A motion artefact is a kind of noise that exists widely in wearable electrocardiogram (ECG) monitoring. Reducing motion artefact is challenging in ECG signal preprocessing because the spectrum of ...motion artefact usually overlaps with the very important spectral components of the ECG signal. In this paper, the performance of the finite impulse response (FIR) filter, infinite impulse response (IIR) filter, moving average filter, moving median filter, wavelet transform, empirical mode decomposition, and adaptive filter in motion artefact reduction is studied and compared. The results of this study demonstrate that the adaptive filter performs better than other denoising methods, especially in dealing with the abnormal ECG signal which is measured from a patient with heart disease. In the implementation of adaptive motion artefact reduction, the results show that the use of the impedance pneumography signal as the reference input signal for the adaptive filter can effectively reduce the motion artefact in the ECG signal.
Wearable sensors have great potential uses in personal health monitoring systems, in which textile-based electrodes are particularly useful because they are comfortable to wear and are skin and ...environmentally friendly. In this paper, a hybrid textile electrode for electrocardiogram (ECG) measurement and motion tracking was introduced. The hybrid textile electrode consists of two parts: A textile electrode for ECG monitoring, and a motion sensor for patient activity tracking. In designing the textile electrodes, their performance in ECG measurement was investigated. Two main influencing factors on the skin-electrode impedance of the electrodes were found: Textile material properties, and electrode sizes. The optimum textile electrode was silver plated, made of a high stitch density weft knitted conductive fabric and its size was 20 mm × 40 mm. A flexible motion sensor circuit was designed and integrated within the textile electrode. Systematic measurements were performed, and results have shown that the hybrid textile electrode is capable of recording ECG and motion signals synchronously, and is suitable for ambulatory ECG measurement and motion tracking applications.
In this review, an attempt was made to summarize some of the recent developments in the spinnability of purified collagen. Due to the excellent biological properties of this biopolymer, it is often ...chosen among other biomimetic materials for processing into fibrous assemblies. During the last two decades, the challenges associated with regenerated collagen fibers comprising inability to achieve sufficient tensile strength, reproducibility and failure to replicate the internal fibrillar structure, which are due to the lost properties from hierarchical structure consistent with collagen in native tissues, have been considered using the common spinning and the modification methods. Among the common spinning methods, dry spinning and wet spinning result in well-defined fibrous blocks with relatively high fiber diameters and alignment, while the ability of the electrospinning to fabricate custom-built nanofibers from collagen-based composites may be the main reason that made it the most applied method to mimic the structure of the collagen in native tissues. In this review, the modification and spinning methods, used for forming collagen fibers, were summarized and their strategy to achieve the modified and reinforced collagen fiber was studied.
Novel Smart Textiles Stylios, George K
Materials,
02/2020, Letnik:
13, Številka:
4
Journal Article
Recenzirano
Odprti dostop
The sensing/adapting/responding, multifunctionality, low energy, small size and weight, ease of forming, and low-cost attributes of SMART textiles and their multidisciplinary scope offer numerous end ...uses in medical, sports and fitness, military, fashion, automotive, aerospace, built environment, and energy industries. The research and development for these new and high-value materials crosses scientific boundaries, redefines material science design and engineering, and enhances quality of life and our environment. "Novel SMART Textiles" is a focused special issue that reports the latest research of this field and facilitates dissemination, networking, discussion, and debate.
In this work, Eucommia ulmoides leaf extract (EUOLstabilized silver nanoparticles (EUOL@AgNPs) incorporated sulfonated polyether sulfone (SPES)/polyethersulfone (PES) electrospun nanofiber membranes ...(SP ENMs) were prepared by electrospinning, and they were studied for the removal of lead (Pb(II)) and cadmium (Cd(II)) ions from aqueous solutions. The SP ENMs with various EUOL@AgNPs loadings were characterized by X-ray diffraction (XRD), Fourier transform infrared (FTIR) spectroscope, thermo-gravimetric analysis (TGA), scanning electron microscopy (SEM), transmission electron microscopy (TEM), and contact angle (CA) measurements. The adsorption studies showed that the adsorption of Cd(II) and Pb(II) was rapid, achieved equilibrium within 40 min and 60 min, respectively and fitted with non-linear pseudo-second-order (PSO) kinetics model. For Cd(II) and Pb(II), the Freundlich model described the adsorption isotherm better than the Langmuir isotherm model. The maximum adsorption capacity for Cd(II) and Pb(II) was 625 and 370.37 mg g
respectively at neutral pH. Coexisting anions of fluoride, chloride, and nitrate had a negligible influence on Cd(II) removal than the Pb(II). On the other hand, the presence of silicate and phosphate considerably affected Cd(II) and Pb(II) adsorption. The recyclability, regeneration, and reusability of the fabricated EUOL@AgNPs-SP ENMs were studied and they retained their high adsorption capacity up to five cycles. The DFT measurements revealed that SP-5 ENMs exhibited the highest adsorption selectivity for Cd(II) and the measured binding energies for Cd(II), Pb(II), are 219.35 and 206.26 kcal mol
, respectively. The developed ENM adsorbent may find application for the removal of heavy metals from water.
Noise is a common problem in wearable electrocardiogram (ECG) monitoring systems because the presence of noise can corrupt the ECG waveform causing inaccurate signal interpretation. By comparison ...with electromagnetic interference and its minimization, the reduction of motion artifact is more difficult and challenging because its time-frequency characteristics are unpredictable. Based on the characteristics of motion artifacts, this work uses adaptive filtering, a specially designed ECG device, and an Impedance Pneumography (IP) data acquisition system to combat motion artifacts. The newly designed ECG-IP acquisition system maximizes signal correlation by measuring both ECG and IP signals simultaneously using the same pair of electrodes. Signal comparison investigations between ECG and IP signals under five different body motions were carried out, and the Pearson Correlation Coefficient |r| was higher than 0.6 in all cases, indicating a good correlation. To optimize the performance of adaptive motion artifact reduction, the IP signal was filtered to a 5 Hz low-pass filter and then fed into a Recursive Least Squares (RLS) adaptive filter as a reference input signal. The performance of the proposed motion artifact reduction method was evaluated subjectively and objectively, and the results proved that the method could suppress the motion artifacts and achieve minimal distortion to the denoised ECG signal.
Editorial – Textile modelling Stylios, George K
International journal of clothing science and technology,
11/2021, Letnik:
33, Številka:
5
Journal Article
A new SMART fabric concept is reported in which visual changes of the material are designed to influence different human emotions. This is achieved by developing a novel electrochromic composite ...yarn, knitted into pattern-changing fabrics, which has high response in temperature change and uniform contrast. The influence of these pattern-changing effects on the response of the human visual brain is investigated further by using event-related potential (ERP). Four SMART pattern-changing fabric pairs were used in this experiment. Each fabric presents two patterns interactively with different, but complementary or opposing, pattern attributes. 20 participants took part in the experiment, in which they were exposed to the patterns, while their visual brain activities were recorded. Comparisons of the three prominent ERP components; P1, N1, and P2 that correspond to the two patterns of each fabric have shown significant differences in the latency and amplitude of these components. These differences show that patterns and pattern-changing cause different visual impacts and that these changes influence our level of attention and processing effort. The study concludes that with the pattern changing ability of these thermochromic hybrid materials we can create designs with attributes that can directly manipulate user emotions, which we like to call 'psychotextiles'. Our study also poses much wider questions of our image processing process in relation to design and art.