Prognosis of Chronic Chagasic Cardiomyopathy (CCC) patients depends on functional and clinical factors. Bradyarrhythmia requiring pacemaker is a common complication. Prognosis of these patients is ...poorly studied, and mortality risk factors are unknown. We aimed to identify predictors of death and to define a risk score for mortality in a large cohort of CCC patients with pacemaker.
It was an observational, unicentric and prospective study. The endpoint was all-cause mortality. Cox regression was used to identify predictors of death and to define a risk score. Bootstrapping method was used to internal score validation.
We included 555 patients and after a mean follow-up of 3.7±1.5 years, 100 (18%) deaths occurred. Predictors of death were: right ventricular dysfunction (HR hazard ratio 2.24; 95%CI 1.41-3.53; P = 0.001); heart failure class III or IV (HR 2.16; 95% confidence interval 95%CI 1.16-4.00; P = 0.014); renal disease (HR 2.14; 95%CI 1.24-3.68; P = 0.006); left ventricular end-systolic diameter > 44mm (HR 1.97; 95%CI 1.26-3.05; P = 0.003); atrial fibrillation (HR 1.94; 95%CI 1.25-2.99; P = 0.003) and cardiomegaly on X-ray (HR 1.87; 95%CI 1.10-3.17; P = 0.020). The score identified patients with: low (0-20 points), intermediate (21-30 points) and high risk (>31points). The optimism-corrected C-statistic of the predictive model was 0.751 (95% CI 0.696-0.806). Internal validation with bootstrapping revealed a calibration slope of 0.946 (95% CI 0.920-0.961), reflecting a small degree of over-optimism and C-statistic of 0.746 (95% CI 0.692-0.785).
This study identified predictors of mortality in CCC patients with pacemaker defining a simple, validated and specific risk score.
BACKGROUNDThe use of artificial cardiac pacemakers has grown steadily in line with the aging population.OBJECTIVESTo determine the rates of hospital readmissions and complications after pacemaker ...implantation or pulse generator replacement and to assess the impact of these events on annual treatment costs from the perspective of the Unified Health System (SUS).METHODSA prospective registry, with data derived from clinical practice, collected during index hospitalization and during the first 12 months after the surgical procedure. The cost of index hospitalization, the procedure, and clinical follow-up were estimated according to the values reimbursed by SUS and analyzed at the patient level. Generalized linear models were used to study factors associated with the total annual treatment cost, adopting a significance level of 5%.RESULTSA total of 1,223 consecutive patients underwent initial implantation (n=634) or pulse generator replacement (n=589). Seventy episodes of complication were observed in 63 patients (5.1%). The incidence of hospital readmissions within one year was 16.4% (95% CI 13.7% - 19.6%) after initial implants and 10.6% (95% CI 8.3% - 13.4%) after generator replacements. Chronic kidney disease, history of stroke, length of hospital stays, need for postoperative intensive care, complications, and hospital readmissions showed a significant impact on the total annual treatment cost.CONCLUSIONSThe results confirm the influence of age, comorbidities, postoperative complications, and hospital readmissions as factors associated with increased total annual treatment cost for patients with pacemakers.
Noncommunicable diseases (NCDs), also known as chronic diseases that are long-lasting, are considered the major cause of death and disability worldwide, and the six pillars of lifestyle medicine ...(nutrition, exercise, toxic control, stress management, restorative sleep, and social connection) play an important role in a holistic management of their prevention and treatment. In addition, medical guidelines are the most accepted documents with recommendations to manage NCDs.
The present study aims to analyze the lack of lifestyle pillars concerning the major Brazilian medical guidelines for NCDs and identify evidence in the literature that could justify their inclusion in the documents.
Brazilian guidelines were selected according to the most relevant causes of death in Brazil, given by the Mortality Information System, published by the Brazilian Ministry of Health in 2019. Journals were screened in the PUBMED library according to the disease and non-mentioned pillars of lifestyle.
Relevant causes of deaths in Brazil are acute myocardial infarction (AMI), diabetes mellitus (DM), and chronic obstructive pulmonary diseases (COPD). Six guidelines related to these NCDs were identified, and all address aspects of lifestyle, but only one, regarding cardiovascular prevention, highlights all six pillars. Despite this, a literature search involving over 50 articles showed that there is evidence that all the pillars can help control each of these NCDs.
Rarely are the six pillars of lifestyle contemplated in Brazilian guidelines for AMI, DM, and COPD. The literature review identified evidence of all lifestyle pillars to offer a holistic approach for the management and prevention of NCDs.
Venous obstructions are common in patients with transvenous cardiac implantable electronic devices, but they rarely cause immediate clinical problems. The main consequence of these lesions is the ...difficulty in obtaining venous access for additional leads implantation.
We aimed to assess the prevalence and predictor factors of venous lesions in patients referred to lead reoperations, and to define the role of preoperative venography in the planning of these procedures.
