Display omitted
•The increasing occurrence of micropollutants poses threats to water reclamation.•Removal in MBRs relate to sorption, biodegradation and membrane separation.•Sorption efficiency ...depends on the hydrophobicity and ionogenicity of compounds.•SRT, HRT, ORP, etc. influence the biological degradation performance.•Efficient membrane separation can be achieved by technology integration.
Membrane bioreactors (MBRs) have attracted attention in water reclamation as a result of the recent technical advances and cost reduction in membranes. However, the increasing occurrence of micropollutants in wastewaters has posed new challenges. Therefore, we reviewed the current state of research to identify the outstanding needs in this field. In general, the fate of micropollutants in MBRs relates to sorption, biodegradation and membrane separation processes. Hydrophobic, nonionized micropollutants are favorable in sorption, and the biological degradation shows higher efficiency at relatively long SRTs (30–40 days) and HRTs (20–30 h), as a result of co-metabolism, metabolism and/or ion trapping. Although the membrane rejection rates for micropollutants are generally minor, final water quality can be improved via combination with other technologies. This review highlights the challenges and perspectives that should be addressed to facilitate the extended use of MBRs for the removal of micropollutants in water reclamation.
This study provides a new approach of electrode dependent anaerobic ammonium oxidation (electroanammox) in microbial fuel cell (MFC) integrated hybrid constructed wetlands (CWs). The study was ...carried out in three CWs, each with a horizontal flow (HF) followed by a vertical upflow (VUF). Two of the CWs were integrated with MFC, one was operated in closed circuit (CL) mode and the other in open circuit (OP) mode to determine the influence of electron transfer through an external electrical circuit. The initial nitrogen and carbon concentration were 40 mg/l and 880 mg/l respectively. The total nitrogen (TN), NH4+-N, TOC and COD removal achieved in CW-MFC-CL were 90.0 ± 1.15%, 94.4 ± 0.75%, 64.8 ± 3.0% and up to 99.5 ± 3.4%, respectively. The TN and NH4+-N removal in CW-MFC-CL was 20.0% and 13.6% higher than normal CW. Maximum current density achieved in CW-MFC-HF was of 75 mA/m3 and in CW-MFC-VUF was 156 mA/m3. Furthermore, the study revealed that even at low microbiological biomass, an MFC integrated CW operating in closed circuit gave higher removal of NH4+-N and COD than the normal CW and open circuit CW-MFC. Microbiological analysis shows the presence of already known nitrifier and denitrifer which indicates their role in electrode dependent nitrogen removal.
Display omitted
•Conductive material/electrode dependent anaerobic ammonium oxidation is possible.•Electroannamox process is a new way performing anaerobic ammonium oxidation.•Conductive material dependent oxidation produces less but efficient biomass.•Use of conductive material improved treatment performance of constructed wetland.
Constantly changing and evolving social, economic, political, and environmental landscapes create new uncertainties in urban water supplies. These uncertainties surrounding urban water management ...have been captured using various scenario analysis techniques, which have been developed to envision plausible futures. Although past review papers have conducted broad reviews on water-related issues and water management generally, there has been a lack of attention to urban water management specifically. The growing uncertainty surrounding urban water management systems necessitates a focused review specifically aimed at the use of scenarios in urban water management. Using a comprehensive typology, a systematic review is presented to empirically investigate the necessary dimensions of urban water management scenario assessment. Urban water management scenario studies that exclusively employ qualitative methods, as well as urban water management studies that employ qualitative methods with quantitative techniques, are reviewed against the comprehensive typology. By aligning the reviewed scenarios with the dimensions in the typology, some important gaps in the current literature were identified. The need for: (i) transparency in scenario development and analysis processes, (ii) inclusion of surprises and extreme events, (iii) validation efforts and (iv) considering the impact phase of a scenario process. Recommendations are proposed to address the above gaps in current urban water scenarios literature, providing a path for future scenario analysis in urban water management.
