The Fluorescence detector Array of Single-pixel Telescopes (FAST) is a design concept for a next-generation UHECR observatory, addressing the requirements for a large-area, low-cost detector suitable ...for measuring the properties of ultra-high energy cosmic rays (UHECRs), having energies exceeding 30 EeV, with an unprecedented aperture. We have developed a full-scale prototype consisting of four 200 mm diameter photo-multiplier tubes at the focus of a segmented mirror of 1.6 m in diameter. In October 2016, September 2017, and September 2018 we installed three such prototypes at the Black Rock Mesa site of the Telescope Array experiment in central Utah, USA. All three telescopes have been steadily taking data since installation. We report on the design and installation of these prototypes, and present some preliminary results, including measurements of artificial light sources, distant ultraviolet lasers, and UHECRs.
We present the construction of the optical part of the ToF (time-of-flight) subdetector prototype for the AFP (ATLAS Forward Proton) detector. The ToF detector in conjunction with a 3D silicon pixel ...tracker will tag and measure protons originating in central exclusive interactions p + p → p + X + p, where the two outgoing protons are scattered in the very forward directions. The ToF is required to reduce so-called pileup backgrounds that arise from multiple proton interactions in the same bunch crossing at high luminosity. The background can fake the signal of interest, and the extra rejection from the ToF allows the proton tagger to operate at the high luminosity required for measurement of the processes. The prototype detector uses fused silica bars emitting Cherenkov radiation as a relativistic particle passes through it. The emitted Cherenkov photons are detected by a micro-channel plate multi-anode Photomultiplier Tube (MCP-PMT) and processed by fast electronics.
In the present work we analyze sites in the Argentinian high Andes mountains as possible places for astrophysical/astronomical/solar observatories. They are located at: San Antonio de los Cobres ...(SAC) and El Leoncito/CASLEO region: sites 1 and 2. We consider the following atmospheric components that affect, in different and specific wavelength ranges, the detection of photons of astronomical/astrophysical/solar origin: ozone, microscopic particles, precipitable water and clouds. We also determined the atmospheric radiative transmittance in a day near the summer solstice at noon, in order to confirm the clearness of the sky in the proposed sites at SAC and El Leoncito. Consequently, all the collected and analyzed data in the present work, indicate that the proposed sites are very promising to host astrophysical/astronomical/solar observatories. Some atmospheric components, like aerosols, play a significant role in the attenuation of light (Cherencov and/or fluorescence) detected in cosmic rays (particles or gamma photons) astrophysical observatories, while others, like ozone have to be considered in astronomical/solar light detection.
We present a discovery and observation of an extraordinarily bright prompt optical emission of the GRB 060117 obtained by a wide-field camera atop the robotic telescope FRAM of the Pierre Auger ...Observatory from 2 to 10 min after the GRB. We found rapid average temporal flux decay of $\alpha = -1.7 \pm 0.1$ and a peak brightness $R = 10.1$ mag. Later observations by other instruments set a strong limit on the optical and radio transient fluxes, unveiling an unexpectedly rapid further decay. We present an interpretation featuring a relatively steep electron-distribution parameter $p \simeq 3.0$ and providing a straightforward solution for the overall fast decay of this optical transient as a transition between reverse and forward shock.
Total hip arthroplasty significantly improves the quality of life in majority of patients with osteoarthritis. However, prosthetic wear is a problem because of inducing the development of aseptic ...loosening and periprosthetic osteolysis which needs the revision surgery. Thus, the polyethylene wear measurement is the central to contemporary orthopaedics. Various in vivo methods have been developed offering the ability to determine and study the prosthetic cup linear wear before the revision surgery. The radiological methods are the most available but the accuracy and related relationship between measured linear wear and true value of volumetric wear is the problem. As the “golden” standard the in vitro methods can be employed. This contribution gives the review of previously published study concerned with the accuracy of three radiological techniques (Livermore, Charnley, and Dorr methods) based on the using the universal-type measuring microscope in vitro method. Moreover, this paper introduces the comparison of results obtained by the previously used microscope method and the newly developed optical scanning profilometry in vitro method. Results of the comparison shows the using of this optical method can specify and spread the mentioned study.
