To minimize neuromuscular electrical stimulation during electroporation-based treatments, the replacement of long monophasic pulses with bursts of biphasic high-frequency pulses in the range of ...microseconds was suggested in order to reduce muscle contraction and pain sensation due to pulse application. This treatment modality appeared under the term high-frequency electroporation (HF-EP), which can be potentially used for some clinical applications of electroporation such as electrochemotherapy, gene electrotransfer, and tissue ablation. In cardiac tissue ablation, which utilizes irreversible electroporation, the treatment is being established as Pulsed Field Ablation. While the reduction of muscle contractions was confirmed in multiple in vivo studies, the reduction of pain sensation in humans was not confirmed yet, nor was the relationship between muscle contraction and pain sensation investigated. This is the first study in humans examining pain sensation using biphasic high-frequency electroporation pulses. Twenty-five healthy individuals were subjected to electrical stimulation of the tibialis anterior muscle with biphasic high-frequency pulses in the range of few microseconds and both, symmetric and asymmetric interphase and interpulse delays. Our results confirm that biphasic high-frequency pulses with a pulse width of 1 or 2 µs reduce muscle contraction and pain sensation as opposed to currently used longer monophasic pulses. In addition, interphase and interpulse delays play a significant role in reducing the muscle contraction and/or pain sensation. The study shows that the range of the optimal pulse parameters may be increased depending on the prerequisites of the therapy. However, further evaluation of the biphasic pulse protocols presented herein is necessary to confirm the efficiency of the newly proposed HF-EP.
High-frequency bipolar electric pulses have been shown to mitigate undesirable muscle contraction during irreversible electroporation (IRE) therapy. Here, we evaluate the potential applicability of ...such pulses for introducing exogenous molecules into cells, such as in electrochemotherapy (ECT). For this purpose we develop a method for calculating the time course of the effective permeability of an electroporated cell membrane based on real-time imaging of propidium transport into single cells that allows a quantitative comparison between different pulsing schemes. We calculate the effective permeability for several pulsed electric field treatments including trains of 100μs monopolar pulses, conventionally used in IRE and ECT, and pulse trains containing bursts or evenly-spaced 1μs bipolar pulses. We show that shorter bipolar pulses induce lower effective membrane permeability than longer monopolar pulses with equivalent treatment times. This lower efficiency can be attributed to incomplete membrane charging. Nevertheless, bipolar pulses could be used for increasing the uptake of small molecules into cells more symmetrically, but at the expense of higher applied voltages. These data indicate that high-frequency bipolar bursts of electrical pulses may be designed to electroporate cells as effectively as and more homogeneously than conventional monopolar pulses.
Display omitted
•Real-time imaging and permeability analysis were performed post-electroporation treatment.•Rapid bipolar electrical pulses induce lower membrane permeability than longer monopolar pulses.•Transmembrane transfer of molecules may be achieved using trains of short pulse widths.•Rapid bipolar pulses need larger amplitudes to disrupt cells similar to longer monopolar pulses.
For this systematic review, 203 published reports on effects of electroporation using nanosecond high-voltage electric pulses (nsEP) on eukaryotic cells (human, animal, plant) in vitro were analyzed. ...A field synopsis summarizes current published data in the field with respect to publication year, cell types, exposure configuration, and pulse duration. Published data were analyzed for effects observed in eight main target areas (plasma membrane, intracellular, apoptosis, calcium level and distribution, survival, nucleus, mitochondria, stress) and an additional 107 detailed outcomes. We statistically analyzed effects of nsEP with respect to three pulse duration groups: A: 1–10ns, B: 11–100ns and C: 101–999ns. The analysis confirmed that the plasma membrane is more affected with longer pulses than with short pulses, seen best in uptake of dye molecules after applying single pulses. Additionally, we have reviewed measurements of nsEP and evaluations of the electric fields to which cells were exposed in these reports, and we provide recommendations for assessing nanosecond pulsed electric field effects in electroporation studies.
•We systematically reviewed effects of nanosecond electric pulses on cells in vitro.•Previously published data were statistically analyzed to consolidate the knowledge.•Plasma membrane is more affected with longer pulses than with short.•Descriptions of electric fields in electroporation studies should be more precise.
