We performed serial intravascular ultrasound analysis in patients who underwent balloon dilatation for in-stent restenosis. Early lumen loss was detected by intravascular ultrasound and was ...associated with minimal changes at the edges and at the external elastic membrane. These results on intravascular ultrasound suggest compression and decompression as the main mechanisms for early lumen loss after dilatation of in-stent restenotic lesions.
Conventional sirolimus-eluting stent (SES) implantation typically follows balloon predilation. The impact of direct SES implantation on in-stent neointimal hyperplasia and the adjacent reference ...segments has not been evaluated. The aim of this study was to analyze direct and conventional SES implantation techniques by angiography and serial intravascular ultrasound. Fifty-three patients with single de novo coronary lesions underwent successful conventional (n = 26) and direct (n = 27) SES implantation. At 6-month follow-up, similar in-stent late luminal loss and decreased neointimal hyperplasia volume were seen in the 2 groups, preserving the luminal dimensions at the edges of the stents.
Percutaneous mitral valve commissurotomy offers a safe alternative to treat mitral valve stenosis in a select group of patients, and has produced good results. Recently, a new metallic commissurotomy ...device was made available for clinical use. A rare, life-threatening complication associated with this new technique is described.
OBJETIVO: Estabelecer a correlação da cintilografia de perfusão do miocárdio (CPM) com Tecnécio 99m-MIBI (MIBI) e injeção de adenosina, empregando a angiografia coronária quantitativa (ACQ) e o ...ultra-som intracoronário (UIC) como comparação. MÉTODOS: Estudo de 70 pacientes com doença arterial coronária (DAC), encaminhados à CPM com MIBI e adenosina. As manifestações clínicas, do eletrocardiograma (ECG) e os resultados das imagens foram correlacionadas às variáveis da análise visual e quantitativa da angiografia, bem como ao UIC. RESULTADOS: A média de idades foi de 60,6 anos, com 39 pacientes do sexo masculino. A angiografia coronária evidenciou estenose do diâmetro da luz (E%) de 49,94% em 105 artérias, com reavaliação à ACQ em 83 artérias (79%) e média de 44,20%, p<0,05. Infradesnível de ST durante adenosina associou-se a maiores graus de E% (55,0% vs 47,8%), p<0,05). A isquemia cintilográfica correlacionou-se a maior área porcentual de obstrução da luz pelo UIC (AO%). Os achados clínicos, do ECG e das imagens foram considerados em conjunto e expressos como respostas globais isquêmicas versus não-isquêmicas . A isquemia associou-se a menores valores do diâmetro mínimo da luz (DML) e da área mínima da luz (AML), obtidos à ACQ e ao UIC. CONCLUSÃO: A cintilografia do miocárdio com 99mTc-MIBI e adenosina correlaciona-se à AO% ao UIC, considerando-se as imagens de perfusão. Na avaliação dos resultados globais da prova observa-se associação com os diâmetros e as áreas da luz nos locais de obstrução, obtidos à ACQ e ao UIC.
OBJETIVO: Estabelecer a correlação da cintilografia de perfusão do miocárdio (CPM) com Tecnécio 99m-MIBI (MIBI) e injeção de adenosina, empregando a angiografia coronária quantitativa (ACQ) e o ...ultra-som intracoronário (UIC) como comparação. MÉTODOS: Estudo de 70 pacientes com doença arterial coronária (DAC), encaminhados à CPM com MIBI e adenosina. As manifestações clínicas, do eletrocardiograma (ECG) e os resultados das imagens foram correlacionadas às variáveis da análise visual e quantitativa da angiografia, bem como ao UIC. RESULTADOS: A média de idades foi de 60,6 anos, com 39 pacientes do sexo masculino. A angiografia coronária evidenciou estenose do diâmetro da luz (E%) de 49,94% em 105 artérias, com reavaliação à ACQ em 83 artérias (79%) e média de 44,20%, p<0,05. Infradesnível de ST durante adenosina associou-se a maiores graus de E% (55,0% vs 47,8%), p<0,05). A isquemia cintilográfica correlacionou-se a maior área porcentual de obstrução da luz pelo UIC (AO%). Os achados clínicos, do ECG e das imagens foram considerados em conjunto e expressos como respostas globais isquêmicas versus não-isquêmicas . A isquemia associou-se a menores valores do diâmetro mínimo da luz (DML) e da área mínima da luz (AML), obtidos à ACQ e ao UIC. CONCLUSÃO: A cintilografia do miocárdio com 99mTc-MIBI e adenosina correlaciona-se à AO% ao UIC, considerando-se as imagens de perfusão. Na avaliação dos resultados globais da prova observa-se associação com os diâmetros e as áreas da luz nos locais de obstrução, obtidos à ACQ e ao UIC.OBJECTIVE: To correlate myocardial perfusion scintigraphy (MPS) with Tc-99m-MIBI and adenosine infusion using quantitative coronary angiography (QCA) and intravascular ultrasound (IVUS). METHODS: Seventy patients with coronary artery disease (CAD) referred for myocardial perfusion scintigraphy (MPS) with MIBI and adenosine were studied. Clinical, electrocardiographic (ECG), and scintigraphic findings were correlated with variables of visual and quantitative angiographic analysis, as well as to those of IVUS. RESULTS: The mean age of patients was 60.6 years, and 39 were male. Coronary angiography showed percentage of diameter stenosis (% DS) of 49.94% in 105 arteries, 83 of which were re-evaluated by QCA (79%), mean of 44.20%, p<0.05. ST-segment depression during adenosine infusion was associated with higher degrees of % DS (55.0% vs. 47.8%), p<0.05). Scintigraphic ischemia was correlated with greater cross-sectional area of lumen obstruction by IVUS (% CSA). Clinical, ECG, and IVUS findings were considered together and expressed as global ischemic versus non-ischemic responses. Ischemia was associated with lower values of minimal lumen diameter (MLD) and minimal lumen area (MLA) determined by QCA and IVUS. CONCLUSION: Tc-99m-MIBI and adenosine myocardial SPECT is correlated with % CSA on IVUS, perfusion images considered. Global results assessment showed association between lumen diameter and area at obstructed sites as determined by QCA and IVUS.
To correlate myocardial perfusion scintigraphy (MPS) with Tc-99m-MIBI and adenosine infusion using quantitative coronary angiography (QCA) and intravascular ultrasound (IVUS).
Seventy patients with ...coronary artery disease (CAD) referred for myocardial perfusion scintigraphy (MPS) with MIBI and adenosine were studied. Clinical, electrocardiographic (ECG), and scintigraphic findings were correlated with variables of visual and quantitative angiographic analysis, as well as to those of IVUS.
The mean age of patients was 60.6 years, and 39 were male. Coronary angiography showed percentage of diameter stenosis (% DS) of 49.94% in 105 arteries, 83 of which were re-evaluated by QCA (79%), mean of 44.20%, p<0.05. ST-segment depression during adenosine infusion was associated with higher degrees of % DS (55.0% vs. 47.8%), p<0.05). Scintigraphic ischemia was correlated with greater cross-sectional area of lumen obstruction by IVUS (% CSA). Clinical, ECG, and IVUS findings were considered together and expressed as global ischemic versus non-ischemic responses. Ischemia was associated with lower values of minimal lumen diameter (MLD) and minimal lumen area (MLA) determined by QCA and IVUS.
Tc-99m-MIBI and adenosine myocardial SPECT is correlated with % CSA on IVUS, perfusion images considered. Global results assessment showed association between lumen diameter and area at obstructed sites as determined by QCA and IVUS.