A high-intensity, low-emittance atomic muonium (M
=\mu^+ + e^-
=
μ
+
+
e
−
)
beam is being developed, which would enable improving the precision of
M spectroscopy measurements, and may allow a direct ...observation of the
M gravitational interaction. Measuring the free fall of M atoms
would be the first test of the weak equivalence principle using
elementary antimatter (
\mu^+
μ
+
)
and a purely leptonic system. Such an experiment relies on the high
intensity, continuous muon beams available at the Paul Scherrer
Institute (PSI, Switzerland), and a proposed novel M source. In this
paper, the theoretical motivation and principles of this experiment are
described.
The muX project Wauters, Frederik; Knecht, Andreas
SciPost physics proceedings,
09/2021
5
Journal Article
Recenzirano
Odprti dostop
The project is conducting a series of muonic X-ray measurements in medium- and high-Z nuclei at PSI, utilizing a high-purity germanium detector array, in-beam muon detectors, and a modern digital ...data-acquisition system. A novel hydrogen target for muon transfer was developed, enabling measurements with as little as a few micrograms of target material. First measurements with radioactive Cm and Ra targets were conducted, aimed at determining their nuclear charge radii. These serve as important input for upcoming atomic parity violation experiments. The apparatus is also used to perform a feasibility study of an atomic parity violation experiment with the
2s-1s
2
s
−
1
s
muonic X-ray transition. In addition, the setup has been made available for a wider range of nuclear, particle, and solid-state physics measurements.
We, the QUARTET Collaboration, propose an experiment to measure the nuclear charge radii of light elements with up to 20 times higher accuracy. These are essential both for understanding nuclear ...physics at low energies, and for experimental and theoretical applications in simple atomic systems. Such comparisons advance the understanding of bound-state quantum electrodynamics and are useful for searching for new physics beyond the Standard Model. The energy levels of muonic atoms are highly susceptible to nuclear structure, especially to the mean square charge radius. The radii of the lightest nuclei (with the atomic number, Z=1,2) have been determined with high accuracy using laser spectroscopy in muonic atoms, while those of medium mass and above were determined using X-ray spectroscopy with semiconductor detectors. In this communication, we present a new experiment, aiming to obtain precision measurements of the radii of light nuclei 3≤Z≤10 using single-photon energy measurements with cryogenic microcalorimeters; a quantum-sensing technology capable of high efficiency with outstanding resolution for low-energy X-rays.
A
knob bow fibula (Bügelknopffibel)
of the
Leutkirch
type, which typologically belongs to the second half of the 4th and early 5th century CE, was excavated in 2018 in the Roman city of Augusta ...Raurica, present-day Kaiseraugst (AG, Switzerland). This was analyzed for the first time for its elemental composition by using the non-destructive technique of Muon Induced X-ray Emission (MIXE) in the continuous muon beam facility at the Paul Scherrer Institute (PSI). In the present work, the detection limit is 0.4 wt% with
∼
1.5 hours of measurement time. The fibula was measured at six different positions, at a depth of 0.3–0.4 mm inside the material. The experimental results show that the fibula is made of bronze, containing the main elements copper (Cu), zinc (Zn), tin (Sn) and lead (Pb). The compositional similarities/differences between different parts of the fibula reveal that it was manufactured as two “workpieces”. One workpiece consists of the knob (13.0±0.6 wt% Pb), bow (11.9±0.4 wt% Pb) and foot (12.5 ± 0.9 wt% Pb). These show a higher Pb content, suggesting a cast bronze. The spiral (3.2 ± 0.2 wt% Pb), which is part of the other workpiece, has a comparatively lower Pb content, suggesting a forged bronze.
