The extension of the cosmic-ray spectrum beyond 1 petaelectronvolt (PeV; 10
electronvolts) indicates the existence of the so-called PeVatrons-cosmic-ray factories that accelerate particles to PeV ...energies. We need to locate and identify such objects to find the origin of Galactic cosmic rays
. The principal signature of both electron and proton PeVatrons is ultrahigh-energy (exceeding 100 TeV) γ radiation. Evidence of the presence of a proton PeVatron has been found in the Galactic Centre, according to the detection of a hard-spectrum radiation extending to 0.04 PeV (ref.
). Although γ-rays with energies slightly higher than 0.1 PeV have been reported from a few objects in the Galactic plane
, unbiased identification and in-depth exploration of PeVatrons requires detection of γ-rays with energies well above 0.1 PeV. Here we report the detection of more than 530 photons at energies above 100 teraelectronvolts and up to 1.4 PeV from 12 ultrahigh-energy γ-ray sources with a statistical significance greater than seven standard deviations. Despite having several potential counterparts in their proximity, including pulsar wind nebulae, supernova remnants and star-forming regions, the PeVatrons responsible for the ultrahigh-energy γ-rays have not yet been firmly localized and identified (except for the Crab Nebula), leaving open the origin of these extreme accelerators.
Mergers of neutron stars are known to be associated with short γ-ray bursts
. If the neutron-star equation of state is sufficiently stiff (that is, the pressure increases sharply as the density ...increases), at least some such mergers will leave behind a supramassive or even a stable neutron star that spins rapidly with a strong magnetic field
(that is, a magnetar). Such a magnetar signature may have been observed in the form of the X-ray plateau that follows up to half of observed short γ-ray bursts
. However, it has been expected that some X-ray transients powered by binary neutron-star mergers may not be associated with a short γ-ray burst
. A fast X-ray transient (CDF-S XT1) was recently found to be associated with a faint host galaxy, the redshift of which is unknown
. Its X-ray and host-galaxy properties allow several possible explanations including a short γ-ray burst seen off-axis, a low-luminosity γ-ray burst at high redshift, or a tidal disruption event involving an intermediate-mass black hole and a white dwarf
. Here we report a second X-ray transient, CDF-S XT2, that is associated with a galaxy at redshift z = 0.738 (ref.
). The measured light curve is fully consistent with the X-ray transient being powered by a millisecond magnetar. More intriguingly, CDF-S XT2 lies in the outskirts of its star-forming host galaxy with a moderate offset from the galaxy centre, as short γ-ray bursts often do
. The estimated event-rate density of similar X-ray transients, when corrected to the local value, is consistent with the event-rate density of binary neutron-star mergers that is robustly inferred from the detection of the gravitational-wave event GW170817.
ABSTRACT
High time resolution and accuracy are of critical importance in the studies of timing analysis and time delay localization of gamma-ray bursts (GRBs), soft gamma-ray repeaters (SGRs) and ...pulsars. The Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) consisting of two micro-satellites, GECAM-A and GECAM-B, launched on 2020 December 10, is aimed at monitoring and locating X-ray and GRBs all over the sky. To achieve its scientific goals, GECAM is designed to have the highest time resolution (0.1 $\mu {\rm s}$) among all GRB detectors ever flown. Here, we make a comprehensive time calibration campaign including both on-ground and on-orbit tests to derive not only the relative time accuracy of GECAM satellites and detectors, but also the absolute time accuracy of GECAM-B. Using the on-ground calibration with a $\rm ^{22}Na$ radioactive source, we find that the relative time accuracy between GECAM-A and GECAM-B is about 0.15 $\mu {\rm s}$ (1σ). To measure the relative time accuracy between all detectors of a single GECAM satellite, cosmic-ray events detected on orbit are utilized since they could produce many secondary particles simultaneously record by multiple detectors. We find that the relative time accuracy among all detectors onboard GECAM-B is about 0.12 $\mu {\rm s}$ (1σ). Finally, we use the novel Li-CCF method to perform the absolute time calibration with Crab pulsar and SGR J1935+2154, both of which were jointly observed by GECAM-B and Fermi/GBM, and obtain that the time difference between GECAM-B and Fermi/GBM is 3.06 ± 6.04 $\mu {\rm s}$ (1σ).
