The experimental results on the ratios of branching fractions R(D)=B(Bover ¯→Dτ^{-}νover ¯_{τ})/B(Bover ¯→Dℓ^{-}νover ¯_{ℓ}) and R(D^{*})=B(Bover ¯→D^{*}τ^{-}νover ¯_{τ})/B(Bover ¯→D^{*}ℓ^{-}νover ...¯_{ℓ}), where ℓ denotes an electron or a muon, show a long-standing discrepancy with the standard model predictions, and might hint at a violation of lepton flavor universality. We report a new simultaneous measurement of R(D) and R(D^{*}), based on a data sample containing 772×10^{6} BBover ¯ events recorded at the ϒ(4S) resonance with the Belle detector at the KEKB e^{+}e^{-} collider. In this analysis the tag-side B meson is reconstructed in a semileptonic decay mode and the signal-side τ is reconstructed in a purely leptonic decay. The measured values are R(D)=0.307±0.037±0.016 and R(D^{*})=0.283±0.018±0.014, where the first uncertainties are statistical and the second are systematic. These results are in agreement with the standard model predictions within 0.2, 1.1, and 0.8 standard deviations for R(D), R(D^{*}), and their combination, respectively. This work constitutes the most precise measurements of R(D) and R(D^{*}) performed to date as well as the first result for R(D) based on a semileptonic tagging method.
A
bstract
We present measurements of the branching fractions for the decays
B
→
Kμ
+
μ
−
and
B
→
Ke
+
e
−
, and their ratio (
R
K
), using a data sample of 711 fb
−
1
that contains 772 × 10
6
B
B
¯
...events. The data were collected at the ϒ(4
S
) resonance with the Belle detector at the KEKB asymmetric-energy
e
+
e
−
collider. The ratio
R
K
is measured in five bins of dilepton invariant-mass-squared (
q
2
):
q
2
∈ (0
.
1
,
4
.
0)
,
(4
.
00
,
8
.
12)
,
(1
.
0
,
6
.
0), (10
.
2
,
12
.
8) and (
>
14
.
18) GeV
2
/c
4
, along with the whole
q
2
region. The
R
K
value for
q
2
∈ (1
.
0
,
6
.
0) GeV
2
/c
4
is
1.03
−
0.24
+
0.28
± 0
.
01. The first and second uncertainties listed are statistical and systematic, respectively. All results for
R
K
are consistent with Standard Model predictions. We also measure
CP
-averaged isospin asymmetries in the same
q
2
bins. The results are consistent with a null asymmetry, with the largest difference of 2.6 standard deviations occurring for the
q
2
∈ (1
.
0
,
6
.
0) GeV
2
/c
4
bin in the mode with muon final states. The measured differential branching fractions,
d
ℬ
/dq
2
, are consistent with theoretical predictions for charged
B
decays, while the corresponding values are below the expectations for neutral
B
decays. We have also searched for lepton-flavor-violating
B
→
Kμ
±
e
∓
decays and set 90% confidence-level upper limits on the branching fraction in the range of 10
−
8
for
B
+
→
K
+
μ
±
e
∓
, and
B
0
→
K
0
μ
±
e
∓
modes.
A
bstract
Charged lepton flavor violation is forbidden in the Standard Model but possible in several new physics scenarios. In many of these models, the radiative decays
τ
±
→
ℓ
±
γ
(
ℓ
=
e, μ
) are ...predicted to have a sizeable probability, making them particularly interesting channels to search at various experiments. An updated search via
τ
±
→
ℓ
±
γ
using full data of the Belle experiment, corresponding to an integrated luminosity of 988 fb
−
1
, is reported for charged lepton flavor violation. No significant excess over background predictions from the Standard Model is observed, and the upper limits on the branching fractions,
B
(
τ
±
→
μ
±
γ
) ≤ 4
.
2 × 10
−
8
and
B
(
τ
±
→
e
±
γ
) ≤ 5
.
6 × 10
−
8
, are set at 90% confidence level.
We report the first observation of the spontaneous polarization of Λ and Λover ¯ hyperons transverse to the production plane in e^{+}e^{-} annihilation, which is attributed to the effect arising from ...a polarizing fragmentation function. For inclusive Λ/Λover ¯ production, we also report results with subtracted feed-down contributions from Σ^{0} and charm. This measurement uses a dataset of 800.4 fb^{-1} collected by the Belle experiment at or near a center-of-mass energy of 10.58 GeV. We observe a significant polarization that rises with the fractional energy carried by the Λ/Λover ¯ hyperon.