Secondary disinfectants, such as chlorine and chloramine, have been widely applied to minimise microbial risks in drinking water during distribution. Key challenges have included the maintenance of ...stable concentrations of disinfectant residuals and the control of disinfection by-products that may form as a consequence of residual decay processes. Many factors may influence disinfectant residual stability and the consequential formation of by-products. Thus predictions of disinfectant stability and by-product formation are multifactorial problems, complete with numerous complications of parameter co-dependence and feedback amplification of some key parameters. The aim of this review was to derive an understanding of how disinfectant residual stability in drinking water distribution systems is impacted by various influencing factors such as water quality and operational parameters. Factors known to influence disinfectant stability and by-product formation were critically reviewed. A systematic review method was applied to identify 1809 journal articles published in the two decades from January 1998 to December 2017. From the initial screening, 161 papers were selected for detailed assessment. Important factors were identified to include temperature, water age, piping material, corrosion products, pH, hydraulic condition, disinfectant residual type and dosage and microbial activity. Microbial activity is a particularly complex parameter on which to base predictions since many factors are known to influence the degree and nature of such activity. These include temperature, water age, piping material, corrosion products, nutrients, natural organic matter, hydraulic condition and disinfectant residual type and dosage. Disinfectant types and dosages were found to be among the most important factors. Many knowledge gaps and research needs still remain, including the need for a more complete understanding of the factors that influence the production of nitrogenous disinfection by-products.
Display omitted
•Factors intricately affect disinfectant decay and disinfection byproducts formation.•Influencing factors may lead to positive feedback loops on disinfectant stability.•Microbial activity is the most influencing factor among all other factors.•Pipe material is a major factor (in)directly affecting disinfectant stability.•Proposal for predicting disinfectant residual stability by a Bayesian Network model.
To convene a multidisciplinary panel of breast experts to examine the relationship between margin width and ipsilateral breast tumor recurrence (IBTR) and develop a guideline for defining adequate ...margins in the setting of breast conserving surgery and adjuvant radiation therapy.
A multidisciplinary consensus panel used a meta-analysis of margin width and IBTR from a systematic review of 33 studies including 28,162 patients as the primary evidence base for consensus.
Positive margins (ink on invasive carcinoma or ductal carcinoma in situ) are associated with a 2-fold increase in the risk of IBTR compared with negative margins. This increased risk is not mitigated by favorable biology, endocrine therapy, or a radiation boost. More widely clear margins than no ink on tumor do not significantly decrease the rate of IBTR compared with no ink on tumor. There is no evidence that more widely clear margins reduce IBTR for young patients or for those with unfavorable biology, lobular cancers, or cancers with an extensive intraductal component.
The use of no ink on tumor as the standard for an adequate margin in invasive cancer in the era of multidisciplinary therapy is associated with low rates of IBTR and has the potential to decrease re-excision rates, improve cosmetic outcomes, and decrease health care costs.
The biological removal of 38 trace organics (pharmaceuticals, endocrine disruptors, personal care products and pesticides) was studied in an anaerobic membrane bioreactor (AnMBR). This work presents ...complete information on the different removal mechanisms involved in the removal of trace organics in this process. In particular, it is focused on advanced characterization of the relative amount of TO accumulated within the fouling layers formed on the membranes. The results show that only 9 out of 38 compounds were removed by more than 90% while 23 compounds were removed by less than 50%. These compounds are therefore removed in an AnMBR biologically and partially adsorbed and retained by flocs and the deposition developed on the membranes, respectively. A total amount of 288 mg of trace organics was retained per m(2) of membrane, which were distributed along the different fouling layers. Among the trace organics analyzed, 17α-ethynylestradiol, estrone, octylphenol and bisphenol A were the most retained by the fouling layers. Among the fouling layers deposited on the membranes, the non-readily detachable layer has been identified as the main barrier for trace organics.
