Toxic shock syndrome toxin 1 (TSST-1) is a Staphylococcus aureus superantigen that has been implicated in both menstrual and nonmenstrual toxic shock syndrome (TSS). Despite the important role of ...TSST-1 in severe human disease, a comprehensive understanding of staphylococcal regulatory factors that control TSST-1 expression remains incomplete. The S. aureus exotoxin expression (Sae) operon contains a well-characterized two-component system that regulates a number of important exotoxins in S. aureus, although regulation of TSST-1 by the Sae system has not been investigated. We generated a defined deletion mutant of the Sae histidine kinase sensor (saeS) in the prototypic menstrual TSS strain S. aureus MN8. Mutation of saeS resulted in a complete loss of TSST-1 expression. Using both luciferase reporter experiments and quantitative real-time PCR, we demonstrate that the Sae system is an important transcriptional activator of TSST-1 expression. Recombinant SaeR was able to bind directly to the tst promoter to a region containing two SaeR consensus binding sites. Although the stand-alone SarA transcriptional regulator has been shown to be both a positive and a negative regulator of TSST-1, deletion of sarA in S. aureus MN8 resulted in a dramatic overexpression of TSST-1. As expected, mutation of agr also reduced TSST-1 expression, but this phenotype appeared to be independent of Sae. A double mutation of saeS and sarA resulted in the loss of TSST-1 expression. This work indicates that the Sae system is a dominant and direct transcriptional activator that is required for expression of TSST-1.
The TSST-1 superantigen is an exotoxin, produced by some strains of S. aureus, that has a clear role in both menstrual and nonmenstrual TSS. Although the well-characterized agr quorum sensing system is a known positive regulator of TSST-1, the molecular mechanisms that directly control TSST-1 expression are only partially understood. Our studies demonstrate that the Sae two-component regulatory system is a positive transcriptional regulator that binds directly to the TSST-1 promoter, and furthermore, our data suggest that Sae is required for expression of TSST-1. This work highlights how major regulatory circuits can converge to fine-tune exotoxin expression and suggests that the Sae regulatory system may be an important target for antivirulence strategies.
Objective We report our experience of functional imaging with 11C-methionine positron emission tomography–computed tomography (PET–CT) co-registered with 3D gradient echo (spoiled gradient recalled ...(SPGR)) magnetic resonance imaging (MRI) in the investigation of ACTH-dependent Cushing's syndrome. Design Twenty patients with i) de novo Cushing's disease (CD, n=10), ii) residual or recurrent hypercortisolism following first pituitary surgery (±radiotherapy; n=8) or iii) ectopic Cushing's syndrome (n=2) were referred to our centre for functional imaging studies between 2010 and 2015. Six of the patients with de novo CD and five of those with persistent/relapsed disease had a suspected abnormality on conventional MRI. Methods All patients underwent 11C-methionine PET–CT. For pituitary imaging, co-registration of PET–CT images with contemporaneous SPGR MRI (1 mm slice thickness) was performed, followed by detailed mapping of 11C-methionine uptake across the sella in three planes (coronal, sagittal and axial). This allowed us to determine whether suspected adenomas seen on structural imaging exhibited focal tracer uptake on functional imaging. Results In seven of ten patients with de novo CD, asymmetric 11C-methionine uptake was observed within the sella, which co-localized with the suspected site of a corticotroph microadenoma visualised on SPGR MRI (and which was subsequently confirmed histologically following successful transsphenoidal surgery (TSS)). Focal 11C-methionine uptake that correlated with a suspected abnormality on pituitary MRI was seen in five of eight patients with residual or recurrent Cushing's syndrome following first TSS (and pituitary radiotherapy in two cases). Two patients elected to undergo repeat TSS with histology confirming a corticotroph tumour in each case. In two patients with the ectopic ACTH syndrome, 11C-methionine was concentrated in sites of distant metastases, with minimal uptake in the sellar region. Conclusions 11C-methionine PET–CT can aid the detection of ACTH-secreting tumours in Cushing's syndrome and facilitate targeted therapy.
