Xenon dual-phase time projection chambers designed to search for weakly interacting massive particles have so far shown a relative energy resolution which degrades with energy above
∼
200 keV due to ...the saturation effects. This has limited their sensitivity in the search for rare events like the neutrinoless double-beta decay of
136
Xe
at its
Q
value,
Q
β
β
≃
2.46
MeV
. For the XENON1T dual-phase time projection chamber, we demonstrate that the relative energy resolution at
1
σ
/
μ
is as low as (
0.80
±
0.02
) % in its one-ton fiducial mass, and for single-site interactions at
Q
β
β
. We also present a new signal correction method to rectify the saturation effects of the signal readout system, resulting in more accurate position reconstruction and indirectly improving the energy resolution. The very good result achieved in XENON1T opens up new windows for the xenon dual-phase dark matter detectors to simultaneously search for other rare events.
Abstract
A novel online distillation technique was developed for the XENON1T dark matter experiment to reduce intrinsic background components more volatile than xenon, such as krypton or argon, while ...the detector was operating. The method is based on a continuous purification of the gaseous volume of the detector system using the XENON1T cryogenic distillation column. A krypton-in-xenon concentration of (360 ± 60) ppq was achieved. It is the lowest concentration measured in the fiducial volume of an operating dark matter detector to date. A model was developed and fitted to the data to describe the krypton evolution in the liquid and gas volumes of the detector system for several operation modes over the time span of 550 days, including the commissioning and science runs of XENON1T. The online distillation was also successfully applied to remove 37Ar after its injection for a low-energy calibration in XENON1T. This makes the usage of 37Ar as a regular calibration source possible in the future. The online distillation can be applied to next-generation liquid xenon time projection chamber experiments to remove krypton prior to, or during, any science run. The model developed here allows further optimization of the distillation strategy for future large-scale detectors.
We detail the sensitivity of the proposed liquid xenon DARWIN observatory to solar neutrinos via elastic electron scattering. We find that DARWIN will have the potential to measure the fluxes of five ...solar neutrino components:
pp
,
7
Be,
13
N,
15
O and
pep
. The precision of the
13
N,
15
O and
pep
components is hindered by the double-beta decay of
136
Xe and, thus, would benefit from a depleted target. A high-statistics observation of
pp
neutrinos would allow us to infer the values of the electroweak mixing angle,
sin
2
θ
w
, and the electron-type neutrino survival probability,
P
ee
, in the electron recoil energy region from a few keV up to 200 keV for the first time, with relative precision of 5% and 4%, respectively, with 10 live years of data and a 30 tonne fiducial volume. An observation of
pp
and
7
Be neutrinos would constrain the neutrino-inferred solar luminosity down to 0.2%. A combination of all flux measurements would distinguish between the high- (GS98) and low-metallicity (AGS09) solar models with 2.1–2.5
σ
significance, independent of external measurements from other experiments or a measurement of
8
B neutrinos through coherent elastic neutrino-nucleus scattering in DARWIN. Finally, we demonstrate that with a depleted target DARWIN may be sensitive to the neutrino capture process of
131
Xe.
A difficult task with many particle detectors focusing on interactions below approximately 100 keV is to perform a calibration in the appropriate energy range that adequately probes all regions of ...the detector. Because detector response can vary greatly in various locations within the device, a spatially uniform calibration is important. We present a new method for calibration of liquid xenon (LXe) detectors, using the short-lived (83m)Kr. This source has transitions at 9.4 and 32.1 keV, and as a noble gas like Xe, it disperses uniformly in all regions of the detector. Even for low source activities, the existence of the two transitions provides a method of identifying the decays that is free of background. We find that at decreasing energies, the LXe light yield increases, while the amount of electric field quenching is diminished. Additionally, we show that if any long-lived radioactive backgrounds are introduced by this method, they will present less than 67x10(-6) events kg(-1) day(-1) keV(-1) in the next generation of LXe dark matter direct detection searches.
Laboratory experiments searching for galactic dark matter particles scattering off nuclei have so far not been able to establish a discovery. We use data from the XENON100 experiment to search for ...dark matter interacting with electrons. With no evidence for a signal above the low background of our experiment, we exclude a variety of representative dark matter models that would induce electronic recoils. For axial-vector couplings to electrons, we exclude cross sections above 6 × 10–35 cm2 for particle masses of mx = 2 GeV/c2. Independent of the dark matter halo, we exclude leptophilic models as an explanation for the long-standing DAMA/LIBRA signal, such as couplings to electrons through axial-vector interactions at a 4.4σ. confidence level, mirror dark matter at 3.6σ, and luminous dark matter at 4.6σ.
The DARWIN observatory is a proposed next-generation experiment to search for particle dark matter and for the neutrinoless double beta decay of
136
Xe. Out of its 50 t total natural xenon inventory, ...40 t will be the active target of a time projection chamber which thus contains about 3.6 t of
136
Xe. Here, we show that its projected half-life sensitivity is
2.4
×
10
27
year
, using a fiducial volume of 5 t of natural xenon and 10 year of operation with a background rate of less than 0.2 events/(t
·
year) in the energy region of interest. This sensitivity is based on a detailed Monte Carlo simulation study of the background and event topologies in the large, homogeneous target. DARWIN will be comparable in its science reach to dedicated double beta decay experiments using xenon enriched in
136
Xe.