systemic lupus erythematosus (SLE) underwent leukapheresis after tapering glucocorticoids and stopping T-cell-suppressive drugs. This material was used as source for manufacturing anti-CD19 CAR T-cell products (CAR) in clinical scale. Cells were transduced with a lentiviral anti-CD19 CAR vector and expanded under good manufacturing practice (GMP) conditions using a closed, semi-automatic system. Functionality of these CAR T cells derived from autoimmune patient cells was tested in vitro. Six SLE patients were analyzed. Leukapheresis could be successfully performed in all patients yielding sufficient T-cell numbers for clinical scale CAR T-cell production. In addition, CAR T cells showed high expansion rates and viability, leading to CAR T cells in sufficient doses and quality for clinical use. CAR T cells from all patients showed specific cytotoxicity against CD19+ cell lines in vitro. GMP grade generation of CD19 CAR T-cell products suitable for clinical use is feasible in patients with autoimmune disease.
The Belle II Silicon Vertex Detector Friedl, M.; Ackermann, K.; Aihara, H. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
12/2013, Letnik:
732
Journal Article
Recenzirano
Odprti dostop
The KEKB machine and the Belle experiment in Tsukuba (Japan) are now undergoing an upgrade, leading to an ultimate luminosity of 8×1035cm−2s−1 in order to measure rare decays in the B system with ...high statistics.
The previous vertex detector cannot cope with this 40-fold increase of luminosity and thus needs to be replaced. Belle II will be equipped with a two-layer Pixel Detector surrounding the beam pipe, and four layers of double-sided silicon strip sensors at higher radii than the old detector. The Silicon Vertex Detector (SVD) will have a total sensitive area of 1.13m2 and 223,744 channels—twice as many as its predecessor.
All silicon sensors will be made from 150mm wafers in order to maximize their size and thus to reduce the relative contribution of the support structure. The forward part has slanted sensors of trapezoidal shape to improve the measurement precision and to minimize the amount of material as seen by particles from the vertex. Fast-shaping front-end amplifiers will be used in conjunction with an online hit time reconstruction algorithm in order to reduce the occupancy to the level of a few percent at most. A novel “Origami” chip-on-sensor scheme is used to minimize both the distance between strips and amplifier (thus reducing the electronic noise) as well as the overall material budget.
This report gives an overview on the status of the Belle II SVD and its components, including sensors, front-end detector ladders, mechanics, cooling and the readout electronics.