Abstract
Continuous glucose monitoring systems (CGM) are a very useful tool to understand the behaviour of glucose in different situations and populations. Despite the widespread use of CGM systems ...in both clinical practice and research, our understanding of the reproducibility of CGM data remains limited. The present work examines the reproducibility of the results provided by a CGM system in a random sample of a free-living adult population, from a functional data analysis approach. Functional intraclass correlation coefficients (ICCs) and their 95% confidence intervals (CI) were calculated to assess the reproducibility of CGM results in 581 individuals. 62% were females 581 participants (62% women) mean age 48 years (range 18–87) were included, 12% had previously been diagnosed with diabetes. The inter-day reproducibility of the CGM results was greater for subjects with diabetes (ICC 0.46 CI 0.39–0.55) than for normoglycaemic subjects (ICC 0.30 CI 0.27–0.33); the value for prediabetic subjects was intermediate (ICC 0.37 CI 0.31–0.42). For normoglycaemic subjects, inter-day reproducibility was poorer among the younger (ICC 0.26 CI 0.21–0.30) than the older subjects (ICC 0.39 CI 0.32–0.45). Inter-day reproducibility was poorest among normoglycaemic subjects, especially younger normoglycaemic subjects, suggesting the need to monitor some patient groups more often than others.
Background: Due to the high prevalence of nodular thyroid disease in the general population and the need to rule out malignant tumours, a clinical pathway for nodular thyroid disease was created at ...our tertiary-level hospital. Our study aimed to quantify timings and delays in diagnosis and treatment in this clinical pathway, specifically for patients who were diagnosed with thyroid cancer. Methods: A retrospective review was conducted of patients who were newly diagnosed with thyroid cancer and who had been previously evaluated in the clinical pathway for nodular thyroid disease at our institution during 2015–2017. Patient demographics, previous diagnostic studies, cytological results, tumour details and key dates were analysed to identify wait times in diagnosis and treatment. Results: Forty patients with thyroid cancer were included. The diagnostic delay had a median time of 60 days, and the treatment delay was dependent on cytopathological results. The main cause for delay in the diagnostic phase was the timing of the thyroid ultrasound performed by the radiology department. In the treatment phase, patients with a cytological result of Bethesda III, V or VI underwent surgery at the suggested time, while those in the Bethesda II or IV category did not. Conclusions: The major delay found in the diagnostic phase was the timing of the thyroid ultrasound performed by the radiology department. We are not suggesting that this step must be eliminated, though the implementation of routine ultrasonography in a thyroid clinic can help identify patients who need more urgent evaluation for fine needle aspiration cytology. In our hospital, decision for surgery is based mainly on the cytopathological report. Imaging studies and/or molecular testing could be considered to reduce treatment delays.
Aims
To investigate, in a sample of nondiabetic adults from a Spanish community, the differences between prediabetes as defined by HbA
1c
(“H-prediabetes”) and by fasting plasma glucose (FPG) ...(“F-prediabetes”) in regard to prevalence and the influence of potential risk factors, adjusting the latter for confounders.
Methods
A total of 1328 nondiabetic participants aged ≥ 18 years were classified as normoglycemic, H-prediabetic HbA
1c
5.7–6.4% (39–47 mmol/mol) or F-prediabetic (FPG 5.6–6.9 mmol/L). Multivariable analyses were used to compare the impacts of risk factors on the prevalence of H-prediabetes, F-prediabetes and their conjunctive and disjunctive combinations (“HaF-prediabetes” and “HoF-prediabetes,” respectively).
Results
Some 29.9% of participants were HoF-prediabetic, 21.7% H-prediabetic, 16.3% F-prediabetic and only 8.1% HaF-prediabetic. Whatever the definition of prediabetes, increasing age, fasting insulin and LDL cholesterol were each a risk factor after adjustment for all other variables. Increasing BMI and decreasing mean corpuscular hemoglobin (MCH) were additional risk factors for H-prediabetes; male sex and increasing uric acid for F-prediabetes and increasing BMI for HaF-prediabetes. The participants satisfying the compound condition “hypertension or hyperlipidemia or obesity or hyperuricemia” (59.9% of the whole study group) included 83.1% of all subjects with HoF-prediabetes.
