Back-support exoskeletons (BSEs) are wearable systems designed to reduce physical demands on the back, but which could have undesired effects beyond this design intention. Participants (n = 18) used ...two commercial BSEs to complete a brief (~15–20 s) simulated manual assembly task in varying conditions, with outcome measures that included: working posture, activity levels in “secondary” muscle groups (shoulders and thighs), perceived balance, discomfort, and usability. Using a BSE led to small and inconsistent changes in working postures (e.g., < ~14° change in lumbar flexion), muscular activity in the secondary muscle groups (<±2% of maximum voluntary isometric contractions), or perceived balance. Limitations in movement were reported for both BSEs, however, along with moderate levels of discomfort. Task-specific responses were evident for all outcome measures, though these depended on the specific BSE used and differed between genders in many cases. Future work should focus on interactions between a given user, BSE design, and task conditions.
•Undesired outcomes of two passive back-support exoskeletons (BSEs) were examined.•BSEs had task-specific effects on posture and discomfort during an assembly task.•Effects of a BSE often differed between task conditions, BSE designs, and genders.•BSE use had no major effects on activity levels in muscles other than the back.•Relatively large variations were found regarding usability of the BSEs.
The past two decades have been marked by three epidemics linked to emerging coronaviruses. The COVID-19 pandemic highlighted the existence of neurological manifestations associated with SARS-CoV-2 ...infection and raised the question of the neuropathogenicity of coronaviruses. The aim of this review was to summarize the current data about neurological manifestations and diseases linked to human coronaviruses.
Articles have been identified by searches of PubMed and Google scholar up to September 25, 2020, using a combination of coronavirus and neurology search terms and adding relevant references in the articles.
We found five cohorts providing prevalence data of neurological symptoms among a total of 2533 hospitalized COVID-19 patients, and articles focusing on COVID-19 patients with neurological manifestations including a total of 580 patients. Neurological symptoms involved up to 73% of COVID-19 hospitalized patients, and were mostly headache, myalgias and impaired consciousness. Central nervous system (CNS) manifestations reported in COVID-19 were mostly non-specific encephalopathies that represented between 13% and 40% of all neurological manifestations; post-infectious syndromes including acute demyelinating encephalomyelitis (ADEM, n=13), acute necrotizing encephalopathy (ANE, n=4), Bickerstaff's encephalitis (n=5), generalized myoclonus (n=3) and acute transverse myelitis (n=7); other encephalitis including limbic encephalitis (n=9) and miscellaneous encephalitis with variable radiologic findings (n=26); acute cerebrovascular diseases including ischemic strokes (between 1.3% and 4.7% of COVID-19 patients), hemorrhagic strokes (n=17), cerebral venous thrombosis (n=8) and posterior reversible encephalopathy (n=5). Peripheral nervous system (PNS) manifestations reported in COVID-19 were the following: Guillain–Barré syndrome (n=31) and variants including Miller Fisher syndrome (n=3), polyneuritis cranialis (n=2) and facial diplegia (n=2); isolated oculomotor neuropathy (n=6); critical illness myopathy (n=6). Neuropathological studies in COVID-19 patients demonstrated different patterns of CNS damage, mostly ischemic and hemorrhagic changes with few cases of inflammatory injuries. Only one case suggested SARS-CoV-2 infiltration in endothelial and neural cells. We found 10 case reports or case series describing 22 patients with neurological manifestations associated with other human coronaviruses. Among them we found four MERS patients with ADEM or Bickerstaff's encephalitis, two SARS patients with encephalitis who had a positive SARS-CoV PCR in cerebrospinal fluid, five patients with ischemic strokes associated with SARS, eight MERS patients with critical illness neuromyopathy and one MERS patient with Guillain–Barré Syndrome. An autopsy study on SARS-CoV patients demonstrated the presence of the virus in the brain of eight patients.
The wide range of neurological manifestations and diseases associated with SARS-CoV-2 is consistent with multiple pathogenic pathways including post-infectious mechanisms, septic-associated encephalopathies, coagulopathy or endothelitis. There was no definite evidence to support direct neuropathogenicity of SARS-CoV-2.
Exoskeleton (EXO) technologies are a promising ergonomic intervention to reduce the risk of work-related musculoskeletal disorders, with efficacy supported by laboratory- and field-based studies. ...However, there is a lack of field-based evidence on long-term effects of EXO use on physical demands.
A longitudinal, controlled research design was used to examine the effects of arm-support exoskeleton (ASE) use on perceived physical demands during overhead work at nine automotive manufacturing facilities. Data were collected at five milestones (baseline and at 1, 6, 12, and 18 months) using questionnaires. Linear mixed models were used to understand the effects of ASE use on perceived work intensity and musculoskeletal discomfort (MSD). Analyses were based on a total of 41 participants in the EXO group and 83 in a control group.
