This meta-analysis aims to quantify the association of reduced coronary flow with all-cause mortality and major adverse cardiovascular events (MACE) across a broad range of patient groups and ...pathologies.
We systematically identified all studies between 1 January 2000 and 1 August 2020, where coronary flow was measured and clinical outcomes were reported. The endpoints were all-cause mortality and MACE. Estimates of effect were calculated from published hazard ratios (HRs) using a random-effects model. Seventy-nine studies with a total of 59 740 subjects were included. Abnormal coronary flow reserve (CFR) was associated with a higher incidence of all-cause mortality HR: 3.78, 95% confidence interval (CI): 2.39-5.97 and a higher incidence of MACE (HR 3.42, 95% CI: 2.92-3.99). Each 0.1 unit reduction in CFR was associated with a proportional increase in mortality (per 0.1 CFR unit HR: 1.16, 95% CI: 1.04-1.29) and MACE (per 0.1 CFR unit HR: 1.08, 95% CI: 1.04-1.11). In patients with isolated coronary microvascular dysfunction, an abnormal CFR was associated with a higher incidence of mortality (HR: 5.44, 95% CI: 3.78-7.83) and MACE (HR: 3.56, 95% CI: 2.14-5.90). Abnormal CFR was also associated with a higher incidence of MACE in patients with acute coronary syndromes (HR: 3.76, 95% CI: 2.35-6.00), heart failure (HR: 6.38, 95% CI: 1.95-20.90), heart transplant (HR: 3.32, 95% CI: 2.34-4.71), and diabetes mellitus (HR: 7.47, 95% CI: 3.37-16.55).
Reduced coronary flow is strongly associated with increased risk of all-cause mortality and MACE across a wide range of pathological processes. This finding supports recent recommendations that coronary flow should be measured more routinely in clinical practice, to target aggressive vascular risk modification for individuals at higher risk.
Our understanding of human coronary physiological behaviour is derived from animal models. We sought to describe physiological behaviour across a large collection of invasive pressure and flow ...velocity measurements, to provide a better understanding of the relationships between these physiological parameters and to evaluate the rationale for resting stenosis assessment.
Five hundred and sixty-seven simultaneous intracoronary pressure and flow velocity assessments from 301 patients were analysed for coronary flow velocity, trans-stenotic pressure gradient (TG), and microvascular resistance (MVR). Measurements were made during baseline and hyperaemic conditions. The whole cardiac cycle and the diastolic wave-free period were assessed. Stenoses were assessed according to fractional flow reserve (FFR) and quantitative coronary angiography DS%. With progressive worsening of stenoses, from unobstructed angiographic normal vessels to those with FFR ≤ 0.50, hyperaemic flow falls significantly from 45 to 19 cm/s, Ptrend < 0.001 in a curvilinear pattern. Resting flow was unaffected by stenosis severity and was consistent across all strata of stenosis (Ptrend > 0.05 for all). Trans-stenotic pressure gradient rose with stenosis severity for both rest and hyperaemic measures (Ptrend < 0.001 for both). Microvascular resistance declines with stenosis severity under resting conditions (Ptrend < 0.001), but was unchanged at hyperaemia (2.3 ± 1.1 mmHg/cm/s; Ptrend = 0.19).
With progressive stenosis severity, TG rises. However, while hyperaemic flow falls significantly, resting coronary flow is maintained by compensatory reduction of MVR, demonstrating coronary auto-regulation. These data support the translation of coronary physiological concepts derived from animals to patients with coronary artery disease and furthermore, suggest that resting pressure indices can be used to detect the haemodynamic significance of coronary artery stenoses.
Abstract Background Sympathetic overactivation, is reduced by renal denervation in drug-resistant hypertension. A similar role for renal denervation in heart failure remains unstudied, partly due to ...the concern about potential concomitant deleterious blood pressure reductions. This pilot study evaluated the safety of renal denervation for heart failure using an intensive follow-up protocol. Method 7 patients (mean age 69 years) with chronic systolic heart failure (mean BP on referral 112/65 mm Hg) on maximal tolerated heart failure therapy underwent bilateral renal denervation May–July 2011. Patients were admitted for pre-procedure baseline assessments and in-patient observation for 5 days following denervation. Follow-up was weekly for 4 weeks, and then monthly for 6 months. Results No significant haemodynamic disturbances were noted during the acute phase post renal denervation. Over 6 months there was a non-significant trend to blood pressure reduction (Δsystolic − 7.1 ± 6.9 mm Hg, p = 0.35; Δdiastolic − 0.6 ± 4.0 mm Hg, p = 0.88). No hypotensive or syncopal episodes were reported. Renal function remained stable (Δcreatinine − 5.7 ± 8.4 μmol/l, p = 0.52 and Δurea − 1.0 ± 1.0 mmol/l, p = 0.33). All 7 patients described themselves as symptomatically improved. The six minute walk distance at six months was significantly increased (Δ = 27.1 ± 9.7 m, p = 0.03), with each patient showing an increase. Conclusions This study found no procedural or post procedural complications following renal denervation in patients with chronic systolic heart failure in 6 months of intensive follow-up. Results suggested improvements in both symptoms and exercise capacity, but further randomised, blinded sham-controlled clinical trials are required to determine the impact of renal denervation on morbidity and mortality in systolic heart failure. These data suggest such trials will be safe.