In gene electrotransfer and cardiac ablation with irreversible electroporation, treated muscle cells are typically of elongated shape and their orientation may vary. Orientation of cells in electric ...field has been reported to affect electroporation, and hence electrodes placement and pulse parameters choice in treatments for achieving homogeneous effect in tissue is important. We investigated how cell orientation influences electroporation with respect to different pulse durations (ns to ms range), both experimentally and numerically. Experimentally detected electroporation (evaluated separately for cells parallel and perpendicular to electric field) via Ca
uptake in H9c2 and AC16 cardiomyocytes was numerically modeled using the asymptotic pore equation. Results showed that cell orientation affects electroporation extent: using short, nanosecond pulses, cells perpendicular to electric field are significantly more electroporated than parallel (up to 100-times more pores formed), and with long, millisecond pulses, cells parallel to electric field are more electroporated than perpendicular (up to 1000-times more pores formed). In the range of a few microseconds, cells of both orientations were electroporated to the same extent. Using pulses of a few microseconds lends itself as a new possible strategy in achieving homogeneous electroporation in tissue with elongated cells of different orientation (e.g. electroporation-based cardiac ablation).
An increased permeability of a cell membrane during the application of high-voltage pulses results in increased transmembrane transport of molecules that otherwise cannot enter the cell. Increased ...permeability of a cell membrane is accompanied by increased membrane conductivity; thus, by measuring electric conductivity the extent of permeabilized tissue could be monitored in real time. In this article the effect of cell electroporation caused by high-voltage pulses on the conductivity of a cell suspension was studied by current-voltage measurements during and impedance measurement before and after the pulse application. At the same time the percentage of permeabilized and survived cells was determined and the extent of osmotic swelling measured. For a train of eight pulses a transient increase in conductivity of a cell suspension was obtained above permeabilization threshold in low- and high-conductive medium with complete relaxation in <1
s. Total conductivity changes and impedance measurements showed substantial changes in conductivity due to the ion efflux in low-conductive medium and colloid-osmotic swelling in both media. Our results show that by measuring electric conductivity during the pulses we can detect limit permeabilization threshold but not directly permeabilization level, whereas impedance measurements in seconds after the pulse application are not suitable.
The exact mechanisms of nucleic acid (NA) delivery with gene electrotransfer (GET) are still unknown, which represents a limitation for its broader use. Further, not knowing the effects that ...different experimental electrical and biological parameters have on GET additionally hinders GET optimization, resulting in the majority of research being performed using a trial-and-error approach. To explore the current state of knowledge, we conducted a systematic literature review of GET papers in in vitro conditions and performed meta-analyses of the reported GET efficiency. For now, there is no universal GET strategy that would be appropriate for all experimental aims. Apart from the availability of the required electroporation device and electrodes, the choice of an optimal GET approach depends on parameters such as the electroporation medium; type and origin of cells; and the size, concentration, promoter, and type of the NA to be transfected. Equally important are appropriate controls and the measurement or evaluation of the output pulses to allow a fair and unbiased evaluation of the experimental results. Since many experimental electrical and biological parameters can affect GET, it is important that all used parameters are adequately reported to enable the comparison of results, as well as potentially faster and more efficient experiment planning and optimization.
Electroporation is an emerging technology, with great potential in many different medical and biotechnological applications, food engineering and biomass processing. Large variations of biological ...load characteristics, however, represent a great challenge in electroporator design, which results in different solutions. Because a clinical electroporator is a medical device, it must comply with medical device regulative and standards. However, none of the existing standards directly address the operation or electroporator’s performance requirements. In order to evaluate clinical, laboratory and prototype electroporation devices during the development process, or to evaluate their final performance considering at least from the perspective of output pulse parameters, we present a case study on the design of an electronic emulator of biological tissue as an electrical load during electroporation. The proposed electronic load emulator is a proof of concept, which enables constant and sustainable testing and unbiased comparison of different electroporators’ operations. We developed an analog electrical circuit that has equivalent impedance to the beef liver tissue in combination with needle electrodes, during high voltage pulse delivery and/or electroporation. Current and voltage measurements during electroporation of beef liver tissue ex vivo, were analyzed and parametrized to define the analog circuit equation. An equivalent circuit was simulated, built and validated. The proposed concept of an electronic load emulator can be used for “classical” electroporator (i.e., not nanosecond) performance evaluation and comparison of their operation. Additionally, it facilitates standard implementation regarding the testing protocol and enables quality assurance.