Across facilities, perceived work intensity and MSD scores did not differ significantly between the EXO and control groups. In some facilities, however, neck and shoulder MSD scores in the EXO group decreased over time. Wrist MSD scores in the EXO group in some facilities remained unchanged, while those scores increased in the control group over time. Upper arm and low back MSD scores were comparable between the experimental groups.
Longitudinal effects of ASE use on perceived physical demands were not found, though some suggestive results were evident. This lack of consistent findings is discussed, particularly supporting the need for systematic and evidence-based ASE implementation approaches in the field that can guide the optimal selection of a job for ASE use.
Overhead work is an important risk factor for upper extremity (UE) musculoskeletal disorders. We examined the potential of a mechanical arm and an exoskeletal vest as a wearable assistive device ...(WADE) for overhead work. Twelve participants completed 10 minutes of simulated, intermittent overhead work, using each of three payloads (1.1, 3.4 and 8.1 kg) and with/without the WADE. Ratings of perceived discomfort (RPDs) and electromyography (EMG) were obtained for the upper arms, shoulders and low back. Using the WADE, UE RPDs decreased by ∼50% with the heavier payloads, whereas smaller (∼25%) and non-significant increases in low-back RPDs were found and were relatively independent of payload. Changes in RPDs with WADE use were consistent with physical demands indicated by EMG, though EMG-based differences in fatigue were less apparent. Participants generally preferred using the WADE, particularly with heavier payloads. These results supported the potential utility of a WADE as an intervention for overhead work.
Practitioner Summary: A wearable assistive device for overhead work reduced physical demands on the upper extremity and had high acceptance, though some evidence suggested increased demands at the low back. While some design needs were found and field-testing is needed, this may be a useful practical intervention.
Load carriage is an inevitable daily task for soldiers. The purposes of this study were to explore the extent to which gait variability (GV) is affected by load carriage and experience among military ...cadets, and whether experience-related differences in GV are dependent on task demand. Two groups of cadets (30 experienced, 30 less experienced) completed a load carriage task in each of three load conditions (no load, 16 kg, 32 kg). Three categories of GV measures were obtained: spatiotemporal variability, joint kinematic variability, and Lyapunov exponents. Compared to traditional mean gait measures, GV measures were more discriminative of experience: although both groups showed similar mean gait measures, the experienced participants had reduced variability in spatiotemporal measures (p ≤ 0.008) and joint kinematics (p ≤ 0.004), as well as lower levels of long-term local dynamic stability at the ankle (p = 0.040). In both groups, heavier loads were also caused increased GV (p ≤ 0.018) and enhanced short-term local dynamic stability at the knee (p = 0.014). These results emphasize the importance of GV measures, which may provide a more complete description of adaptability, stability, and control; highlight alternate movement strategies during more difficult load carriage; and capture experience-related differences in load carriage strategies.
Continuous seated postures may increase the risk of adverse health outcomes such as low-back pain, and this risk may be influenced by several modifying factors. In the present study, we aimed to ...quantify the effects of continuous sitting and psychosocial stress under an unsupported sitting condition. Fourteen participants completed continuous, 40 min. periods of computer-based tasks, involving both low and higher levels of psychosocial stress, while using a laptop computer without a desk. Continuous sitting significantly increased perceived discomfort (particularly in the upper and lower back), trunk flexion and metrics of localized muscle fatigue. A higher level of psychosocial stress increased estimated lumbosacral compression forces (by ∼12%). Only weak correlations were found between subjective and objective measures, while various fatigue metrics showed a good level of correspondence with each other. These results could support the future evaluation or design of diverse seated work configurations. Practitioner Summary: Continuous, 40 min. periods of unsupported sitting had broad impacts on subjective and objective outcomes, including discomfort, postures, spine loads and localized muscle fatigue, while psychosocial stress only had a substantial influence on lumbosacral compression. These results extend our understanding of sitting behaviors and provide information for designing future sitting environments.
We present new 3 mm ATCA data of two Class I young stellar objects (YSOs) in the Ophiucus star forming region: Elias29 and WL12. For our analysis we compare them with archival 1.1 mm SMA data. In the ...(u,v) plane the two sources present a similar behavior: a nearly constant non-zero emission at long baselines, which suggests the presence of an unresolved component and an increase of the fluxes at short baselines, related to the presence of an extended envelope. Our data analysis leads to unusually low values of the spectral index α1.1−3 mm, which may indicate that mm-sized dust grains have already formed both in the envelopes and in the disk-like structures at such early stages. To explore the possible scenarios for the interpretation of the sources we perform a radiative transfer modeling using a Monte Carlo code, in order to take into account possible deviations from the Rayleigh-Jeans and optically thin regimes. Comparison between the model outputs and the observations indicates that dust grains may form aggregates up to millimeter size already in the inner regions of the envelopes of Class I YSOs. Moreover, we conclude that the embedded disk-like structures in our two Class I YSOs are probably very compact, in particular in the case of WL12, with outer radii down to tens of AU.
