Underwater EMR is an alternative way to have nonpedunculated colorectal lesions lifted before being resected. The endoscopist takes advantage of the behavior of mucosal lesions floating away from the ...muscular layer, once immersed in liquid. We performed a systematic review with meta-analysis to evaluate the efficacy and safety of this technique.
Electronic databases (Medline, Scopus, EMBASE) were searched up to May 2018. Full articles including patients with colorectal lesions resected by the underwater EMR technique were eligible. The complete resection (primary outcome), en bloc resection, recurrence, and adverse event rates were pooled by means of a random or fixed-effect model.
Ten studies were eligible, providing data on 508 lesions removed from 433 patients (male/female = 239/194; mean age range 62.2-75.0 years). Six studies were performed in the United States and the other in Europe; 7 studies were prospective. The specific indications for performing underwater EMR varied widely across studies. The complete resection rate was 96.36% (95% confidence interval CI, 91.77-98.44), with a rate of en bloc resection of 57.07% (95% CI, 43.20%-69.91%). The recurrence rate was 8.82% (95% CI, 5.78-13.25) in a mean endoscopy surveillance period of 7.7 months (range 4-15 months). The postprocedural bleeding rate was 2.85% (95% CI, 1.64-4.90). Bleeding during the procedure was always mild and was considered as part of the procedure in all series. The overall adverse event rate was 3.31% (95% CI, 1.97%-5.52%). No cases of perforation were reported.
According to the results of this systematic review, underwater EMR appears to be an effective and extremely safe technique for resecting nonpolypoid colorectal lesions.
Display omitted
Hot Polypectomy: A Cautionary Tale? Lamonaca, Laura; Belletrutti, Paul J.; Repici, Alessandro
Gastroenterology (New York, N.Y. 1943),
August 2019, 2019-Aug, 2019-08-00, 20190801, Letnik:
157, Številka:
2
Journal Article
Submucosal injection is generally required for both endoscopic-mucosal resection (EMR) and submucosal dissection (ESD). SIC-8000 (Eleview™) is a new FDA 510(k) cleared and CE marked liquid ...composition for submucosal injection, containing a biocompatible polymer as a cushioning agent.
The aim of this randomized study was to compare Eleview with saline solution when performing upper- and lower-GI EMR/ESD in a porcine model.
EMR/ESD procedures were performed in a total of 10 white domestic pigs comparing Eleview vs. NaCl 0.9% containing methylene blue at 0.001% (control solution) as submucosal solution to be injected. Animals were randomized between EMR (22 procedures) and ESD (22 procedures) and between upper- (8 animals) and lower-(2 animals) GI procedures. All procedures were performed aiming for a resection size of 1 cm × 1 cm for EMR and 2 cm × 2 cm for ESD. Volume of injected fluid, number of injections, time of resection, technical success, en-bloc resection, and adverse events were collected. Endoscopic surveillance was conducted each week for 4 weeks after the EMR/ESD, including biopsies on the margins of resection sites at week-1 of follow-up. After four weeks, pigs were sacrificed and necropsy performed.
Overall, 22 EMR and 22 ESD were performed in 10 live pigs. The average total volume needed for EMR and ESD was statistically significantly lower with Eleview as compared with control solution for both of the techniques (EMR: 5.6 ± 3.4 ml vs. 11.5 ± 6.7 ml; p = 0.02; ESD: 19.0 ± 10.0 ml vs. 36.3 ± 16.9 ml; p = 0.02). The rate of adverse events was statistically significantly lower in the Eleview than in the control group (2/26, 7.7% vs. 6/18, 33.3%; p = 0.03), but most of them were minor. No difference between Eleview and control solution was found in the rate of technical success (EMR: 11/13, 84.6% vs. 7/9, 77.8%; p = 0.7; ESD: 13/13, 100% vs. 9/9, 100%; p = 1), en-bloc resection (EMR: 6/13, 46.2% vs. NaCl: 5/9, 55.6%; p = 0.06; ESD: 12/13, 92.3% vs. 8/9, 88.9%; p = 0.8), and time of resection (EMR: 9.1 ± 7.75 min vs. 9.4 ± 9.6 min; p = NS; ESD: 38.4 ± 17.2 min vs. 40.2 ± 19.1 min; p = NS). At endoscopic follow up and necropsy, no difference in the process of healing of post-endoscopic ulcer and in the histological inflammation at the site of resection was shown between the two groups.
The new submucosal injection composition Eleview appeared to be an effective alternative to saline solution for submucosal injection for EMR/ESD, resulting in a substantial reduction of the volume administered to achieve an adequate lifting. No signs of adverse local or distant tissue reaction to Eleview were found at long-term follow up.