We report a study of the processes of e^{+}e^{-}→K^{+}D_{s}^{-}D^{*0} and K^{+}D_{s}^{*-}D^{0} based on e^{+}e^{-} annihilation samples collected with the BESIII detector operating at BEPCII at five ...center-of-mass energies ranging from 4.628 to 4.698 GeV with a total integrated luminosity of 3.7 fb^{-1}. An excess of events over the known contributions of the conventional charmed mesons is observed near the D_{s}^{-}D^{*0} and D_{s}^{*-}D^{0} mass thresholds in the K^{+} recoil-mass spectrum for events collected at sqrts=4.681 GeV. The structure matches a mass-dependent-width Breit-Wigner line shape, whose pole mass and width are determined as (3982.5_{-2.6}^{+1.8}±2.1) MeV/c^{2} and (12.8_{-4.4}^{+5.3}±3.0) MeV, respectively. The first uncertainties are statistical and the second are systematic. The significance of the resonance hypothesis is estimated to be 5.3 σ over the contributions only from the conventional charmed mesons. This is the first candidate for a charged hidden-charm tetraquark with strangeness, decaying into D_{s}^{-}D^{*0} and D_{s}^{*-}D^{0}. However, the properties of the excess need further exploration with more statistics.
The exclusive process e+e−→ΛΛ¯, with Λ→pπ− and Λ¯→p¯π+, has been studied at s=2.396 GeV for measurement of the timelike Λ electric and magnetic form factors, GE and GM. A data sample, corresponding ...to an integrated luminosity of 66.9 pb−1, was collected with the BESIII detector for this purpose. A multidimensional analysis with a complete decomposition of the spin structure of the reaction enables a determination of the modulus of the ratio R=|GE/GM| and, for the first time for any baryon, the relative phase ΔΦ=ΦE−ΦM. The resulting values are R=0.96±0.14(stat)±0.02(syst) and ΔΦ=37°±12°(stat)±6°(syst), respectively. These are obtained using the recently established and most precise value of the asymmetry parameter αΛ=0.750±0.010 measured by BESIII. In addition, the cross section is measured with unprecedented precision to be σ=118.7±5.3(stat)±5.1(syst) pb, which corresponds to an effective form factor of |G|=0.123±0.003(stat)±0.003(syst). The contribution from two-photon exchange is found to be negligible. Our result enables the first complete determination of baryon timelike electromagnetic form factors.
Using a total of 11.0 fb^{-1} of e^{+}e^{-} collision data with center-of-mass energies between 4.009 and 4.6 GeV and collected with the BESIII detector at BEPCII, we measure fifteen exclusive cross ...sections and effective form factors for the process e^{+}e^{-}→Ξ^{-}Ξover ¯^{+} by means of a single baryon-tag method. After performing a fit to the dressed cross section of e^{+}e^{-}→Ξ^{-}Ξover ¯^{+}, no significant ψ(4230) or ψ(4260) resonance is observed in the Ξ^{-}Ξover ¯^{+} final states, and upper limits at the 90% confidence level on Γ_{ee}B for the processes ψ(4230)/ψ(4260)→Ξ^{-}Ξover ¯^{+} are determined. In addition, an excited Ξ baryon at 1820 MeV/c^{2} is observed with a statistical significance of 6.2-6.5σ by including the systematic uncertainty, and the mass and width are measured to be M=(1825.5±4.7±4.7) MeV/c^{2} and Γ=(17.0±15.0±7.9) MeV, which confirms the existence of the J^{P}=3/2^{-} state Ξ(1820).