Laterally spreading tumors - non granular type (LST-NG) are more often considered candidates for endoscopic submucosal dissection (ESD) than laterally spreading tumors - granular type (LST-G), ...because of their higher potential for submucosal invasion. However, ESD for LST-NG can be technically difficult. The aim of our study was to compare our ESD results for LST-NG and for LST-G.
Ninety-nine LST-NG and 169 LST-G measuring 20 mm in size or more were removed by ESD. We retrospectively evaluated the clinicopathological features of the tumors and treatment results (en bloc resection rate, procedure time and speed, rate of use of ancillary devices, and complication and recurrence rates).
Histopathology revealed that there were more submucosally invasive lesions in the LST-NG than in the LST-G group (28 % vs. 9 %; P < 0.0001). The en bloc resection rate, en bloc R0 resection rate, and en bloc curative resection rate of LST-NG were similar to those of LST-G (LST-NG: 99 %, 98 %, and 88 %; LST-G: 99 %, 98 %, and 91 %). In LST-NG, the median procedure time tended to be longer (LST-NG: 69 min; LST-G: 60 min) and the median procedure speed was slower (LST-NG: 0.15 cm (2)/min; LST-G: 0.25 cm (2)/min; P < 0.0001). Use of ancillary devices was higher for LST-NG (38 % vs. 15 % for LST-G; P < 0.0001), as was the perforation rate (5.1 % vs. 0.6 % for LST-G; P = 0.027). No recurrence was seen in either group.
ESD was an effective treatment method for both LST-NG and LST-G. However, the degree of technical difficulty appears higher for LST-NG than for LST-G lesions, as shown by the lower dissection speed and higher perforation rate. ESD for LST-NG should probably be performed by those with significant experience of colorectal ESD.
A
bstract
We report a new measurement of the
e
+
e
−
→
ϒ(
nS
)
π
+
π
−
(
n
= 1
,
2
,
3) cross sections at energies from 10
.
52 to 11
.
02 GeV using data collected with the Belle detector at the KEKB ...asymmetric-energy
e
+
e
−
collider. We observe a new structure in the energy dependence of the cross sections; if described by a Breit-Wigner function its mass and width are found to be
M
=
10752.7
±
5.9
−
1.1
+
0.7
MeV
/
c
2
and
Γ
=
35.5
−
11.3
−
3.3
+
17.6
+
3.9
MeV, where the first error is statistical and the second is systematic. The global significance of the new structure including systematic uncertainty is 5.2 standard deviations. We also find evidence for the
e
+
e
−
→
ϒ (1
S
)
π
+
π
−
process at the energy 10
.
52 GeV, which is below the
B
B
¯
threshold.
Observation of an Excited Ω^{-} Baryon Adachi, I; Ahn, J K; Al Said, S ...
Physical review letters,
2018-Aug-03, Letnik:
121, Številka:
5
Journal Article
Recenzirano
Odprti dostop
Using data recorded with the Belle detector, we observe a new excited hyperon, an Ω^{*-} candidate decaying into Ξ^{0}K^{-} and Ξ^{-}K_{S}^{0} with a mass of 2012.4±0.7(stat)±0.6(syst) MeV/c^{2} and ...a width of Γ=6.4_{-2.0}^{+2.5}(stat)±1.6(syst) MeV. The Ω^{*-} is seen primarily in ϒ(1S),ϒ(2S), and ϒ(3S) decays.
Aliment Pharmacol Ther 2010; 32: 908–915
Summary
Background Endoscopic submucosal dissection (ESD) using short needle knives is safe and effective, but bleeding is a problem due to low haemostatic ...capability.
Aim To assess the performance of a novel ball‐tipped needle knife (Flush knife‐BT) for ESD with particular emphasis on haemostasis.
Methods A case–control study to compare the performance for ESD of 30 pairs of consecutive early gastrointestinal lesions (oesophagus: 12, stomach: 32, colorectum: 16) with standard Flush knife (F) vs. Flush knife‐BT (BT). Primary outcome was efficacy of intraprocedure haemostasis. Secondary outcomes included procedure time, procedure speed (dividing procedure time into the area of resected specimen), en bloc resection rate and recurrence rate.
Results Median intraoperative bleeding points and bleeding points requiring haemostatic forceps were smaller in the BT group than in the F group (4 vs. 8, P < 0.0001, 0 vs. 3, P < 0.0001). There was no difference between groups for procedure time; however, procedure speed was shorter in the BT group (P = 0.0078). En bloc and en bloc R0 resection rates were 100%, with no perforation or post‐operative bleeding. No recurrence was observed in either group at follow‐up 1 year postprocedure.
Conclusions Ball‐tipped Flush knife (Flush knife‐BT) appears to improve haemostatic efficacy and dissection speed compared with standard Flush knife.