Abstract
Objective
To study the association between insulin-like growth factor 1 (IGF-1) and blood pressure in children, in particular, the potential interaction with the serum calcium-phosphorus ...product (Ca*P).
Methods
A longitudinal study included 521 children (age 8.8 ± 0.1) from northeastern Spain, of whom 158 were followed-up after 5 years. IGF-1, insulin-like growth factor-binding protein 3 (IGFBP-3), and serum calcium and phosphorus were measured at baseline. Anthropometric (body-mass index BMI and waist) and cardiometabolic variables (systolic SBP and diastolic blood pressure), pulse pressure, insulin, homeostatic model assessment of insulin resistance HOMA-IR, high-density lipoprotein HDL-cholesterol, and triglycerides) were assessed at baseline and at the end of follow-up. Statistical analysis included Pearson correlations followed by multivariable linear regression analyses.
Results
Baseline IGF-1 and IGF-1/IGFBP-3 molar ratio positively correlated with baseline and follow-up BMI, waist, SBP, pulse pressure, insulin, HOMA-IR and triglycerides (r 0.138-0.603; all P < 0.05). The associations with SBP were stronger with increasing Ca*P (r 0.261-0.625 for IGF-1; and r 0.174-0.583 for IGF-1/IGFBP-3). After adjusting for confounding variables, baseline IGF-1 and IGF-1/IGFBP-3 remained independently associated with both baseline and follow-up SBP in children in the highest Ca*P tertile (β = 0.245-0.381; P < 0.01; model R2 = 0.246-0.566).
Conclusions
Our results suggest that IGF-1 in childhood is an independent predictor of SBP in apparently healthy children, especially in those with high Ca*P levels.
PurposeTo evaluate the refractive and visual outcomes of eyes implanted with monofocal, optimized, aspheric, hydrophobic acrylic intraocular lenses (IOL) following cataract surgery.MethodsThe study ...assessed 55 eyes implanted with CT LUCIA® 621P IOLs (Carl Zeiss Meditec AG, Jena, Germany) at 3-months postsurgery. The main outcome measures were refractive error, monocular corrected distance visual acuity (CDVA), monocular uncorrected distance visual acuity (UDVA), photopic and mesopic contrast sensitivity, and wavefront aberrations. Patients were asked to complete the Catquest-9SF questionnaire.ResultsAt 3 months, the cumulative Snellen visual acuity was 20/20 in 94.55% of eyes and 20/25 or better in 100%. The difference between the UDVA and CDVA was either the same (70.91%) or better (29.09%) in all eyes. The mean Snellen decimal UDVA and DCVA were 1.07 ± 0.15 and 1.13 ± 0.11, respectively. The safety and efficacy indexes were 1.48 and 1.40, respectively. 47.27% of eyes showed a spherical equivalent ±0.13 D, with 92.73% of the eyes were within ±0.50 D and all eyes were within ±1.00 D. The mean spherical equivalent was -0.03 ± 0.30 D and the mean refractive cylinder -0.36 ± 0.34 D. The log photopic and mesopic contrast sensitivity functions were good and similar for all spatial frequencies. All patients reported being either fairly satisfied (score 3) or very satisfied (score 4) with their vision (mean = 3.64 ± 0.49). No intra- and postoperative complications were reported during the 3 months of follow-up.ConclusionThe current study demonstrates that excellent visual and refractive outcomes, as well as patient satisfaction, can be achieved after cataract surgery with optimized, aspheric CT LUCIA 621P monofocal IOLs.