Conclusions
In this population, the most sensitive risk factor for detection of prediabetes was age, followed by fasting insulin, LDL cholesterol, BMI, MCH, male sex and uric acid, with differences depending on the definition of prediabetes. MCH, an indirect measure of erythrocyte survival, significantly influences the prevalence of HbA
1c
-defined prediabetes. This study suggests that screening of individuals with selected risk factors may identify a high proportion of prediabetic persons.
There is a growing interest in the pathopysiological consequences of postprandial hyperglycemia. It is well known that in diabetic patients 2 h plasma glucose is a better risk predictor for coronary ...heart disease than fasting plasma glucose. Data on the glycemic response in healthy people are scarce.
To evaluate the effect of macronutrients (carbohydrates, fats, and proteins) and fiber on postprandial glycemic response in an observational study of a non-diabetic adult population.
Cross-sectional study. 150 non-diabetic adults performed continuous glucose monitoring for 6 days. During this period they recorded food and beverage intake. The participants were instructed not to make changes in their usual diet and physical exercise.Variables analyzed included clinical parameters (age, sex, body weight, height, body mass index, blood pressure, and waist measurement), meal composition (calories, carbohydrates, fats, proteins, and fiber) and glycemic postprandial responses separated by sexes.The study period was defined from the start of dinner to 6 h later.
A total of 148 (51% women) subjects completed all study procedures. Dinner intake was higher in males than in females (824 vs 531 kcal). Macronutrient distribution was similar in both sexes. No significant differences were found in fiber intake between men and women (5.5 g vs 4.5 g).In both sexes, the higher intake of carbohydrates corresponded to a significantly higher glycemic response (
= 0.0001 in women,
= 0.022 in men). Moreover, in women, as fat intake was higher, a flattening of the postprandial glycemic curve was observed (
= 0.003). With respect to fiber, a significantly lower glycemic response was observed in the group of women whose fiber intake at dinner was higher (
= 0.034).
Continuous glucose monitoring provides important information about glucose levels after meals. In this study, the postprandial glycemic response in women was different from that of men, and carbohydrates were the main determinant of elevated postprandial glucose levels.
Abstract Objectives Hypoglycemia is a limiting factor in the achievement of strict glycemic control. The primary objective of this 9-week study was to determine the frequency of hypoglycemia in ...patients with stable insulin-treated type 2 diabetes mellitus by comparing self-monitored blood glucose (SMBG) measurement with continuous glucose monitoring (CGM). Methods This was an observational prospective study. Included in the study were 63 stable, insulin-treated patients with type 2 diabetes. They were instructed to record 2 daily capillary blood glucose readings, pre- and/or postprandial, in a sequential way during 8 consecutive weeks. A CGM system was worn during an additional week. We evaluated the frequency of hypoglycemia using the 8-week SMBG profile and the 1 CGM week. Results SMBG revealed that 50% of the patients had experienced hypoglycemia. CGM found hypoglycemia in 59% of patients. Significantly higher percentages of hyperglycemic and hypoglycemic episodes were detected by CGM than by capillary blood glucose measurements (61.1% vs. 50.8%; p=0.047) and (3.8% vs. 1.7%; p=0.016); 33% of patients experienced nocturnal hypoglycemia, and 19% of patients who had no data concerning hypoglycemia recorded in the capillary blood glucose diary had experienced hypoglycemia as measured by CGM, and the hypoglycemia occurred mainly during the nocturnal period. Conclusions In stable well-controlled, insulin-treated patients with type 2 diabetes, CGM showed higher numbers of hypoglycemic events than did SMBG, especially at night. CGM is a useful tool that provides clinically valuable information about glucose control in these patients.
To investigate the prognostic value of time range metrics, as measured by continuous glucose monitoring, with respect to the development of type 2 diabetes (T2D).
A total of 499 persons without ...diabetes from the general population were followed-up for 5 years. Time range metrics were measured at the start and medical records were checked over the period study.
Twenty-two subjects (8.3 per 1,000 person-years) developed T2D. After adjusting for age, gender, family history of diabetes, body mass index and glycated hemoglobin concentration, multivariate analysis revealed 'time above range' (TAR, i.e., with a plasma glucose concentration of >140 mg/dL) to be significantly associated with a greater risk (OR = 1.06, CI 1.01-1.11) of developing diabetes (AUC = 0.94, Brier = 0.035).
