The 7σ discrepancy between the proton rms charge radius from muonic hydrogen and the CODATA-2010 value from hydrogen spectroscopy and electron-scattering has caused considerable discussions. Here, we ...review the theory of the 2S–2P Lamb shift and 2S hyperfine splitting in muonic hydrogen combining the published contributions and theoretical approaches. The prediction of these quantities is necessary for the determination of both proton charge and Zemach radii from the two 2S–2P transition frequencies measured in muonic hydrogen; see Pohl et al. (2010) 9 and Antognini et al. (2013) 71.
► We update the theory of Lamb shift and hyperfine splitting in muonic hydrogen. ► We found no large error or missing contribution larger than 0.001 meV. ► We critically discuss the proton-structure-dependent contributions. ► The proton radius puzzle still remains.
Laser spectroscopy of muonic deuterium Pohl, Randolf; Nez, François; Fernandes, Luis M. P. ...
Science (American Association for the Advancement of Science),
08/2016, Letnik:
353, Številka:
6300
Journal Article
Recenzirano
Odprti dostop
The deuteron is the simplest compound nucleus, composed of one proton and one neutron. Deuteron properties such as the root-mean-square charge radius rd and the polarizability serve as important ...benchmarks for understanding the nuclear forces and structure. Muonic deuterium μd is the exotic atom formed by a deuteron and a negative muon μ⁻. We measured three 2S-2P transitions in μd and obtain rd = 2.12562(78) fm, which is 2.7 times more accurate but 7.5σ smaller than the CODATA-2010 value rd = 2.1424(21) fm. The μd value is also 3.5σ smaller than the rd value from electronic deuterium spectroscopy. The smaller rd, when combined with the electronic isotope shift, yields a "small" proton radius rp, similar to the one from muonic hydrogen, amplifying the proton radius puzzle.
Accurate knowledge of the charge and Zemach radii of the proton is essential, not only for understanding its structure but also as input for tests of bound-state quantum electrodynamics and its ...predictions for the energy levels of hydrogen. These radii may be extracted from the laser spectroscopy of muonic hydrogen (μp, that is, a proton orbited by a muon). We measured the $2{\mathrm{S}}_{1/2}^{\mathrm{F}=0}-2{\mathrm{P}}_{3/2}^{\mathrm{F}=1}$ transition frequency in μp to be 54611.16(1.05) gigahertz (numbers in parentheses indicate one standard deviation of uncertainty) and reevaluated the $2{\mathrm{S}}_{1/2}^{\mathrm{F}=1}-2{\mathrm{P}}_{3/2}^{\mathrm{F}=1}$ transition frequency, yielding 49881.35(65) gigahertz. From the measurements, we determined the Zemach radius, r Z = 1.082(37) femtometers, and the magnetic radius, r M = 0.87(6) femtometer, of the proton. We also extracted the charge radius, r E = 0.84087(39) femtometer, with an order of magnitude more precision than the 2010-CODATA value and at 7σ variance with respect to it, thus reinforcing the proton radius puzzle.
Kα,β X-ray lines from photon excitation were measured in selected elements from Mg to Cu using a high-resolution double-crystal X-ray spectrometer with a proportional counter, and the Kβ/Kα intensity ...ratio for each element was obtained, after correcting for self-absorption, detection efficiency, and crystal reflectance. This intensity ratio increases rapidly from Mg to Ca but, in the 3d elements region, the increase becomes slower. This is related to the intensity of the Kβ line involving valence electrons. The slow increase of this ratio in the 3d elements region is thought to be due to the correlation between 3d and 4s electrons. Moreover, the chemical shifts, FWHM, asymmetry indices, and Kβ/Kα intensity ratios of the Cr compounds, due to different valences, were also investigated using the same double-crystal X-ray spectrometer. The chemical effects were clearly observed, and the Kβ/Kα intensity ratio was found to be compound-dependent for Cr.
