Coating thermal noise is one of the dominant noise sources in current gravitational wave detectors and ultimately limits their ability to observe weaker or more distant astronomical sources. This ...Letter presents investigations of TiO_{2} mixed with SiO_{2} (TiO_{2}:SiO_{2}) as a coating material. We find that, after heat treatment for 100 h at 850 °C, thermal noise of a highly reflective coating comprising of TiO_{2}:SiO_{2} and SiO_{2} reduces to 76% of the current levels in the Advanced LIGO and Advanced Virgo detectors-with potential for reaching 45%, if we assume the mechanical loss of state-of-the-art SiO_{2} layers. Furthermore, those coatings show low optical absorption of <1 ppm and optical scattering of ≲5 ppm. Notably, we still observe excellent optical and thermal noise performance following crystallization in the coatings. These results show the potential to meet the parameters required for the next upgrades of the Advanced LIGO and Advanced Virgo detectors.
TiO 2 doped GeO 2 thin films with excellent optical properties and exceptionally low mechanical loss for a ternary amorphous oxide are used to demonstrate interference coatings with low thermal noise ...for the test masses of gravitational wave interferometers.
The most sensitive measurements of time and space are made with resonant optical cavities, and these measurements are limited by coating thermal noise. The mechanical and optical performance ...requirements placed on coating materials, especially for interferometric gravitational wave detectors, have proven extremely difficult to meet despite a lengthy search. In this paper we propose a new approach to high performance coatings; the use of multiple materials at different depths in the coating. To support this we generalize previous work on thermal noise in two-material coatings to an arbitrary multi-material stack, and develop a means of estimating absorption in these multi- material coatings. This new approach will allow for a broadening of the search for high performance coating materials.
Advanced gravitational wave interferometric detectors will operate at their design sensitivity with nearly 1MW of laser power stored in the arm cavities. Such large power may lead to the uncontrolled ...growth of acoustic modes in the test masses due to the transfer of optical energy to the mechanical modes of the arm cavity mirrors. These parametric instabilities have the potential of significantly compromising the detector performance and control. Here we present the design of "acoustic mode dampers" that use the piezoelectric effect to reduce the coupling of optical to mechanical energy. Experimental measurements carried on an Advanced LIGO-like test mass shown a 10-fold reduction in the amplitude of several mechanical modes, thus suggesting that this technique can greatly mitigate the impact of parametric instabilities in advanced detectors.
Interferometric gravitational wave detectors operate with high optical power in their arms in order to achieve high shot-noise limited strain sensitivity. A significant limitation to increasing the ...optical power is the phenomenon of three-mode parametric instabilities, in which the laser field in the arm cavities is scattered into higher order optical modes by acoustic modes of the cavity mirrors. The optical modes can further drive the acoustic modes via radiation pressure, potentially producing an exponential buildup. One proposed technique to stabilize parametric instability is active damping of acoustic modes. We report here the first demonstration of damping a parametrically unstable mode using active feedback forces on the cavity mirror. A 15,538 Hz mode that grew exponentially with a time constant of 182 sec was damped using electro-static actuation, with a resulting decay time constant of 23 sec. An average control force of 0.03 nNrms was required to maintain the acoustic mode at its minimum amplitude.
Triply resonant three mode interactions in long optical cavities have been shown to lead to enhanced scattering of carrier light by the ultrasonic acoustic modes of the test mass mirrors. At high ...optical power, this can lead to parametric instability (parametric gain R > 1) for a few acoustic modes with strong spectral and spatial overlap. Numerous ?~10^3 acoustic modes of the test masses are predicted to have R > 10^2. Experimental studies have shown that such modes also strongly scatter the carrier light, enabling very sensitive readout of the acoustic modes. The 3-mode scattering from the thermal fluctuation of large population of ultrasonic modes would causes random changes in occupation number of the carrier light and cavity transverse optical modes. Because the thermal fluctuation time scale (set by the acoustic mode relaxation times) is typically a few seconds, the noise spectrum from thermally induced photon number fluctuations is strongly peaked at low frequency. The noise level depends on the acoustic mode structure and acoustic losses of the test masses, the transverse optical mode spectrum of the optical cavities and on the test mass temperature. We theoretically investigate the possible effect of this noise and show that in advanced detectors under construction three mode interaction noise is below the standard quantum limit, but could set limits on future low frequency detectors that aim to exceed the free mass standard quantum limit.