Background
Pituitary adenomas (PA) affect ~ 1:1200 of the population and can cause a wide range of symptoms due to hormone over-secretion, loss of normal pituitary gland function and/or compression ...of visual pathways, resulting in significantly impaired quality of life. Surgery is potentially curative if the location of the adenoma can be determined. However, standard structural (anatomical) imaging, in the form of MRI, is unable to locate all tumors, especially microadenomas (< 1 cm diameter). In such cases, functional imaging
11
C-methionine PET/CT (Met-PET) can facilitate tumor detection, although may be inconclusive when the adenoma is less metabolically active. We, therefore, explored whether subtraction imaging, comparing findings between two Met-PET scans with medical therapy-induced suppression of tumor activity in the intervening period, could increase confidence in adenoma localization. In addition, we assessed whether normalization to a reference region improved consistency of pituitary gland signal in healthy volunteers who underwent two Met-PET scans without medical suppression.
Results
We found that the mean percentage differences in maximum pituitary uptake between two Met-PET scans in healthy volunteers were 2.4% for (SUVr) cerebellum, 8.8% for SUVr pons, 5.2% for SUVr gray matter and 23.1% for the SUVbw no region. Laterality, as measured by contrast–noise ratio (CNR), indicated the correct location of the adenoma in all three image types with mean CNR values of 6.2, 8.1 and 11.1 for SUVbw, SUVbwSub and SUVrSub cerebellum, respectively. Subtraction imaging improved CNR in 60% and 100% of patients when using images generated from SUVbw no region and SUVr cerebellum scans compared to standard clinical SUVbw imaging.
Conclusions
Met-PET scans should be normalized to the cerebellum to minimize the effects of physiological variation in pituitary gland uptake of 11C-methionine, especially when comparing serial imaging. Subtraction imaging following endocrine suppression of tumor function improved lateralization of PA when compared with single time point clinical Met-PET but, importantly, only if the images were normalized to the cerebellum prior to subtraction.
Background
Image optimization is a key step in clinical nuclear medicine, and phantoms play an essential role in this process. However, most phantoms do not accurately reflect the complexity of human ...anatomy, and this presents a particular challenge when imaging endocrine glands to detect small (often subcentimeter) tumors. To address this, we developed a novel phantom for optimization of positron emission tomography (PET) imaging of the human pituitary gland. Using radioactive 3D printing, phantoms were created which mimicked the distribution of
11
C-methionine in normal pituitary tissue and in a small tumor embedded in the gland (i.e., with no inactive boundary, thereby reproducing the in vivo situation). In addition, an anatomical phantom, replicating key surrounding structures based on computed tomography (CT) images from an actual patient, was created using material extrusion 3D printing with specialized filaments that approximated the attenuation properties of bone and soft tissue.
Results
The phantom enabled us to replicate pituitary glands harboring tumors of varying sizes (2, 4 and 6 mm diameters) and differing radioactive concentrations (2 ×, 5 × and 8 × the normal gland). The anatomical phantom successfully approximated the attenuation properties of surrounding bone and soft tissue. Two iterative reconstruction algorithms ordered subset expectation maximization (OSEM); Bayesian penalized likelihood (BPL) with a range of reconstruction parameters (e.g., 3, 5, 7 and 9 OSEM iterations with 24 subsets; BPL regularization parameter (
β
) from 50 to 1000) were tested. Images were analyzed quantitatively and qualitatively by eight expert readers. Quantitatively, signal was the highest using BPL with
β
= 50; noise was the lowest using BPL with
β
= 1000; contrast was the highest using BPL with
β
= 100. The qualitative review found that accuracy and confidence were the highest when using BPL with
β
= 400.
Conclusions
The development of a bespoke phantom has allowed the identification of optimal parameters for molecular pituitary imaging: BPL reconstruction with TOF, PSF correction and a
β
value of 400; in addition, for small (< 4 mm) tumors with low contrast (2:1 or 5:1), sensitivity may be improved using a
β
value of 100. Together, these findings should increase tumor detection and confidence in reporting scans.
Background
Pituitary adenomas can give rise to a variety of clinical disorders and surgery is often the primary treatment option. However, preoperative magnetic resonance imaging (MRI) does not ...always reliably identify the site of an adenoma. In this setting molecular (functional) imaging (e.g.
11
C-methionine PET/CT) may help with tumor localisation, although interpretation of these 2D images can be challenging. 3D printing of anatomical models for other indications has been shown to aid surgical planning and improve patient understanding of the planned procedure. Here, we explore the potential utility of four types of 3D printing using PET/CT and co-registered MRI for visualising pituitary adenomas.
