Background There is limited information on the long-term outcomes and prognostic clinical predictors after edge-to-edge transcatheter mitral valve repair with the MitraClip system. Methods ...Consecutive patients with mitral regurgitation (MR) undergoing MitraClip therapy between October 2008 and November 2013 in 4 Italian centers were analyzed. The primary end point of interest was all-cause death. The secondary end point was the composite of all-cause death or rehospitalization for heart failure. Results A total of 304 patients were included, of which 79% had functional MR and 17% were in New York Heart Association functional class IV. Acute procedural success was obtained in 92% of cases, with no intraprocedural death. The cumulative incidences of all-cause death were 3.4%, 10.8%, and 18.6% at 30 days, 1 year, and 2 years, respectively. The corresponding incidences of the secondary end point were 4.4%, 22.0%, and 39.7%, respectively. In the Cox multivariate model, New York Heart Association functional class IV at baseline and ischemic MR etiology were found to significantly and independently predict both the primary and the secondary end point. A baseline, left ventricular end-systolic volume >110 mL was found to be an independent predictor of the secondary endpoint. Acute procedural success was independently associated with a lower risk of all-cause death and the combination of all-cause death or rehospitalization for heart failure at long-term follow-up. Conclusions In a cohort of patients undergoing MitraClip therapy, those presenting at baseline with ischemic functional etiology, severely dilated ventricles, or advanced heart failure and those undergoing unsuccessful procedures carried the worst prognosis.
Coronary bifurcation lesion (CBL) is a common but challenging scenario in percutaneous coronary interventions. Drug-coated balloons (DCBs) are modern devices with attractive perspective in CBL ...treatment. In-stent restenosis, small vessel and diffuse de-novo coronary artery disease have been, so far, considered the ideal scenario for DCBs application. Studies assessing DCBs in de-novo CBL demonstrated the safety and efficacy of this strategy. However, the heterogeneity of the study populations and the presence of methodological limitations prevent from drawing definite recommendations. Considering that the best treatment of bifurcations has not yet been defined, the "leaving nothing behind" philosophy will be the topic of future studies.
Objectives
Aim of this study is to evaluate safety, feasibility, and mid‐term outcome of transcatheter aortic valve implantation (TAVI) in cardiogenic shock (CS).
Background
Balloon aortic ...valvuloplasty in patients with severe aortic valve stenosis (SAS) complicated by CS is indicated but associated with a grim prognosis. TAVI might be a more reasonable treatment option in this setting but data are scant.
Methods
From March 2008 to February 2019, 51 patients with severe aortic valvulopathy (native SAS or degenerated aortic bioprosthesis) and CS treated by TAVI in 11 European centers were included in this multicenter registry. Demographic, clinical, and procedural data were collected, as well as clinical and echocardiographic follow‐up.
Results
The mean age of our study population was 75.8 ± 13, 49% were women, and mean Society of Thoracic Surgeons (STS) score was 19 ± 15%. Device success was achieved in 94.1%, with a 5% incidence of moderate/severe paravalvular leak. The 30‐day events were mortality 11.8%, stroke 2.0%, vascular complications 5.9%, and acute kidney injury 34%. Valve Academic Research Consortium‐2 early safety endpoint was reached in 35.3% of cases. At 1‐year of follow‐up, the mortality rate was 25.7% and the readmission for congestive heart failure was 8.6%.
Conclusions
TAVI seems to be a therapeutic option for patients with CS and SAS or degenerated aortic bioprosthesis in terms of both safety and efficacy at early and long‐term follow‐up.
Aortic valve-in-valve (ViV) procedure is a valid treatment option for patients affected by bioprosthetic heart valve (BHV) degeneration. However, ViV implantation is technically more challenging ...compared to native trans-catheter aortic valve replacement (TAVR). A deep knowledge of the mechanism and features of the failed BHV is pivotal to plan an adequate procedure. Multimodal imaging is fundamental in the diagnostic and pre-procedural phases. The main challenges associated with ViV TAVR consist of a higher risk of coronary obstruction, severe post-procedural patient-prosthesis mismatch, and a difficult coronary re-access. In this review, we describe the principles of ViV TAVR.
The aim of this study was to explore the adaptability of 3 contemporary surgical scores (Logistic EuroSCORE LES, EuroSCORE II ESII, and Society of Thoracic Surgeons Predicted Risk of Mortality ...STS-PROM) for prediction of mortality after percutaneous mitral valve repair with the MitraClip system. A total of 304 patients from the multicenter Getting Reduction of mitrAl inSufficiency by Percutaneous clip implantation in ITaly registry (GRASP-IT) were stratified based on LES, ESII, and STS-PROM tertiles and analyzed by different measurements of discrimination, calibration, and global accuracy with focus on 30-day and 1-, 2-, and 3-year mortality. A statistically significant gradient in the distribution of mortality was observed at all time points with ESII, at 2 years with LES, and at 2 and 3 years with STS-PROM. ESII had the best discrimination at 30 days (C-statistic 0.80), which remained acceptable at later follow-up, being significantly superior to that of LES at each time point (p = 0.003 at 30 days, p = 0.005 at 1 year, p = 0.011 at 2 years, and p = 0.029 at 3 years). Compared with STS-PROM, ESII showed better discrimination at 30 days (C-statistic 0.80 vs 0.62, p = 0.023). All scores overpredicted the risk of mortality at 30 days and were miscalibrated at 2 and 3 years. At 1 year, there was a good agreement between the observed and predicted probabilities for ESII and STS-PROM, whereas LES remained overpredictive. ESII showed the best global accuracy at 30 days and 1 year, whereas no notable differences were noted versus LES and STS-PROM at 2 and 3 years. In conclusion, lacking specific tools for risk stratification of patients undergoing MitraClip implantation, ESII holds favorable prognostic characteristics, which makes it a valid surrogate.
