Multiple therapeutic modalities including surgery and rigid and flexible endoscopy have been adopted to manage Zenker's diverticulum (ZD). Minimally invasive flexible endoscopic septotomy (FES) ...techniques have been increasingly favored over the past 20 years; however, long-term data are still scanty. The aim of this study is to evaluate early and long-term outcomes of FES for naive ZD in a single-center setting.
From 2010 to 2017, ZD patients treated with FES were included in a prospectively maintained database (NCT03948438). Those who had already been treated surgically or endoscopically were excluded from the analysis. The Dakkak and Bennett dysphagia scale was used to rate the dysphagia. Persistent complete or near-complete resolution of symptoms (Dakkak and Bennett 0 or 1) was defined as clinical success. Postprocedural adverse events were reported according to ASGE lexicon.
Overall, 256 consecutive patients were treated. Mean pouch size was 29.8 ± 11.3 mm. The procedure was successfully completed in all scheduled patients, with an early clinical success of 96.1%. Adverse events occurred in 3.5% (9/256) of patients. Eight of them were mild/moderate with no fatal events, whereas one patient required surgery. Recurrences occurred in 31.3% (80/256) of treated patients after a mean time of 9 ± 3 months and 95% of recurrences were treated by a second FES. At an average follow-up of 5.5 years, 95.3% of patients were asymptomatic after a mean number of 1.3 procedures.
FES is a safe and effective treatment modality for patients with ZD. Recurrence rate is significant; however, endoscopic reintervention is associated with long-term relief of dysphagia.
To date, no scale has been validated to assess bubbles associated with bowel preparation. This study aimed to develop and assess the reliability of a novel scale - the Colon Endoscopic Bubble Scale ...(CEBuS).
This was a multicenter, prospective, observational study with two online evaluation phases of 45 randomly distributed still colonoscopy images (15 per scale grade). Observers assessed images twice, 2 weeks apart, using CEBuS (CEBuS-0 - no or minimal bubbles, covering < 5 % of the surface; CEBuS-1 - bubbles covering 5 %-50 %; CEBuS-2 - bubbles covering > 50 %) and reporting the clinical action (do nothing; wash with water; wash with simethicone).
CEBuS provided high levels of agreement both in evaluation Phase 1 (4 experts) and Phase 2 (6 experts and 13 non-experts), with almost perfect intraobserver reliability: kappa 0.82 (95 % confidence interval 0.75-0.88) and 0.86 (0.85-0.88); interobserver agreement - intraclass correlation coefficient (ICC) 0.83 (0.73-0.89) and 0.90 (0.86-0.94). Previous endoscopic experience had no influence on agreement among experts vs. non-experts: kappa 0.86 (0.80-0.91) vs. 0.87 (0.84-0.89) and ICC 0.91 (0.87-0.94) vs. 0.90 (0.86-0.94), respectively. Interobserver agreement on clinical action was ICC 0.63 (0.43-0.78) in Phase 1 and 0.77 (0.68-0.84) in Phase 2. Absolute agreement on clinical action per scale grade was 85 % (82-88) for CEBuS-0, 21 % (16-26) for CEBuS-1, and 74 % (70-78) for CEBuS-2.
CEBuS proved to be a reliable instrument to standardize the evaluation of colonic bubbles during colonoscopy. Assessment in daily practice is warranted.
Intraparenchymal lung masses inaccessible through bronchoscopy or endobronchial ultrasound guidance pose a diagnostic challenge. Furthermore, some fragile or hypoxic patients may be poor candidates ...for transbronchial approaches. Endoscopic ultrasound-guided fine-needle aspiration/biopsy (EUS-FNA/FNB) offers a potential diagnostic approach to lung cancers adjacent to the esophagus. We aimed to evaluate the feasibility, accuracy, and safety of trans-esophageal EUS-FNA/FNB for tissue sampling of pulmonary nodules.
We retrospectively analyzed data from patients with pulmonary lesions who underwent EUS-FNA/FNB between March 2015 and August 2021 at eight Italian endoscopic referral centers.
A total of 47 patients (36 male; mean age 64.47 ± 9.05 years) were included (22 EUS-FNAs and 25 EUS-FNBs). Overall diagnostic accuracy rate was 88.9% (76.3-96.2%). The sensitivity and diagnostic accuracy were superior for EUS FNB sampling versus EUS-FNA (100% vs. 78.73%); P = 0.05, and (100% vs. 78.57%); P = 0.05, respectively. Additionally, sample adequacy was superior for EUS-FNB sampling versus EUS-FNA (100% vs. 78.5%); P = 0.05. Multivariate logistic regression analysis for diagnostic accuracy showed nodule size at the cutoff of 15 mm (OR 2.29, 1.04-5.5, P = 0.05) and use of FNB needle (OR 4.33, 1.05-6.31, P = 0.05) as significant predictors of higher diagnostic accuracy. There were no procedure-related adverse events.
This study highlights the efficacy and safety of EUS-FNA/FNB as a minimally invasive procedure for diagnosing and staging peri-esophageal parenchymal lung lesions. The diagnostic yield of EUS-FNB was superior to EUS-FNA.