Methods
A 3D patient-specific model based on a challenging clinical case was created by segmenting the pituitary gland, pituitary adenoma, carotid arteries and bone using contemporary PET/CT and MR images. The 3D anatomical models were printed using VP, MEX, MJ and PBF 3D printing methods. Different anatomical structures were printed in color with the exception of the PBF anatomical model where a single color was used. The anatomical models were compared against the computer model to assess printing accuracy. Three groups of clinicians (endocrinologists, neurosurgeons and ENT surgeons) assessed the anatomical models for their potential clinical utility.
Results
All of the printing techniques produced anatomical models which were spatially accurate, with the commercial printing techniques (MJ and PBF) and the consumer printing techniques (VP and MEX) demonstrating comparable findings (all techniques had mean spatial differences from the computer model of < 0.6 mm). The MJ, VP and MEX printing techniques yielded multicolored anatomical models, which the clinicians unanimously agreed would be preferable to use when talking to a patient; in contrast, 50%, 40% and 0% of endocrinologists, neurosurgeons and ENT surgeons respectively would consider using the PBF model.
Conclusion
3D anatomical models of pituitary tumors were successfully created from PET/CT and MRI using four different 3D printing techniques. However, the expert reviewers unanimously preferred the multicolor prints. Importantly, the consumer printers performed comparably to the commercial MJ printing technique, opening the possibility that these methods can be adopted into routine clinical practice with only a modest investment.
Purpose
Phantoms are routinely used in molecular imaging to assess scanner performance. However, traditional phantoms with fillable shapes do not replicate human anatomy. 3D-printed phantoms have ...overcome this by creating phantoms which replicate human anatomy which can be filled with radioactive material. The problem with these is that small objects suffer to a greater extent than larger objects from the effects of inactive walls, and therefore, phantoms without these are desirable. The purpose of this study was to explore the feasibility of creating resin-based 3D-printed phantoms using
18
F.
Methods
Radioactive resin was created using an emulsion of printer resin and
18
F-FDG. A series of test objects were printed including twenty identical cylinders, ten spheres with increasing diameters (2 to 20 mm), and a double helix. Radioactive concentration uniformity, printing accuracy and the amount of leaching were assessed.
Results
Creating radioactive resin was simple and effective. The radioactive concentration was uniform among identical objects; the CoV of the signal was 0.7% using a gamma counter. The printed cylinders and spheres were found to be within 4% of the model dimensions. A double helix was successfully printed as a test for the printer and appeared as expected on the PET scanner. The amount of radioactivity leached into the water was measurable (0.72%) but not visible above background on the imaging.
Conclusions
Creating an
18
F radioactive resin emulsion is a simple and effective way to create accurate and complex phantoms without inactive walls. This technique could be used to print clinically realistic phantoms. However, they are single use and cannot be made hollow without an exit hole. Also, there is a small amount of leaching of the radioactivity to take into consideration.
Objectives: he aim of this study was to retrospectively review the use of radium-223 within an unselected semi-rural population and to determine if there is a survival advantage in completing all 6 ...cycles of treatment. The electronic patients records of all patients treated with at least 1 cycle of radium-223 with a minimum 6 months follow up since its launch in June 2014 were reviewed. The overall survival was assessed and the time of death compared in those patients who had received all 6 cycles of 55kBq/kg with those who had received less than 6 cycles. A total of 528 cycles was administered to 114 men with castrate resistant prostate cancer. The average age of the patients treated was 73 the youngest was 49 and the oldest 87. A total of 46 (40%) of patients have died. There were 23 deaths in the 68 patients who received all 6 cycles of radium-223 (34%) and 23 deaths in the 46 patients who received less than 6 cycles of treatment (50%). Those that died having received less than 6 cycles had a mean 2.6 cycles of treatment before it was stopped. The median overall survival was 16 months. The median overall survival of those who received all 6 treatments has not been reached but will be at least 33 months. The mean overall survival of those who died receiving less than 6 cycles was 4.1 months compared to 12.5 months for those who died after receiving all 6 cycles of treatment (p=0.01 student’s unpaired T test). There was no difference in the mean age for the two groups (73 if less than 6 cycles given and 75 if all 6 cycles given) Conclusions: It is clearly possible to operate a community based radium-223 service but if possible all 6 cycles of treatment should be given as this has a significant effect on overall survival of men with bone metastases from castrate resistant prostate cancer.