Introduction Recent studies have shown gender differences in cardiovascular outcomes after left atrial appendage closure (LAAC), highlighting different complication rates and adverse events, ...particularly in short-term assessments. As a result, there remains a significant knowledge gap on how these differences directly impact the efficacy and safety of LAAC procedures. The aim of this retrospective study was to investigate the clinical outcomes of LAAC in women and men using the Watchman FLX device. Methods This retrospective, multicenter study analyzes gender-specific outcomes in 650 patients who underwent LAAC with the Watchman FLX device between March 2019 and May 2022, drawn from the ITALIAN-FLX registry. Results The results show comparable rates of all-cause mortality, stroke, transient ischemic attack and major bleeding in men and women 12 months after the procedure. Notably, no significant gender differences were found for periprocedural complications. Conclusion In conclusion, this study shows that LAAC with the Watchman FLX device has comparable clinical outcomes between genders at both short-term and long-term follow-up.
Abstract Objectives The aim of this study was to assess the incidence and clinical impact of balloon post-dilation (BPD) after transcatheter aortic valve replacement (TAVR) with the CoreValve ...prosthesis (Medtronic Inc., Minneapolis, Minnesota). Background BPD is a widely adopted strategy to reduce the degree of paraprosthetic regurgitation in case of transcatheter heart valve underexpansion. However, controversies still remain regarding its real effectiveness and safety. Methods The ClinicalService (a nation-based data repository and medical care project) dataset was analyzed. All patients were dichotomized according to the need for BPD during the index procedure. Results Among 1,376 patients, BPD of the transcatheter heart valve was performed in 272 (19.8%). In 37% of cases, it was unsuccessful at reducing the paravalvular regurgitation to mild or less. No case of valve embolization, new intravalvular regurgitation, coronary occlusion, and aortic root injury occurred during BPD. There were no statistically significant differences between the 2 groups in the incidence of in-hospital all-cause and cardiovascular mortality, neurological events, myocardial infarction, bleeding, conversion to open-chest surgery, and the need for a permanent pacemaker. The need for BPD did not emerge as an independent risk factor for all-cause (adjusted hazard ratio HR: 1.33, 95% confidence interval CI: 0.81 to 2.19, p = 0.264) and cardiovascular (adjusted HR: 1.48, 95% CI: 0.74 to 2.97, p = 0.265) mortality at 1 year after the procedure. In addition, BPD did not predispose to higher odds of neurological events during 12 months after TAVR (HR: 0.92, 95% CI: 0.45 to 1.88, p = 0.815). Conclusions This large study showed that BPD after TAVR was safe and not associated with increased rates of cerebrovascular events, mortality, myocardial infarction, and aortic root injury.
Background: TAVR is a safe alternative to surgical aortic valve replacement (SAVR); however, sex-related differences are still debated. This research aimed to examine gender differences in a ...real-world transcatheter aortic valve replacement (TAVR) cohort. Methods: All-comer aortic stenosis (AS) patients undergoing TAVR with a Medtronic valve across 19 Italian sites were prospectively included in the Italian Clinical Service Project (NCT01007474) between 2007 and 2019. The primary endpoint was 1-year mortality. We also investigated 3-year mortality, and ischemic and hemorrhagic endpoints, and we performed a propensity score matching to assemble patients with similar baseline characteristics. Results: Out of 3821 patients, 2149 (56.2%) women were enrolled. Compared with men, women were older (83 ± 6 vs. 81 ± 6 years, p < 0.001), more likely to present severe renal impairment (GFR ≤ 30 mL/min, 26.3% vs. 16.3%, p < 0.001) but had less previous cardiovascular events (all p < 0.001), with a higher mean Society of Thoracic Surgeons (STS) score (7.8% ± 7.1% vs. 7.2 ± 7.5, p < 0.001) and a greater mean aortic gradient (52.4 ± 15.3 vs. 47.3 ± 12.8 mmHg, p < 0.001). Transfemoral TAVR was performed more frequently in women (87.2% vs. 82.1%, p < 0.001), with a higher rate of major vascular complications and life-threatening bleeding (3.9% vs. 2.4%, p = 0.012 and 2.5% vs. 1.4%, p = 0.024). One-year mortality differed between female and male (11.5% vs. 15.0%, p = 0.002), and this difference persisted after adjustment for significant confounding variables (Adj.HR1yr 1.47, 95%IC 1.18–1.82, p < 0.001). Three-year mortality was also significantly lower in women compared with men (19.8% vs. 24.9%, p < 0.001) even after adjustment for age, STS score, eGFR, diabetes and severe COPD (Adj.HR3yr 1.42, 95%IC 1.21–1.68, p < 0.001). These results were confirmed in 689 pairs after propensity score matching. Conclusion: Despite higher rates of peri-procedural complications, women presented better survival than men. This better adaptive response to TAVR may be driven by sex-specific factors.
Degeneration of a surgically implanted valve bioprosthesis may occur in elderly, frail patients with an extremely high risk to undergo redo cardiac surgery. Transapical or fully percutaneous ...transseptal approaches have been described in order to treat degenerated aortic and mitral bioprosthesis. We performed the first-in-man successful mitral transcatheter valve delivery with a valve-in-valve technique through an innovative route; ie, a video-assisted endoscopic direct access to the left atrium, in an 82-year-old patient who previously underwent surgical replacement of the mitral valve and with a prohibitive surgical risk.