The ability to quantify synaptic density in vivo in human adults and adolescents is of vital importance to understanding neuropsychiatric disorders. Here, we performed whole-body scans to determine ...organ radiation dosimetry of
11
C-UCB-J in humans.
Methods
Dynamic whole-body PET scans were performed in four healthy adults after injection of
11
C-UCB-J. Regions of interest (ROIs) were drawn manually for the brain, heart, stomach, kidneys, liver, pancreas, spleen, gallbladder, lungs, urinary bladder, and intestines. ROIs were applied to dynamic images to generate time-activity curves (TACs). Decay correction was removed from TACs, and the area under the curve (AUC) for each ROI was calculated. AUCs were then normalized by injected activity and organ volumes to produce radioligand residence times for each organ. These times were then used as input into the OLINDA/EXM 1.0 software to determine the total radiation dose in each organ and the effective dose for these OLINDA models: 55-kg female, 70-kg male, and 15-year-old adolescent.
Results
Visual evaluation detected high uptake in the liver, brain, gallbladder, gastrointestinal tract, and urinary bladder. The dose-limiting organ was the urinary bladder for adult males (0.0224 mSv/MBq) and liver for adult females (0.0248 mSv/MBq) with single-study dose limits of 2239 MBq and 2017 MBq
11
C-UCB-J, respectively. For adolescents, the large intestine was the dose-limiting organ (0.0266 mSv/MBq) with a single-study dose limit of 188 MBq.
Conclusions
11
C-UCB-J dosimetry in adults is consistent with those for many carbon-11-labeled ligands. Overall,
11
C-UCB-J can be used safely in adolescents, as in adults, to measure synaptic density in various neuropsychiatric and other relevant disorders.
General obesity, as reflected by BMI, is an established risk factor for esophageal adenocarcinoma (EAC), a suspected risk factor for gastric cardia adenocarcinoma (GCC) and appears unrelated to ...gastric non‐cardia adenocarcinoma (GNCC). How abdominal obesity, as commonly measured by waist circumference (WC), relates to these cancers remains largely unexplored. Using measured anthropometric data from 391,456 individuals from the European Prospective Investigation into Cancer and Nutrition (EPIC) study and 11 years of follow‐up, we comprehensively assessed the association of anthropometric measures with risk of EAC, GCC and GNCC using multivariable proportional hazards regression. One hundred twenty‐four incident EAC, 193 GCC and 224 GNCC were accrued. After mutual adjustment, BMI was unrelated to EAC, while WC showed a strong positive association (highest vs. lowest quintile HR = 1.19; 95% CI, 0.63–2.22 and HR = 3.76; 1.72–8.22, respectively). Hip circumference (HC) was inversely related to EAC after controlling for WC, while WC remained positively associated (HR = 0.35; 0.18–0.68, and HR=4.10; 1.94‐8.63, respectively). BMI was not associated with GCC or GNCC. WC was related to higher risks of GCC after adjustment for BMI and more strongly after adjustment for HC (highest vs. lowest quintile HR = 1.91; 1.09–3.37, and HR = 2.23; 1.28–3.90, respectively). Our study demonstrates that abdominal, rather than general, obesity is an indisputable risk factor for EAC and also provides evidence for a protective effect of gluteofemoral (subcutaneous) adipose tissue in EAC. Our study further shows that general obesity is not a risk factor for GCC and GNCC, while the role of abdominal obesity in GCC needs further investigation.
What's new?
While mainly general obesity, as measured by body mass index, has been investigated in relation to gastric and esophageal cancer, the effect of a large waist on these cancer sites is unknown. In this article, the authors report results of extensive analysis of measured anthropometry, including measures of general (BMI) and abdominal obesity (waist circumference), collected by the European Prospective Investigation into Cancer and Nutrition (EPIC). They show that general obesity is not a risk factor for esophageal and gastric cancer, while waist circumference strongly increases risk of esophageal cancer and may potentially be related to gastric cardia cancer.
ABSTRACT
The Square Kilometre Array (SKA) is the largest radio interferometer under construction in the world. The high accuracy, wide-field, and large size imaging significantly challenge the ...construction of the Science Data Processor (SDP) of SKA. We propose a hybrid imaging method based on improved W-Stacking and snapshots. The w-range is reduced by fitting the snapshot uv plane, thus effectively enhancing the performance of the improved W-Stacking algorithm. We present a detailed implementation of WS-Snapshot. With full-scale SKA1-LOW simulations, we present the imaging performance and imaging quality results for different parameter cases. The results show that the WS-Snapshot method enables more efficient distributed processing and significantly reduces the computational time overhead within an acceptable accuracy range, which would be crucial for subsequent SKA science studies.