Electroporation is used in medicine for drug and gene delivery, and as a nonthermal ablation method in tumor treatment and cardiac ablation. Electroporation involves delivering high-voltage electric ...pulses to target tissue; however, this can cause effects beyond the intended target tissue like nerve stimulation, muscle contractions and pain, requiring use of sedatives or anesthetics. It was previously shown that adjusting pulse parameters may mitigate some of these effects, but not how these adjustments would affect electroporation's efficacy. We investigated the effect of varying pulse parameters such as interphase and interpulse delay while keeping the duration and number of pulses constant on nerve stimulation, muscle contraction and assessing pain and electroporation efficacy, conducting experiments on human volunteers, tissue samples and cell lines in vitro. Our results show that using specific pulse parameters, particularly short high-frequency biphasic pulses with short interphase and long interpulse delays, reduces muscle contractions and pain sensations in healthy individuals. Higher stimulation thresholds were also observed in experiments on isolated swine phrenic nerves and human esophagus tissues. However, changes in the interphase and interpulse delays did not affect the cell permeability and survival, suggesting that modifying the pulse parameters could minimize adverse effects while preserving therapeutic goals in electroporation.
Gene electrotransfer (GET) is considered one of the most efficient, safe, reproducible, and cost-effective methods of gene therapy, in which a gene is delivered to the cells in the form of a plasmid ...DNA vector by a method known as electroporation. To achieve successful electroporation, cells must be exposed to sufficiently high electric fields generated by short-duration, high-voltage electrical pulses that result in a temporary increase in plasma membrane permeability. The electrical pulses are generated by pulse generators (electroporators) and delivered to the cells via electrodes (applicators). However, there is a lack of standardized pulse delivery protocols as well as certified clinical pulse generators and applicators for gene delivery. In this paper, the development of a new pulse generator, applicator, and pulse delivery protocol for GET to skin cells is presented. A numerical model of electroporated skin developed and tested for two electrode configurations and two different pulse delivery protocols is also presented. An alternative pulse delivery protocol was proposed. The developed pulse generator, applicator, and the proposed pulse delivery protocol were then used in vivo for GET to skin cells in mice. The results showed high efficiency of the proposed pulse delivery protocol for the purpose of GET in mouse skin cells. Specifically, electroporation with the developed pulse generator, applicator, and proposed pulse delivery protocol resulted in higher gene expression in skin cells compared to the currently used pulse generator, applicator, and pulse delivery protocol.
Equivalent Pulse Parameters for Electroporation Pucihar, Gorazd; Krmelj, Jasna; Reberšek, Matej ...
IEEE transactions on biomedical engineering,
11/2011, Letnik:
58, Številka:
11
Journal Article
Recenzirano
Odprti dostop
Electroporation-based applications require the use of specific pulse parameters for a successful outcome. When recommended values of pulse parameters cannot be set, similar outcomes can be obtained ...by using equivalent pulse parameters. We determined the relations between the amplitude and duration/number of pulses resulting in the same fraction of electroporated cells. Pulse duration was varied from 150 ns to 100 ms, and the number of pulses from 1 to 128. Fura 2-AM was used to determine electroporation of cells to Ca 2+ . With longer pulses or higher number of pulses, lower amplitudes are needed for the same fraction of electroporated cells. The expression derived from the model of electroporation could describe the measured data on the whole interval of pulse durations. In a narrower range (0.1-100 ms), less complex, logarithmic or power functions could be used instead. The relation between amplitude and number of pulses could best be described with a power function or an exponential function. We show that relatively simple two-parameter power or logarithmic functions are useful when equivalent pulse parameters for electroporation are sought. Such mathematical relations between pulse parameters can be important in planning of electroporation-based treatments, such as electrochemotherapy and nonthermal irreversible electroporation.