One-fourth of colorectal neoplasias are missed during screening colonoscopies; these can develop into colorectal cancer (CRC). Deep learning systems allow for real-time computer-aided detection ...(CADe) of polyps with high accuracy. We performed a multicenter, randomized trial to assess the safety and efficacy of a CADe system in detection of colorectal neoplasias during real-time colonoscopy.
We analyzed data from 685 subjects (61.32 ± 10.2 years old; 337 men) undergoing screening colonoscopies for CRC, post-polypectomy surveillance, or workup due to positive results from a fecal immunochemical test or signs or symptoms of CRC, at 3 centers in Italy from September through November 2019. Patients were randomly assigned (1:1) to groups who underwent high-definition colonoscopies with the CADe system or without (controls). The CADe system included an artificial intelligence–based medical device (GI-Genius, Medtronic) trained to process colonoscopy images and superimpose them, in real time, on the endoscopy display a green box over suspected lesions. A minimum withdrawal time of 6 minutes was required. Lesions were collected and histopathology findings were used as the reference standard. The primary outcome was adenoma detection rate (ADR, the percentage of patients with at least 1 histologically proven adenoma or carcinoma). Secondary outcomes were adenomas detected per colonoscopy, non-neoplastic resection rate, and withdrawal time.
The ADR was significantly higher in the CADe group (54.8%) than in the control group (40.4%) (relative risk RR, 1.30; 95% confidence interval CI, 1.14–1.45). Adenomas detected per colonoscopy were significantly higher in the CADe group (mean, 1.07 ±1.54) than in the control group (mean 0.71 ± 1.20) (incidence rate ratio, 1.46; 95% CI, 1.15–1.86). Adenomas 5 mm or smaller were detected in a significantly higher proportion of subjects in the CADe group (33.7%) than in the control group (26.5%; RR, 1.26; 95% CI, 1.01–1.52), as were adenomas of 6 to 9 mm (detected in 10.6% of subjects in the CADe group vs 5.8% in the control group; RR, 1.78; 95% CI, 1.09–2.86), regardless of morphology or location. There was no significant difference between groups in withdrawal time (417 ± 101 seconds for the CADe group vs 435 ± 149 for controls; P = .1) or proportion of subjects with resection of non-neoplastic lesions (26.0% in the CADe group vs 28.7% of controls; RR, 1.00; 95% CI, 0.90–1.12).
In a multicenter, randomized trial, we found that including CADe in real-time colonoscopy significantly increases ADR and adenomas detected per colonoscopy without increasing withdrawal time. ClinicalTrials.gov no: 04079478
Display omitted
False positive (FP) results by computer-aided detection (CADe) hamper the efficiency of colonoscopy by extending examination time. Our aim was to develop a classification of the causes and clinical ...relevance of CADe FPs, and to assess the relative distribution of FPs in a real-life setting.
In a post-hoc analysis of a randomized trial comparing colonoscopy with and without CADe (NCT: 04079478), we extracted 40 CADe colonoscopy videos. Using a modified Delphi process, 4 expert endoscopists identified the main domains for the reasons and clinical relevance of FPs. Then, 2 expert endoscopists manually examined each FP and classified it according to the proposed domains. The analysis was limited to the withdrawal phase.
The 2 main domains for the causes of CADe FPs were identified as artifacts due to either the mucosal wall or bowel content, and clinical relevance was defined as the time spent on FPs and the FP rate per minute. The mean number of FPs per colonoscopy was 27.3 ± 13.1, of which 24 ± 12 (88%) and 3.2 ± 2.6 (12%) were due to artifacts in the bowel wall and bowel content, respectively. Of the 27.3 FPs per colonoscopy, 1.6 (5.7%) required additional exploration time of 4.8 ± 6.2 seconds per FP (ie, 0.7% of the mean withdrawal time). In detail, 15 (24.2%), 33 (53.2%), and 14 (22.6%) FPs were classified as being of mild, moderate, or severe clinical relevance. The rate of FPs per minute of withdrawal time was 2.4 ± 1.2, and was higher for FPs due to artifacts from the bowel wall than for those from bowel content (2.4 ± 0.6 vs 0.3 ± 0.2, P < .001).
FPs by CADe are primarily due to artifacts from the bowel wall. Despite a high frequency, FPs result in a negligible 1% increase in the total withdrawal time because most of them are immediately discarded by the endoscopist.
In recent years, the feasibility and safety of endoscopic placement of different biodegradable biliary stents have been investigated. New, helicoidally shaped, biliary and pancreatic biodegradable ...stents have been developed for endoscopic use. Stents are provided in different sizes and with 3 expected speeds of degradation: slow (11 weeks), medium (20 days), and fast (12 days). The aim of this study was to evaluate degradation time, technical outcomes, and safety of these stents.