In the boreal spring of 2014, the oceanic and atmospheric conditions were favorable for an El Niño's development. It was predicted that in 2014, a super El Niño or at least a regular El Niño with ...normal magnitude, would initiate. However, the growth rate of the sea surface temperature anomaly (SSTA) in the equatorial eastern Pacific suddenly declined in the boreal summer. The physical processes responsible for the termination of the 2014 El Niño were addressed in this study. We hypothesized that a meridional dipole of SSTA, characterized by a pronounced warm SSTA over the eastern North Pacific (ENP) and cold SSTA over the eastern South Pacific (ESP), played a crucial role in blocking the 2014 El Niño’s development. The observational analysis revealed that the meridional dipole of SSTA and the relevant anomalous cross-equatorial flow in the tropical eastern Pacific, induced anomalous westward (
u
′
<
0
) and upwelling (
w
′
>
0
) currents in the equatorial eastern Pacific, leading to negative anomalous zonal advection term (
-
u
′
∂
T
¯
/
∂
x
<
0
) and anomalous upwelling advection term (
-
w
′
∂
T
¯
/
∂
z
<
0
). Additionally, the anomalous cross-equatorial flow also induced northward meridional current anomalies that transported subtropical cold water to the equator. All the changes of the oceanic dynamic terms collectively caused negative SSTA tendency in the boreal summer, and thus killed off the budding 2014 El Niño. The idealized numerical experiments further confirmed that the 2014 El Niño’s development could be suppressed by the meridional dipole of SSTA, and both the ENP pole and ESP pole make a contribution.
Erratum: Towards a muon collider Adams, Dean; Andreetto, Paolo; Apresyan, Artur ...
The European physical journal. C, Particles and fields,
15/1, Letnik:
84, Številka:
1
Journal Article
The transcription factor and tumour suppressor p53 and its two homologues p63 and p73 form a family of proteins. p63 and p73 show much greater molecular complexity than p53 because they are expressed ...both as multiple alternatively spliced C-terminal isoforms, and as N-terminally deleted, dominant-negative proteins that show reciprocal functional regulation. In addition, several other factors, such as post-translational modifications and specific and common family regulatory proteins, result overall in subtle modulation of their biological effects. Although all p53, p63 and p73 family members are regulators of the cell cycle and apoptosis, the developmental abnormalities of p73- and p63-null mice do not show enhanced tumour susceptibility of p53 knockouts, suggesting that complex regulatory processes modulate the functional effects of this family of proteins.
Portability and low-cost analytic ability are desirable for point-of-care (POC) diagnostics; however, current POC testing platforms often require time-consuming multiple microfabrication steps and ...rely on bulky and costly equipment. This hinders the capability of microfluidics to prove its power outside of laboratories and narrows the range of applications. This paper details a self-contained microfluidic device, which does not require any external connection or tubing to deliver insert-and-use image-based analysis. Without any microfabrication, magnetorheological elastomer (MRE) microactuators including pumps, mixers and valves are integrated into one modular microfluidic chip based on novel manipulation principles. By inserting the chip into the driving and controlling platform, the system demonstrates sample preparation and sequential pumping processes. Furthermore, due to the straightforward fabrication process, chips can be rapidly reconfigured at a low cost, which validates the robustness and versatility of an MRE-enabled microfluidic platform as an option for developing an integrated lab-on-a-chip system.
Head motion correction (MC) is an essential process in brain positron emission tomography (PET) imaging. We have used the Polaris Vicra, an optical hardware-based motion tracking (HMT) device, for ...PET head MC. However, this requires attachment of a marker to the subject's head. Markerless HMT (MLMT) methods are more convenient for clinical translation than HMT with external markers. In this study, we validated the United Imaging Healthcare motion tracking (UMT) MLMT system using phantom and human point source studies, and tested its effectiveness on eight
F-FPEB and four
C-LSN3172176 human studies, with frame-based region of interest (ROI) analysis. We also proposed an evaluation metric, registration quality (
), and compared it to a data-driven evaluation method, motion-corrected centroid-of-distribution (MCCOD).
UMT utilized a stereovision camera with infrared structured light to capture the subject's real-time 3D facial surface. Each point cloud, acquired at up to 30 Hz, was registered to the reference cloud using a rigid-body iterative closest point registration algorithm.
In the phantom point source study, UMT exhibited superior reconstruction results than the Vicra with higher spatial resolution (0.35 ± 0.27 mm) and smaller residual displacements (0.12 ± 0.10 mm). In the human point source study, UMT achieved comparable performance as Vicra on spatial resolution with lower noise. Moreover, UMT achieved comparable ROI values as Vicra for all the human studies, with negligible mean standard uptake value differences, while no MC results showed significant negative bias. The
evaluation metric demonstrated the effectiveness of UMT and yielded comparable results to MCCOD.
We performed an initial validation of a commercial MLMT system against the Vicra. Generally, UMT achieved comparable motion-tracking results in all studies and the effectiveness of UMT-based MC was demonstrated.