We study the e^{+}e^{-}→γωJ/ψ process using 11.6 fb^{-1} e^{+}e^{-} annihilation data taken at center-of-mass energies from sqrts=4.008 GeV to 4.600 GeV with the BESIII detector at the BEPCII ...storage ring. The X(3872) resonance is observed for the first time in the ωJ/ψ system with a significance of more than 5σ. The relative decay ratio of X(3872)→ωJ/ψ and π^{+}π^{-}J/ψ is measured to be R=1.6_{-0.3}^{+0.4}±0.2, where the first uncertainty is statistical and the second systematic (the same hereafter). The sqrts-dependent cross section of e^{+}e^{-}→γX(3872) is also measured and investigated, and it can be described by a single Breit-Wigner resonance, referred to as the Y(4200), with a mass of 4200.6_{-13.3}^{+7.9}±3.0 MeV/c^{2} and a width of 115_{-26}^{+38}±12 MeV. In addition, to describe the ωJ/ψ mass distribution above 3.9 GeV/c^{2}, we need at least one additional Breit-Wigner resonance, labeled as X(3915), in the fit. The mass and width of the X(3915) are determined. The resonant parameters of the X(3915) agree with those of the Y(3940) in B→KωJ/ψ and of the X(3915) in γγ→ωJ/ψ observed by the Belle and BABAR experiments within errors.
High-energy photons from the Crab Nebula
The Crab Nebula contains a pulsar that excites the surrounding gas to emit high-energy radiation. The combination of the pulsar's youth and nearby location ...makes the nebula the brightest gamma-ray source in the sky. The LHAASO Collaboration report observations of this source at energies of tera– to peta–electron volts, extending the spectrum of this prototypical object. They combine these data with observations at lower energies to model the physics of the emission process. The multiwave-length data can be explained by a combination of synchrotron radiation and inverse Compton scattering.
Science
, abg5137, this issue p.
425
Detection of the Crab Nebula at peta–electron volt energies constrains the gamma-ray emission mechanism.
The Crab Nebula is a bright source of gamma rays powered by the Crab Pulsar’s rotational energy through the formation and termination of a relativistic electron-positron wind. We report the detection of gamma rays from this source with energies from 5 × 10
−4
to 1.1 peta–electron volts with a spectrum showing gradual steepening over three energy decades. The ultrahigh-energy photons imply the presence of a peta–electron volt electron accelerator (a pevatron) in the nebula, with an acceleration rate exceeding 15% of the theoretical limit. We constrain the pevatron’s size between 0.025 and 0.1 parsecs and the magnetic field to ≈110 microgauss. The production rate of peta–electron volt electrons, 2.5 × 10
36
ergs per second, constitutes 0.5% of the pulsar spin-down luminosity, although we cannot exclude a contribution of peta–electron volt protons to the production of the highest-energy gamma rays.
Summary
We investigated the secular trends of the incidence and hospitalization cost of hip fracture in Tangshan, China. The incidence of hip fracture and the hospitalization cost were both ...increasing during the observation period.
Introduction
The present study aimed to determine sex-, age-, and fracture type-specific incidence and annual changes in hip fractures in Tangshan, China, between 2007 and 2018.
Methods
We analyzed annual hip fracture incidence using urban hospital data during 2007–2018 and calculated incidence rate/100,000 person years in each age group and sex. We assessed annual changes in incidence among people aged >60 years using linear-by-linear association tests and evaluated hospitalization costs with the Kruskal–Wallis test.
Results
During the study period, we observed an increasing proportion of hip fractures in people >60 years old from 14.2 to 22.79%. Crude hip fracture incidence increased markedly from 140.87 to 306.56/100,000 in women (
p
< 0.01) and from 124.83 to 167.19/100,000 in men (
p
< 0.01) in the age group >60 years. Type-specific analysis indicated significantly increased trends in incidence of cervical and trochanteric fractures among women and cervical fracture among men (
p
< 0.01). In people aged 36–60 years, the trend of hip fracture increased significantly in both sexes. The total and cervical-to-trochanteric ratio in men increased, with significant upward trends (
p
< 0.01). The proportion of cervical fracture was higher than that for trochanteric fracture in women, with stable levels from 2007 to 2018. Hospitalization costs for cervical and trochanteric fractures increased by 51.91% and 53.20%, respectively, during 2011–2018.
Conclusion
Tangshan will have an increasing burden on health care resources attributable to a considerable rise in hip fracture incidence and the older population. Further investigation of risk factors and subsequent implementation of effective measures to prevent hip fracture are needed.