In this study, a direct contact membrane distillation (MD) unit was integrated with an anaerobic membrane bioreactor (AnMBR) to simultaneously recover energy and produce high quality water for reuse ...from wastewater. Results show that AnMBR could produce 0.3–0.5L/g CODadded biogas with a stable methane content of approximately 65%. By integrating MD with AnMBR, bulk organic matter and phosphate were almost completely removed. The removal of the 26 selected trace organic contaminants by AnMBR was compound specific, but the MD process could complement AnMBR removal, leading to an overall efficiency from 76% to complete removal by the integrated system. The results also show that, due to complete retention, organic matter (such as humic-like and protein-like substances) and inorganic salts accumulated in the MD feed solution and therefore resulted in significant fouling of the MD unit. As a result, the water flux of the MD process decreased continuously. Nevertheless, membrane pore wetting was not observed throughout the operation.
Display omitted
•Stable biogas production and organic removal by AnMBR were observed.•MD complemented AnMBR treatment well to enhance contaminant removal.•AnMBR-MD achieved 76% to complete removal of all 26 TrOCs investigated here.•Foulants accumulated in MD feed and thus induced MD membrane fouling.
A two-stage hybrid Constructed Wetland (CW) integrated with a microbial fuel cell (MFC), and microbial electrolysis cell (MEC) has been assessed for treatment performance and clogging assessment and ...further compared with CW. The CW-MEC was operated with applied potential to the working electrode and compared with the performance of naturally adapted redox potential of the CW-MFC system. A complex synthetic municipal wastewater was used during the study, which was composed of trace metals, organics, inorganics, and dye. The study demonstrated that providing a constant potential to the working electrode in CW-MEC has resulted in high treatment performance and reduced sludge generation. The maximum chemical oxygen demand (COD), ammonium (NH4+), and phosphate (PO43−) removal achieved during treatment by CW-MEC at 24 h hydraulic retention time was 89 ± 6%, 72 ± 6% and 93 ± 2%, respectively. ICP-MS results indicated that trace metal removals were also higher in CW-MEC than in CW alone (p < 0.05). At the end of the experiment, significant volumetric change (total volume of the microcosm) occurred in CW (1.3 L), which indicates high sludge generation, whereas it was lesser in CW-MEC (0.3 L) and in CW-MFC (0.5 L). Further, Energy Dispersive X-ray (EDX) spectroscopy results indicated low levels of metal precipitation in the CW-MEC system. Based on the Shannon diversity index, the CW-MEC was assessed to be characterised by high species richness and diversity. The observations from this study indicate that the applied potential at the working electrode has a significant impact on treatment performance and clogging behaviour of the system.
Display omitted
•Redox potential plays a significant role in CW-MET.•Applied potential regulates treatment performance of CW-MET.•Constructed wetland-microbial electrolysis cell inhabited with high microbial diversity.•Redox gradient influences clogging behaviour of CW-MET.•Less metal precipitation occurs due to applied potential.
Reverse osmosis concentrate (ROC) generated as a waste stream during reverse osmosis treatment of reclaimed wastewater, presents significant disposal challenges. This is because it causes ...environmental pollution when it is disposed to lands and natural water bodies. A long-term dynamic adsorption experiment was conducted by passing ROC from a wastewater reclamation plant, firstly through a granular activated carbon (GAC) column, and subsequently through an anion exchange resin (Purolite) column, for the removal of two major ROC pollutants, namely dissolved organic carbon (DOC) and microorganic pollutants (MOP). GAC removed most of the smaller-sized low molecular weight neutrals and building block fractions as well as the hydrophobic fraction of DOC with much less removal by the subsequent Purolite column. In contrast, the humics fraction was less well removed by the GAC column; however, Purolite column removed all that was remaining of this fraction. This study demonstrated that combining adsorbents having different affinities towards a variety of DOC fractions constitute an effective method of taking advantage of their different properties and achieving larger DOC removals. Almost 100% of all 17 MOPs were removed by the GAC column, even after 2880 bed volumes of continuous use. This contrasted with the DOC fractions’ removal which was much lower.
•Combined GAC + anion exchange resin columns removed all DOC fractions of ROC.•GAC removed all 17 microorganic pollutants at 2880 BV of use but not DOC.•GAC had higher affinity for smaller-sized DOC fractions and hydrophobic fraction.•Anion exchange resin (Purolite) had higher affinity for humics fraction of DOC.