•Effects of smart glasses on gait stability and variability were assessed.•Using smart glasses reduced control over dynamics of lateral position.•Performing dual task activities decreased lateral ...gait stability.•Using smart glasses reduced gait stability less than smartphones.•Fall risk might be higher in the mediolateral direction during dual-task gait.
Head-worn displays (e.g., “smart glasses”) are an emerging technology to provide information, and in many situations they might be used while walking. However, little evidence exists regarding the effects of head-worn displays on walking performance. We found earlier that “smart glasses” had smaller adverse effects on measures of gait variability in the anterior-posterior direction vs. other types of information displays. Participants, however, complained about motion sickness and perceived instability while using smart glasses.
Were the participants’ complaints a result of adverse effects of the smart glasses on the dynamics of lateral stepping and gait stability?
Twenty individuals walked on a treadmill in four different conditions; single-task walking, and three dual-task walking conditions, the latter using smart glasses, smartphone, and a paper-based system to provide secondary cognitive tasks. We assessed the dynamics of lateral stepping and gait stability using the goal equivalent manifold and maximum Lyapunov exponent, respectively.
The dynamics of the lateral stepping were more adversely affected using smart glasses compared to the other types of information displays. However, stability measures revealed that the participants were more unstable when they used the smartphone and paper-based system.
Promising results in terms of stability and adaptability suggest that head-worn display technology is a potentially useful alternative to smartphones and other types of information displays for reducing the risk of a fall. Results regarding perceptions of instability and a loss of control over lateral stepping, however, imply that this technology requires further development prior to real-work implementations.
Back-support exoskeletons (BSEs) are a promising intervention to mitigate physical demands at work. Although growing evidence indicates that BSEs can reduce low-back physical demands, there is ...limited understanding of potential unintended consequences of BSE use, including the risk of falls.
Does using a BSE adversely affect gait performance and stability, and are such effects dependent on specific BSE external torque characteristics?
Twenty participants (10 M, 10 F) completed five level over-ground walking trials and a five-minute treadmill walking trial while wearing a BSE (backX™) with three different levels of external torque (i.e., no torque, low torque, and high torque) and in a control (no-exoskeleton) condition. Spatiotemporal gait patterns, stride-to-stride gait variability measures, required coefficient-of-friction (RCoF), and minimum foot clearance (MFC) were determined, to assess gait performance. Gait stability was quantified using the maximum Lyapunov exponent (MLE) of trunk kinematics and the margin-of-stability (MoS).
Using the backX™ with high supportive torque decreased slip risk (7% decrease in RCoF) and slightly improved trunk stability (3% decrease in MLE). However, it also decreased step length (1%), increased step width (10%) and increased gait variability (8–19%). Changes in MoS were complex: while MoS at heel strike decreased in the AP direction, it increased in the ML direction. There was a rather large decrease in MoS (26%) in the ML direction during the swing phase.
This is the first study to quantify the effects of wearing a passive BSE with multiple supportive torque levels on gait performance and stability during level walking. Our results, showing that the external torque of the BSE may adversely affect gait step width, variability, and dynamic stability, can contribute to better design and practice guidelines to facilitate the safe adoption of BSEs in the workplace.
•Changes in gait performance and stability when wearing a BSE were investigated.•BSE use altered gait pattern (decrease in step length and increase in step width).•BSE use decreased slip risk and slightly improved trunk stability.•BSE use, however, led to increase in gait variability.•BSE use decreased margin of stability (ML during swing and AP at heel strike).
Wearable sensors and systems have become increasingly popular in recent years. Two prominent wearable technologies for human activity monitoring are smart textile systems (STSs) and inertial ...measurement units (IMUs). Despite ongoing advances in both, the usability aspects of these devices require further investigation, especially to facilitate future use. In this study, 18 participants evaluate the preferred placement and usability of two STSs, along with a comparison to a commercial IMU system. These evaluations are completed after participants engaged in a range of activities (e.g., sitting, standing, walking, and running), during which they wear two representatives of smart textile systems: (1) a custom smart undershirt (SUS) and commercial smart socks; and (2) a commercial whole-body IMU system. We first analyze responses regarding the usability of the STS, and subsequently compared these results to those for the IMU system. Participants identify a short-sleeved shirt as their preferred activity monitor. In additional, the SUS in combination with the smart socks is rated superior to the IMU system in several aspects of usability. As reported herein, STSs show promise for future applications in human activity monitoring in terms of usability.