Objectives This study sought to examine the diagnostic accuracy of the instantaneous wave-free ratio (iFR) and resting distal coronary artery pressure/aortic pressure (P d /P a ) with respect to ...hyperemic fractional flow reserve (FFR) in a core laboratory–based multicenter collaborative study. Background FFR is an index of the severity of coronary stenosis that has been clinically validated in 3 prospective randomized trials. iFR and P d /P a are nonhyperemic pressure-derived indices of the severity of stenosis with discordant reports regarding their accuracy with respect to FFR. Methods iFR, resting P d /P a , and FFR were measured in 1,768 patients from 15 clinical sites. An independent physiology core laboratory performed blinded off-line analysis of all raw data. The primary objectives were to determine specific iFR and P d /P a thresholds with ≥90% accuracy in predicting ischemic versus nonischemic FFR (on the basis of an FFR cut point of 0.80) and the proportion of patients falling beyond those thresholds. Results Of 1,974 submitted lesions, 381 (19.3%) were excluded because of suboptimal acquisition, leaving 1,593 for final analysis. On receiver-operating characteristic analysis, the optimal iFR cut point for FFR ≤0.80 was 0.90 (C statistic: 0.81 95% confidence interval: 0.79 to 0.83; overall accuracy: 80.4%) and for P d /P a was 0.92 (C statistic: 0.82 95% confidence interval: 0.80 to 0.84; overall accuracy: 81.5%), with no significant difference between these resting measures. iFR and P d /P a had ≥90% accuracy to predict a positive or negative FFR in 64.9% (62.6% to 67.3%) and 48.3% (45.6% to 50.5%) of lesions, respectively. Conclusions This comprehensive core laboratory analysis comparing iFR and P d /P a with FFR demonstrated an overall accuracy of ∼80% for both nonhyperemic indices, which can be improved to ≥90% in a subset of lesions. Clinical outcome studies are required to determine whether the use of iFR or P d /P a might obviate the need for hyperemia in selected patients.
Abstract Advances in the understanding of healing mechanisms after stent implantation have led to the recognition of stent strut thickness as an essential factor affecting re-endothelialization and ...overall long term vessel healing response after Percutaneous Coronary Interventions (PCI). Emergence of Drug-eluting stents (DESs) with anti-proliferative coating has contributed to reducing the incidence of restenosis and Target Lesion Revascularization (TVR), while progress and innovations in stent materials have in the meantime facilitated the design of newer platforms with more conformability and thinner struts, producing lesser injury and improving integration into the vessel wall. Recent advances in biodegradable metal and polymer materials now also allow for the design of fully biodegradable platforms, which are aimed at scaffolding the vessel only temporarily to prevent recoil and constrictive remodeling of the vessel during the initial period required, and are then progressively resorbed thereby avoiding the drawback of leaving an unnecessary implant permanently in the vessel. The aim of this article is to review recent evolution in stent material and stent strut design while understanding their impact on PCI outcomes. The article describes the different metallic alloys and biodegradable material properties and how these have impacted the evolution of stent strut thickness and ultimately outcomes in patients.
Pressure-wire technology, most typically fractional flow reserve (FFR), has provided interventional cardiologists with a means of determining the physiological importance of a stenosis during ...angiography. There has been renewed interest in coronary physiology in the light of guideline recognition, ongoing clinical research and new technologies changing the paradigm of how assessment is performed in the catheter laboratory. We reflect on FFR, with regards the potential effects of changing hemodynamics on FFR and the latest evidence with regards to outcomes. We also review the instantaneous wave-free ratio (iFR), a new pressure-only index, measured at rest, that is under active evaluation in several international randomized controlled trials. We review the accumulated evidence and discuss the important physiological concepts between pressure and flow that underlie the approach to using resting indices. Finally we investigate future developments, including physiological mapping with iFR-Pullback and the potential to predict the hemodynamic effect of stenting. (Circ J 2015; 79: 1172–1184)
The aim of this study was to assess the long-term clinical outcomes of patients with left main coronary artery (LM) stenosis in whom treatment strategy was based on the instantaneous wave-free ratio ...(iFR).