Time above range provides additional information to that offered by glycated hemoglobin to identify patients at a higher risk of developing type 2 diabetes in a population-based study.
Advanced hybrid closed-loop systems (AHCL) have been shown to improve glycemic control and patient-reported outcomes in type 1 diabetes. The aim was to analyze the outcomes of two commercially ...available AHCL in real life.
A prospective study was performed, including adolescents and adults with type 1 diabetes, AHCL naïve, from 14 centers, who initiated the use of MM780G with SmartGuard or Tandem t:slimX2 with Control-IQ. Baseline and 3-month evaluations were performed, assessing HbA1c, time in different glycemic ranges, and patient-reported outcomes. The primary outcome was the between-group time in range 70-180 mg/dL difference from beginning to end of follow-up.
One hundred fifty participants were included, with 75 initiating each system (age: 39.9 ± 11.4 years 16-72; 64% female; diabetes duration: 21.6 ± 11.9 years). Time in range increased from 61.53 ± 14.01% to 76.17 ± 9.48% (P < 0.001), with no between-group differences (P = 0.591). HbA1c decreased by 0.56% (95% CI 0.44%, 0.68%) (6 mmol/mol, 95% CI 5, 7) (P < 0.001), from 7.43 ± 1.07% to 6.88 ± 0.60% (58 ± 12 to 52 ± 7 mmol/mol) in the MM780G group, and from 7.14 ± 0.70% to 6.56 ± 0.53% (55 ± 8 to 48 ± 6 mmol/mol) in the Control-IQ group (both P < 0.001 to baseline, P = 0.819 between groups). No superiority of one AHCL over the other regarding fear of hypoglycemia or quality of life was found. Improvement in diabetes-related distress was higher in Control-IQ users (P = 0.012). Sleep quality was improved (PSQI: from 6.94 ± 4.06 to 6.06 ± 4.05, P = 0.004), without differences between systems. Experience with AHCL, evaluated by the INSPIRE measures, exceeded the expectations.
The two AHCL provide significant improvement in glucose control and satisfaction, with no superiority of one AHCL over the other.
Aims: This study aimed to determine the effect of aging on glucose profiles in a population without diabetes. Methods: We investigated the evolution of glucose profiles in an adult population without ...diabetes using continuous glucose monitoring (CGM) in two periods separated by 5 years. Anthropometrics, laboratory tests (HbA1c, fasting blood glucose) and CGM data (mean glycemia level, coefficient of variation, time in range) were measured in both periods to study the change in values over time. Results: 125 participants (68% women) mean age 43.1 ± 12.4 years and classified as normoglycemic at baseline were included. Of the total population 15.2% had worsened glycemic status after 5 years, age and baseline glucose values (HbA1c and percentage of values above 175 mg/dL) were the variables related with this change. Related to CGM, we found that after 5 years there was a decrease in the percentage of values between 70 and 99 mg/dl (45.0% to 38.7%, p = 0.002) and an increase in the 100–139 mg/dL range (52.9% to 57.5% p = 0.016). Conclusions: Our results indicate that in an adult population without diabetes there are changes in glucose profiles with aging highlighting the reduction of blood glucose values below 100 mg/dL.
•A comprehensive assessment must be the starting point of every educational intervention for older adults.•The interventions should adapt to the needs of the older adults and not the other way ...around.•Key elements for success are ongoing support, individualization, and family/caregiver involvement.
This systematic review aimed to assess the effectiveness of educational interventions in type 2 diabetes specifically designed for community-dwelling older adults.
In accordance with PRISMA guidelines, a systematic search of studies published between 2010 and 2021 was conducted across five electronic databases and manual sources. The study protocol was previously registered in PROSPERO (CRD42021288236).
Twelve papers matched the inclusion criteria and were appraised using MERSQI. The features of the educational programs were heterogeneous, and none complied with the ten suggested standards for diabetes self-management education and support. Comprehensive gerontological assessment was not considered. Outcomes included biomedical, psychosocial, behavioral, and knowledge measures. HbA1c and knowledge showed improvements with a high certainty level according to GRADE.
Structured DSME programs aimed at older adults have great potential, however there is still room to improve. Applying the principles of a comprehensive gerontological approach and the standards for DSME as continuous monitoring and support could increase their benefits.