From April 2013 to July 2016, contrast venography was performed in 100 patients referred to device upgrade, revision and lead extraction. Venous lesions were classified as non-significant (< 50%), moderate stenosis (51-70%), severe stenosis (71-99%) or occlusion (100%). Collateral circulation was classified as absent, discrete, moderate or accentuated. The surgical strategy was defined according to the result of the preoperative venography. Univariate analysis was used to investigate predictor factors related to the occurrence of these lesions, with 5% of significance level.
Moderate venous stenosis was observed in 23%, severe in 13% and occlusions in 11%. There were no significant differences in relation to the device side or the venous segment. The usefulness of the preoperative venography to define the operative tactic was proven, and in 99% of the cases, the established surgical strategy could be performed according to plan.
The prevalence of venous obstruction is high in CIED recipients referred to reoperations. Venography is highly indicated as a preoperative examination for allowing the adequate surgical planning of procedures involving previous transvenous leads.
Complications after surgical procedures in patients with cardiac implantable electronic devices (CIED) are an emerging problem due to an increasing number of such procedures and aging of the ...population, which consequently increases the frequency of comorbidities.
To identify the rates of postoperative complications, mortality, and hospital readmissions, and evaluate the risk factors for the occurrence of these events.
Prospective and unicentric study that included all individuals undergoing CIED surgical procedures from February to August 2011. The patients were distributed by type of procedure into the following groups: initial implantations (cohort 1), generator exchange (cohort 2), and lead-related procedures (cohort 3). The outcomes were evaluated by an independent committee. Univariate and multivariate analyses assessed the risk factors, and the Kaplan-Meier method was used for survival analysis.
A total of 713 patients were included in the study and distributed as follows: 333 in cohort 1, 304 in cohort 2, and 76 in cohort 3. Postoperative complications were detected in 7.5%, 1.6%, and 11.8% of the patients in cohorts 1, 2, and 3, respectively (p = 0.014). During a 6-month follow-up, there were 58 (8.1%) deaths and 75 (10.5%) hospital readmissions. Predictors of hospital readmission included the use of implantable cardioverter-defibrillators (odds ratio OR = 4.2), functional class III--IV (OR = 1.8), and warfarin administration (OR = 1.9). Predictors of mortality included age over 80 years (OR = 2.4), ventricular dysfunction (OR = 2.2), functional class III-IV (OR = 3.3), and warfarin administration (OR = 2.3).
Postoperative complications, hospital readmissions, and deaths occurred frequently and were strongly related to the type of procedure performed, type of CIED, and severity of the patient's underlying heart disease.
Complicações após procedimentos cirúrgicos em portadores de dispositivos cardíacos eletrônicos implantáveis (DCEI) são um problema emergente devido ao aumento crescente na taxa destes procedimentos e ao envelhecimento da população, com consequente aumento de comorbidades.
Identificar as taxas de complicações pós-operatórias, mortalidade e readmissão hospitalar, e pesquisar fatores de risco para a ocorrência desses eventos.
Registro prospectivo e unicêntrico que incluiu todos os indivíduos submetidos a procedimentos cirúrgicos em DCEI no período de fevereiro a agosto de 2011. Os pacientes foram distribuídos por tipos de procedimento nos seguintes grupos: implantes iniciais (coorte 1), troca de gerador (coorte 2) e procedimentos em cabos-eletrodos (coorte 3). Os desfechos foram avaliados por um comitê independente. Empregou-se a análise univariada e multivariada para a pesquisa de fatores de risco e o método de Kaplan-Meier para análise de sobrevida.
Foram incluídos 713 pacientes, sendo 333, 304 e 76 distribuídos nas coortes 1, 2 e 3, respectivamente. Complicações pós-operatórias foram detectadas em 7,5%, 1,6% e 11,8% dos pacientes nas coortes 1, 2 e 3, respectivamente (p = 0,014). Durante os 6 meses de seguimento, houve 58 (8,1%) óbitos e 75 (10,5%) readmissões hospitalares. Preditores de readmissão hospitalar incluíram o uso de cardioversor-desfibrilador implantável ( odds ratio OR = 4,2), classe funcional III-IV (OR = 1,8) e uso de warfarina (OR = 1,9). Preditores de mortalidade incluíram idade acima de 80 anos (OR = 2,4), disfunção ventricular (OR = 2,2), classe funcional III-IV (OR = 3,3) e uso de warfarina (OR = 2,3).
Complicações pós-operatórias, readmissões hospitalares e óbitos foram frequentes. Esses eventos estiveram fortemente relacionados ao tipo de procedimento realizado, tipo de DCEI e gravidade da doença cardíaca do paciente.