This was a single-center, prospective, pilot study (August 2018 to January 2019) of consecutive patients with indication for biliary or pancreatic plastic stent positioning during ERCP. The primary outcome was the evaluation of degradation time of the stents, which was controlled by abdominal radiograph. Secondary outcomes were the evaluation of specific stent-related technical features (loadability, pushability, and fluoroscopic visibility) as compared with commonly used plastic stents and adverse events (AEs).
Thirty-eight patients (11 women 28.9%; median age, 68.05 ± 10.74 years) who received 53 biodegradable stents (34 64.2% biliary and 19 35.8% pancreatic stents) were enrolled in the study. Thirty-five (66%) slow-degrading stents, 6 (11.3%) medium-degrading stents, and 12 (22.6%) fast-degrading stents were used. At time 1, partial degradation of the stents was present in 48 cases (90.6%). Five stents (9.4%) prematurely migrated. At the subsequent time 2 evaluation, complete degradation occurred in 100% of cases. Stent loadability was defined as excellent in all cases. Pushability of the stent was scored as excellent in 48 cases (90.5%), good in 4 cases (7.5%), and fair in 1 case (1.9%). Fluoroscopic visualization was excellent in 11 cases (20.8%), good in 39 cases (73.6%), and fair in 3 (5.6%). Only 1 AE of mild post-ERCP pancreatitis occurred.
The results of our study suggest that the biodegradation of the new biliary and pancreatic stents is reliable and in line with expected times and technically successful in a variety of indications. Further randomized multicenter studies are required to validate our preliminary findings. (Clinical trial registration number: NCT03767166.)
Eosinophilic esophagitis (EoE) is a chronic immune-mediated disease of the esophagus characterized clinically by symptoms related to esophageal dysfunction and histologically by ...eosinophil-predominant inflammation, whose incidence is rising. It significantly affects patients' quality of life and, if left untreated, results in fibrotic complications. Although broad consensus has been achieved on first-line therapy, a subset of patients remains non-responder to standard therapy. The pathogenesis of EoE is multifactorial and results from the complex, still mostly undefined, interaction between genetics and intrinsic factors, environment, and antigenic stimuli. A deep understanding of the pathophysiology of this disease is pivotal for the development of new therapies. This review provides a comprehensive description of the pathophysiology of EoE, starting from major pathogenic mechanisms (genetics, type 2 inflammation, epithelial barrier dysfunction, gastroesophageal reflux, allergens, infections and microbiota) and subsequently focusing on the single protagonists of type 2 inflammation (involved cells, cytokines, soluble effectors, surface proteins and transcription factors) that could represent present and future therapeutic targets, while summarizing previous therapeutic approaches in literature.
Multiple therapeutic modalities including surgery and rigid and flexible endoscopy have been adopted to manage Zenker's diverticulum (ZD). Minimally invasive flexible endoscopic septotomy (FES) ...techniques have been increasingly favored over the past 20 years; however, long-term data are still scanty. The aim of this study is to evaluate early and long-term outcomes of FES for naive ZD in a single-center setting.
From 2010 to 2017, ZD patients treated with FES were included in a prospectively maintained database (NCT03948438). Those who had already been treated surgically or endoscopically were excluded from the analysis. The Dakkak and Bennett dysphagia scale was used to rate the dysphagia. Persistent complete or near-complete resolution of symptoms (Dakkak and Bennett 0 or 1) was defined as clinical success. Postprocedural adverse events were reported according to ASGE lexicon.
Overall, 256 consecutive patients were treated. Mean pouch size was 29.8 ± 11.3 mm. The procedure was successfully completed in all scheduled patients, with an early clinical success of 96.1%. Adverse events occurred in 3.5% (9/256) of patients. Eight of them were mild/moderate with no fatal events, whereas one patient required surgery. Recurrences occurred in 31.3% (80/256) of treated patients after a mean time of 9 ± 3 months and 95% of recurrences were treated by a second FES. At an average follow-up of 5.5 years, 95.3% of patients were asymptomatic after a mean number of 1.3 procedures.
FES is a safe and effective treatment modality for patients with ZD. Recurrence rate is significant; however, endoscopic reintervention is associated with long-term relief of dysphagia.
Background:
The endoscopic submucosal dissection (ESD) is a technically demanding and time-consuming procedure, with an increased risk of adverse events compared to standard endoscopic resection ...techniques. The main difficulties are related to the instability of the operating field and to the loss of traction. We aimed to evaluate in a pilot trial a new endoscopic platform tissue retractor system (TRS); ORISE, Boston scientific Co., Marlborough, MA, USA, designed to stabilize the intraluminal space, and to provide tissue retraction and counter traction.