The overall safety of iFR to guide revascularization decision making in patients with stable coronary artery disease has been established. However, no study has examined the safety of deferral of revascularization of LM disease on the basis of iFR.
This multicenter observational study included 314 patients in whom LM stenosis was deferred (n = 163 51.9%) or revascularized (n = 151 48.1%) according to the iFR cutoff ≤0.89. The primary endpoint was a composite of all-cause death, nonfatal myocardial infarction, and ischemia-driven target lesion revascularization. The secondary endpoints were each individual component of the primary endpoint and also cardiac death.
At a median follow-up period of 30 months, the primary endpoint occurred in 15 patients (9.2%) in the deferred group and 22 patients (14.6%) in the revascularized group (hazard ratio: 1.45; 95% confidence interval: 0.75 to 2.81; p = 0.26), indicating no evidence of a significant difference between the 2 groups. For the secondary endpoints, findings in the iFR-based deferral and revascularization groups were as follows: all-cause death, 3.7% versus 4.6%; cardiac death, 1.2% versus 2.0%; nonfatal myocardial infarction, 2.5% versus 5.3%; and target lesion revascularization, 4.3% versus 5.3% (p > 0.05 for all).
Deferral of revascularization of LM stenosis on the basis of iFR appears to be safe, with similar long-term outcomes to those in patients in whom LM revascularization was performed according to iFR values.
Display omitted
Fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR) disagree on the hemodynamic significance of a coronary lesion in ≈20% of cases. It is unknown whether the physiological pattern ...of disease is an influencing factor for this. This study assessed whether the physiological pattern of coronary artery disease influences discordance between FFR and iFR measurement.
Three-hundred and sixty intermediate coronary lesions (345 patients; mean age, 64.4±10.3 years; 76% men) with combined FFR, iFR, and iFR pressure-wire pullback were included for analysis from an international multicenter registry. Cut points for hemodynamic significance were FFR ≤0.80 and iFR ≤0.89, respectively. Lesions were classified into FFR+/iFR+ (n=154; 42.7%), FFR-/iFR+ (n=38; 10.6%), FFR+/iFR- (n=41; 11.4%), and FFR-/iFR- (n=127; 35.3%) groups. The physiological pattern of disease was classified according to the iFR pullback recordings as predominantly physiologically focal (n=171; 47.5%) or predominantly physiologically diffuse (n=189; 52.5%). Median FFR and iFR were 0.80 (interquartile range, 0.75-0.85) and 0.89 (interquartile range, 0.86-0.92), respectively. FFR disagreed with iFR in 22% (79 of 360). The physiological pattern of disease was the only influencing factor relating to FFR/iFR discordance: predominantly physiologically focal was significantly associated with FFR+/iFR- (58.5% 24 of 41), and predominantly physiologically diffuse was significantly associated with FFR-/iFR+ (81.6% 31 of 38; P<0.001 for pattern of disease between FFR+/iFR- and FFR-/iFR+ groups).
The physiological pattern of coronary artery disease was an important influencing factor for FFR/iFR discordance.
To evaluate the classification agreement between instantaneous wave-free ratio (iFR) and fractional flow reserve (FFR) in patients with angiographic intermediate coronary stenoses.
Three hundred and ...twelve patients (339 stenoses) with angiographically intermediate stenoses were included in this international clinical registry. The iFR was calculated using fully automated algorithms. The receiver operating characteristic (ROC) curve was used to identify the iFR optimal cut-point corresponding to FFR 0.8. The classification agreement of coronary stenoses as significant or non-significant was established between iFR and FFR and between repeated FFR measurements for each 0.05 quantile of FFR values, from 0.2 to 1. Close agreement was observed between iFR and FFR (area under ROC curve= 86%). The optimal iFR cut-off (for an FFR of 0.80) was 0.89. After adjustment for the intrinsic variability of FFR, the classification agreement (accuracy) between iFR and FFR was 94%. Amongst the stenoses classified as non-significant by iFR (>0.89) and as significant by FFR (≤0.8), 81% had associated FFR values located within the FFR "grey-zone" (0.75-0.8) and 41% within the 0.79-0.80 FFR range.
In a population of intermediate coronary stenoses, the classification agreement between iFR and FFR is excellent and similar to that of repeated FFR measurements in the same sample. Vasodilator-independent assessment of intermediate stenosis seems applicable and may foster adoption of coronary physiology in the catheterisation laboratory.