The contribution describes two optical and one contact measuring method used to measure the wear of polyethylene insert of knee implants. These implants are under stress in patient body and therefore ...they suffer from wear. The purpose of these measurements is the creation of sensor intended to measure a statistic file of damaged implants and compare this file with way of life and other parameters of patients, who used them.
ABSTRACT
A deep survey of the Large Magellanic Cloud at ∼0.1–100 TeV photon energies with the Cherenkov Telescope Array is planned. We assess the detection prospects based on a model for the emission ...of the galaxy, comprising the four known TeV emitters, mock populations of sources, and interstellar emission on galactic scales. We also assess the detectability of 30 Doradus and SN 1987A, and the constraints that can be derived on the nature of dark matter. The survey will allow for fine spectral studies of N 157B, N 132D, LMC P3, and 30 Doradus C, and half a dozen other sources should be revealed, mainly pulsar-powered objects. The remnant from SN 1987A could be detected if it produces cosmic-ray nuclei with a flat power-law spectrum at high energies, or with a steeper index 2.3–2.4 pending a flux increase by a factor of >3–4 over ∼2015–2035. Large-scale interstellar emission remains mostly out of reach of the survey if its >10 GeV spectrum has a soft photon index ∼2.7, but degree-scale 0.1–10 TeV pion-decay emission could be detected if the cosmic-ray spectrum hardens above >100 GeV. The 30 Doradus star-forming region is detectable if acceleration efficiency is on the order of 1−10 per cent of the mechanical luminosity and diffusion is suppressed by two orders of magnitude within <100 pc. Finally, the survey could probe the canonical velocity-averaged cross-section for self-annihilation of weakly interacting massive particles for cuspy Navarro–Frenk–White profiles.
We present a novel approach to the determination of the pointing of Imaging Atmospheric Cherenkov Telescopes (IACTs) using the trajectories of the stars in their camera’s field of view. The method ...starts with the reconstruction of the star positions from the Cherenkov camera data, taking into account the point spread function of the telescope, to achieve a satisfying reconstruction accuracy of the pointing position. A simultaneous fit of all reconstructed star trajectories is then performed with the orthogonal distance regression (ODR) method. ODR allows us to correctly include the star position uncertainties and use the time as an independent variable. Having the time as an independent variable in the fit makes it better suitable for various star trajectories. This method can be applied to any IACT and requires neither specific hardware nor interface or special data-taking mode. In this paper, we use the Large-Sized Telescope (LST) data to validate it as a useful tool to improve the determination of the pointing direction during regular data taking. The simulation studies show that the accuracy and precision of the method are comparable with the design requirements on the pointing accuracy of the LST (≤14″). With the typical LST event acquisition rate of 10 kHz, the method can achieve up to 50 Hz pointing monitoring rate, compared to ??(1) Hz achievable with standard techniques. The application of the method to the LST prototype (LST-1) commissioning data shows the stable pointing performance of the telescope.
The single-mirror small-size telescope (SST-1M) is one of the three proposed designs for the small-size telescopes (SSTs) of the Cherenkov Telescope Array (CTA) project. The SST-1M will be equipped ...with a 4 m-diameter segmented reflector dish and an innovative fully digital camera based on silicon photo-multipliers. Since the SST sub-array will consist of up to 70 telescopes, the challenge is not only to build telescopes with excellent performance, but also to design them so that their components can be commissioned, assembled and tested by industry. In this paper we review the basic steps that led to the design concepts for the SST-1M camera and the ongoing realization of the first prototype, with focus on the innovative solutions adopted for the photodetector plane and the readout and trigger parts of the camera. In addition, we report on results of laboratory measurements on real scale elements that validate the camera design and show that it is capable of matching the CTA requirements of operating up to high moonlight background conditions.