The high intensity proton accelerator complex (HIPA) at the Paul Scherrer Institute (PSI) delivers a 590 MeV CW proton beam with currents up to 2.4 mA (1.4 MW). Besides two spallation targets for ...thermal/cold neutrons (SINQ) and for ultracold neutrons (UCN), the beam feeds two meson production targets Target M and Target E. The targets consist of graphite wheels of effective thickness 5 mm (M) and 40/60 mm (E). The target stations M and E are of quite different design; however, both of them rotate at 1 Hz to dissipate the heat (20 kW/mA for the 40 mm target E) efficiently. Recent progress was made by a new type of bearings and a new target geometry able to increase the rate of surface muons by up to 50 %. This is also foreseen for the upgrade of the target station M within the High Intensity Muon Beam (HIMB) initiative aiming to increase the surface muons available for experiment by two orders of magnitude. HIMB is part of IMPACT (Isotope and Muon Production with Advanced Cyclotron and Target Technology), an application for the Swiss Roadmap of Research Infrastructure.
The toolbox for material characterization has never been richer than today. Great progress with all kinds of particles and interaction methods provide access to nearly all properties of an object ...under study. However, a tomographic analysis of the subsurface region remains still a challenge today. In this regard, the Muon Induced X-ray Emission (MIXE) technique has seen rebirth fueled by the availability of high intensity muon beams. We report here a study conducted at the Paul Scherrer Institute (PSI). It demonstrates that the absence of any beam time-structure leads to low pile-up events and a high signal-to-noise ratio (SNR) with less than one hour acquisition time per sample or data point. This performance creates the perspective to open this technique to a wider audience for the routine investigation of non-destructive and depth-sensitive elemental compositions, for example in rare and precious samples. Using a hetero-structured sample of known elements and thicknesses, we successfully detected the characteristic muonic X-rays, emitted during the capture of a negative muon by an atom, and the gamma-rays resulting from the nuclear capture of the muon, characterizing the capabilities of MIXE at PSI. This sample emphasizes the quality of a continuous beam, and the exceptional SNR at high rates. Such sensitivity will enable totally new statistically intense aspects in the field of MIXE, e.g., elemental 3D-tomography and chemical analysis. Therefore, we are currently advancing our proof-of-concept experiments with the goal of creating a full fledged permanently operated user station to make MIXE available to the wider scientific community as well as industry.
Currently, PSI delivers the most intense continuous muon beam in the world with up to a few 10
8
µ
+
/s. The High-Intensity Muon Beams (HIMB) project is developing a new target station and muon ...beamlines able to deliver 10
10
µ
+
/s, with a huge impact for low-energy, high-precision muon experiments. While the next generation of proton drivers with beam powers in excess of the currently achieved 1.4 MW still require significant research and development, the focus of HIMB is to improve the surface muon yield with a new target geometry and to increase capture and transmission with a solenoid-based beamline in order to reach a total efficiency of approximately 10 %. We present the current status of the HIMB project.
The gravitational acceleration of antimatter, g ¯ , has yet to be directly measured; an unexpected outcome of its measurement could change our understanding of gravity, the universe, and the ...possibility of a fifth force. Three avenues are apparent for such a measurement: antihydrogen, positronium, and muonium, the last requiring a precision atom interferometer and novel muonium beam under development. The interferometer and its few-picometer alignment and calibration systems appear feasible. With 100 nm grating pitch, measurements of g ¯ to 10%, 1%, or better can be envisioned. These could constitute the first gravitational measurements of leptonic matter, of 2nd-generation matter, and possibly, of antimatter.
The energy levels of hydrogen-like atomic systems can be calculated with great precision. Starting from their quantum mechanical solution, they have been refined over the years to include the ...electron spin, the relativistic and quantum field effects, and tiny energy shifts related to the complex structure of the nucleus. These energy shifts caused by the nuclear structure are vastly magnified in hydrogen-like systems formed by a negative muon and a nucleus, so spectroscopy of these muonic ions can be used to investigate the nuclear structure with high precision. Here we present the measurement of two 2S-2P transitions in the muonic helium-4 ion that yields a precise determination of the root-mean-square charge radius of the α particle of 1.67824(83) femtometres. This determination from atomic spectroscopy is in excellent agreement with the value from electron scattering
, but a factor of 4.8 more precise, providing a benchmark for few-nucleon theories, lattice quantum chromodynamics and electron scattering. This agreement also constrains several beyond-standard-model theories proposed to explain the proton-radius puzzle
, in line with recent determinations of the proton charge radius
, and establishes spectroscopy of light muonic atoms and ions as a precise tool for studies of nuclear properties.