Method:
We prospectively enrolled all consecutive patients who underwent an ESD for sigmoid/rectal lesions. The primary outcome was the rate of technical feasibility. Further technical aspects such as en-bloc and R0 resection rate, number of graspers used, circumferential incision time, TRS assemblage time, submucosal dissection time, and submucosal dissection speed were provided. Clinical outcomes (recurrence rate and adverse events) were recorded as well.
Results:
In all, 10 patients (M/F 4/6, age: 70.4 ± 11.0 years old) were enrolled. Eight out of 10 lesions were located in the rectum. Average lesion size was 31.2 ± 2.7 mm, and mean lesion area was 1628.88 ± 205.3 mm2. The two sigmoid lesions were removed through standard ESD, because the platform assemblage failed after several attempts. All rectal lesions were removed in an en-bloc fashion. R0 resection was achieved in 7/8 (87.5%) patients in an average procedure time of 60.5 ± 23.3 min. None of the patients developed neither intraprocedural nor postprocedural adverse events.
Conclusion:
TRS-assisted ESD is a feasible option when used in the rectum, with promising result in terms of efficacy and safety outcomes. Nevertheless, our pilot study underlines few technical limitations of the present platform that need to be overcome before the system could be widely and routinely used.
In the last 30 years, we have witnessed a rapid increase in the incidence and prevalence of esophageal cancer in many countries around the word. However, despite advancements in diagnostic ...technologies, the early detection of this cancer is rare, and its prognosis remains poor, with only about 20% of these patients surviving for 5 years. The two major forms are the esophageal squamous cell carcinoma (ESCC), which is particularly frequent in the so-called Asian belt, and the esophageal adenocarcinoma (EAC), which prevails in Western populations. This review provides a summary of the epidemiological features and risk factors associated with these tumors. Moreover, a major focus is posed on reporting and highlighting the various preventing strategies proposed by the most important international scientific societies, particularly in high-risk populations, with the final aim of detecting these lesions as early as possible and therefore favoring their definite cure. Indeed, we have conducted analysis with attention to the current primary, secondary and tertiary prevention guidelines in both ESCC and EAC, attempting to emphasize unresolved research and clinical problems related to these topics in order to improve our diagnostic strategies and management.
The gut microbiota is emerging as an important player in neurodevelopment and aging as well as in brain diseases including stroke, Alzheimer’s disease, and Parkinson’s disease. The complex interplay ...between gut microbiota and the brain, and vice versa, has recently become not only the focus of neuroscience, but also the starting point for research regarding many diseases such as inflammatory bowel diseases (IBD). The bi-directional interaction between gut microbiota and the brain is not completely understood. The aim of this review is to sum up the evidencesconcerningthe role of the gut–brain microbiota axis in ischemic stroke and to highlight the more recent evidences about the potential role of the gut–brain microbiota axis in the interaction between inflammatory bowel disease and ischemic stroke.
Introduction: Achalasia following bariatric surgery is a rare phenomenon with diverse potential physiopathological origins. Aims: This article aims to explore the hypothetical physiopathological ...connection between bariatric surgery and the subsequent onset of achalasia. Material and Methods: A review was conducted to identify studies reporting cases of peroral endoscopic myotomy (POEM) after bariatric procedures and detailing the outcomes in terms of the technical and clinical success. Additionally, a case of a successful POEM performed on a patient two years after undergoing laparoscopic sleeve gastrectomy (LSG) is presented. Results: The selection criteria yielded eight studies encompassing 40 patients treated with POEM for achalasia after bariatric surgery: 34 after Roux-en-Y gastric bypass (RYGB) and 6 after LSG. The studies reported an overall technical success rate of 97.5%, with clinical success achieved in 85% of cases. Adverse events were minimal, with only one case of esophageal leak treated endoscopically. However, a postprocedural symptomatic evaluation was notably lacking in most of the included studies. Conclusions: Achalasia poses a considerable challenge within the bariatric surgery population. POEM has emerged as a technically viable and safe intervention for this patient demographic, providing an effective treatment option where surgical alternatives for achalasia are limited. Our findings highlight the promising outcomes of POEM in these patients, but the existing data remain limited. Hence, prospective studies are needed to elucidate the optimal pre-surgical assessment and timing of endoscopic procedures for optimizing outcomes.
Chronic idiopathic intestinal pseudo-obstruction (CIIPO) is a disease characterized by symptoms and signs of small bowel obstruction in the absence of displayable mechanical obstruction. Due to the ...known neuropathic capacity of several viruses, and their localization in the intestine, it has been hypothesized that such viruses could be involved in the pathogenesis of CIIPO. The most frequently involved viruses are John Cunningham virus, Herpesviridae, Flaviviruses, Epstein-Barr virus and Citomegalovirus. Therefore, the present narrative review aims to sum up some new perspectives in the etiology and pathophysiology of CIIPO.