In multiconfiguration Dirac–Hartree–Fock (MCDHF) calculations, there is a strong coupling between the localization of the orbital set and the configuration state function (CSF) expansion used to ...determine it. Furthermore, it is well known that an orbital set resulting from calculations, including CSFs describing core–core correlation and other effects, which aims to lower the weighted energies of a number of targeted states as much as possible, may be inadequate for building CSFs that account for correlation effects that are energetically unimportant but decisive for computed properties, e.g., hyperfine structures or transition rates. This inadequacy can be traced in irregular or oscillating convergence patterns of the computed properties as functions of the increasing orbital set. In order to alleviate the above problems, we propose a procedure in which the orbital set is obtained by merging several separately optimized, and mutually non-orthogonal, orbital sets. This computational strategy preserves the advantages of capturing electron correlation on the total energy through the variational MCDHF method and allows to target efficiently the correlation effects on the considered property. The orbital sets that are merged are successively orthogonalized against each other to retain orthonormality. The merged orbital set is used to build CSFs that efficiently lower the energy and also adequately account for the correlation effects that are important for the property. We apply the procedure to compute the hyperfine structure constants for the 1s22s2S1/2 and 1s22p2P1/2,3/2o states in 7Li and show that it leads to considerably improved convergence patterns with respect to the increasing orbital set compared to standard calculations based on a single orbital set, energy-optimized in the variational procedure. The perspectives of the new procedure are discussed in a broader context in the summary.
A superconducting transition-edge sensor (TES) microcalorimeter is an ideal X-ray detector for experiments at accelerator facilities because of good energy resolution and high efficiency. To study ...the performance of the TES detector with a high-intensity pulsed charged-particle beam, we measured X-ray spectra with a pulsed muon beam at the Japan Proton Accelerator Research Complex (J-PARC) in Japan. We found substantial temporal shifts of the X-ray energy correlated with the arrival time of the pulsed muon beam, which was reasonably explained by pulse pileup due to the incidence of energetic particles from the initial pulsed beam.
With metallic-magnetic calorimeters (MMCs), promising detectors for high-precision X-ray spectrometry in atomic and fundamental physics experiments are available. In this work, we present a pilot ...experiment based on a maXs-30 type MMC-spectrometer for recording X-rays emitted in collisions of lithium-like uranium ions with a molecular nitrogen gas jet in the internal target of the ESR storage ring of the GSI. Sample spectra have been measured, and a multitude of X-ray transitions have been unambiguously identified. As a first test and for comparison with data recorded at an EBIT, the 2s Lamb shift in lithium-like uranium was estimated.
We, the QUARTET Collaboration, propose an experiment to measure the nuclear charge radii of light elements with up to 20 times higher accuracy. These are essential both for understanding nuclear ...physics at low energies, and for experimental and theoretical applications in simple atomic systems. Such comparisons advance the understanding of bound-state quantum electrodynamics and are useful for searching for new physics beyond the Standard Model. The energy levels of muonic atoms are highly susceptible to nuclear structure, especially to the mean square charge radius. The radii of the lightest nuclei (with the atomic number, Z=1,2) have been determined with high accuracy using laser spectroscopy in muonic atoms, while those of medium mass and above were determined using X-ray spectroscopy with semiconductor detectors. In this communication, we present a new experiment, aiming to obtain precision measurements of the radii of light nuclei 3≤Z≤10 using single-photon energy measurements with cryogenic microcalorimeters; a quantum-sensing technology capable of high efficiency with outstanding resolution for low-energy X-rays.
The toolbox for material characterization has never been richer than today. Great progress with all kinds of particles and interaction methods provide access to nearly all properties of an object ...under study. However, a tomographic analysis of the subsurface region remains still a challenge today. In this regard, the Muon Induced X-ray Emission (MIXE) technique has seen rebirth fueled by the availability of high intensity muon beams. We report here a study conducted at the Paul Scherrer Institute (PSI). It demonstrates that the absence of any beam time-structure leads to low pile-up events and a high signal-to-noise ratio (SNR) with less than one hour acquisition time per sample or data point. This performance creates the perspective to open this technique to a wider audience for the routine investigation of non-destructive and depth-sensitive elemental compositions, for example in rare and precious samples. Using a hetero-structured sample of known elements and thicknesses, we successfully detected the characteristic muonic X-rays, emitted during the capture of a negative muon by an atom, and the gamma-rays resulting from the nuclear capture of the muon, characterizing the capabilities of MIXE at PSI. This sample emphasizes the quality of a continuous beam, and the exceptional SNR at high rates. Such sensitivity will enable totally new statistically intense aspects in the field of MIXE, e.g., elemental 3D-tomography and chemical analysis. Therefore, we are currently advancing our proof-of-concept experiments with the goal of creating a full fledged permanently operated user station to make MIXE available to the wider scientific community as well as industry.