Abstract Background Myocardial fibrosis (MF) occurs in up to 80% of subjects with asymptomatic or mildly symptomatic hypertrophic cardiomyopathy (HCM) and can constitute an arrhythmogenic substrate ...for re-entrant, life-threatening ventricular arrhythmias in predisposed persons. Objective The aim was to investigate whether MF detected by delayed enhancement cardiac CT is predictive of ventricular tachycardia (VT) and fibrillation (VF) that require appropriate therapy by an implantable cardioverter defibrillator (ICD) in patients with HCM. Methods Twenty-six patients with HCM with previously (for at least 1 year) implanted ICD underwent MF evaluation by cardiac CT. MF was quantified by myocardial delayed enhanced cardiac CT. Data on ICD firing were recorded every 3 months after ICD implantation. Risk factors for sudden cardiac death in patients with HCM were evaluated in all patients. Results MF was present in 25 of 26 patients (96%) with mean fibrosis mass of 20.5 ± 15.8 g. Patients with appropriate ICD shocks for VF/VT had significantly greater MF mass than patients without (29.10 ± 19.13 g vs 13.57 ± 8.31 g; P = .01). For a MF mass of at least 18 g, sensitivity and specificity for appropriate ICD firing were 73% (95% CI, 49%–88%) and 71% (95% CI, 56%–81%), respectively. Kaplan–Meier curves indicated a significantly greater VF/VT event rate in patients with MF mass ≥18 g than in patients with MF <18 g ( P = .02). In the Cox regression analysis, the amount of MF was independently associated with VF/VT in ICD-stored electrograms. Conclusion The mass of MF detected by cardiac CT in patients with HCM at high risk of sudden death was associated with appropriate ICD firings.
Aims
Although cardiac resynchronization therapy (CRT) improves functional capacity in heart failure patients, a blunted heart rate (HR) response remains after treatment. So we aimed to evaluate the ...feasibility of the physiological pacing rate (PPR) in CRT patients.
Methods
A cohort of 30 clinical mildly symptomatic CRT patients underwent the six‐minute walk test (6MWT). During the 6MWT, HR, blood pressure, and maximum walking distance were assessed. The measurements were obtained in a pre to post manner, with CRT at nominal settings and with the physiological phase (CRT PPR), in which HR was increased by 10% above the maximum HR achieved previously. The CRT cohort also comprised a matched control group (CRT CG). In the CRT CG, the 6MWT was repeated after the standard evaluation with no PPR. The evaluations were blinded for patients and for the 6MWT evaluator.
Results
During the 6MWT, CRT PPR led to an increase in walking distance of 40.5 m (9.2%; P < 0.0001) when compared with baseline trial. Additionally, CRT PPR increased the maximum walking distance compared with CRT CG 479.3 ± 68.9 m vs. 420.3 ± 44.8 m, respectively, P = 0.001. In the CRT CG, CRT PPR increased the variation in walking distance, compared with baseline trials, respectively 2.40 ± 3.8% vs. 9.25 ± 7.0%, P = 0.007.
Conclusions
In mildly symptomatic CRT patients PPR is feasible, leading to improvements in functional capacity. In this regard, the efficacy of PPR must be confirmed by controlled randomized trials.
To perform a comprehensive evaluation of heart rhythm disorders and the influence of disease/therapy factors in a large systemic lupus erythematosus (SLE) cohort.
Three hundred and seventeen ...consecutive patients of an ongoing electronic database protocol were evaluated by resting electrocardiogram and 142 were randomly selected for 24 h Holter monitoring for arrhythmia and conduction disturbances. The mean age was 40.2 ± 12.1 years and disease duration was 11.4 ± 8.1 years. Chloroquine (CQ) therapy was identified in 69.7% with a mean use of 8.5 ± 6.7 years. Electrocardiogram abnormalities were detected in 66 patients (20.8%): prolonged QTc/QTd (14.2%); bundle-branch block (2.5%); and atrioventricular block (AVB) (1.6%). Age was associated with AVB (P = 0.029) and prolonged QTc/QTd (P = 0.039) whereas anti-Ro/SS-A and Systemic Lupus Erythematosus Disease Activity Index (SLEDAI) scores were not (P > 0.05). Chloroquine was negatively associated with AVB (P = 0.01) as was its longer use (6.1 ± 6.9 vs. 1.0 ± 2.5 years, P = 0.018). Time of CQ use was related with the absence of AVB odds ratio (OR) = 0.103; 95% confidence interval (CI) = 0.011-0.934, P = 0.043 in multiple logistic regression. Holter monitoring revealed abnormalities in 121 patients (85.2%): supraventricular ectopies (63.4%) and tachyarrhythmia (18.3%); ventricular ectopies (45.8%). Atrial tachycardia/fibrillation (AT/AF) were associated with shorter CQ duration (7.05 ± 7.99 vs. 3.63 ± 5.02 years, P = 0.043) with a trend to less CQ use (P = 0.054), and older age (P < 0.001). Predictors of AT/AF in multiple logistic regression were age (OR = 1.115; 95% CI = 1.059-1.174, P < 0.001) and anti-Ro/SS-A (OR = 0.172; 95% CI = 0.047-0.629, P = 0.008).
Chloroquine seems to play a protective role in the unexpected high rate of cardiac arrhythmias and conduction disturbances observed in SLE. Further studies are necessary to determine if this antiarrhythmic effect is due to the disease control or a direct effect of the drug.