This paper summarizes emerging practice and research issues in the health insurance industry. We provide an industry overview, epitomize business analytics applications, and outline current and ...emerging problems of interest to key stakeholders and researchers in information systems, operations management, and healthcare management. Specifically, we focus on three areas of research that are of importance to the health insurance industry as well as the healthcare system: (i) management and evaluation of intervention programs, (ii) creation of effective provider networks, and (iii) emerging issues such as the impact of a pandemic, patient communication and steering, and technological innovations in health care. We lay out brief details of how each of these problems can be formulated, where the data can be acquired (public and/or proprietary data sets), and provide guidance for solving them. For several of these problems, we provide models that span causal modeling, predictive modeling, and prescriptive modeling.
BACKGROUND:Residual postoperative paralysis from nondepolarizing neuromuscular blocking agents (NMBAs) is a known problem. This paralysis has been associated with impaired respiratory function, but ...the clinical significance remains unclear. The aims of this analysis were two-fold(1) to investigate if intermediate-acting NMBA use during surgery is associated with postoperative pneumonia and (2) to investigate if nonreversal of NMBAs is associated with postoperative pneumonia.
METHODS:Surgical cases (n = 13,100) from the Vanderbilt University Medical Center National Surgical Quality Improvement Program database who received general anesthesia were included. The authors compared 1,455 surgical cases who received an intermediate-acting nondepolarizing NMBA to 1,455 propensity score–matched cases who did not and 1,320 surgical cases who received an NMBA and reversal with neostigmine to 1,320 propensity score–matched cases who did not receive reversal. Postoperative pneumonia incidence rate ratios (IRRs) and bootstrapped 95% CIs were calculated.
RESULTS:Patients receiving an NMBA had a higher absolute incidence rate of postoperative pneumonia (9.00 vs. 5.22 per 10,000 person-days at risk), and the IRR was statistically significant (1.79; 95% bootstrapped CI, 1.08 to 3.07). Among surgical cases who received an NMBA, cases who were not reversed were 2.26 times as likely to develop pneumonia after surgery compared to cases who received reversal with neostigmine (IRR, 2.26; 95% bootstrapped CI, 1.65 to 3.03).
CONCLUSIONS:Intraoperative use of intermediate nondepolarizing NMBAs is associated with developing pneumonia after surgery. Among patients who receive these agents, nonreversal is associated with an increased risk of postoperative pneumonia.
The development of novel multiple-element transmit-receive arrays is an essential factor for improving B.sub.1 .sup.+ field homogeneity in cardiac MRI at ultra-high magnetic field strength (B.sub.0 > ...= 7.0T). One of the key steps in the design and fine-tuning of such arrays during the development process is finding the default driving phases for individual coil elements providing the best possible homogeneity of the combined B.sub.1 .sup.+ -field that is achievable without (or before) subject-specific B.sub.1 .sup.+ -adjustment in the scanner. This task is often solved by time-consuming (brute-force) or by limited efficiency optimization methods. In this work, we propose a robust technique to find phase vectors providing optimization of the B.sub.1 -homogeneity in the default setup of multiple-element transceiver arrays. The key point of the described method is the pre-selection of starting vectors for the iterative solver-based search to maximize the probability of finding a global extremum for a cost function optimizing the homogeneity of a shaped B.sub.1 .sup.+ -field. This strategy allows for (i) drastic reduction of the computation time in comparison to a brute-force method and (ii) finding phase vectors providing a combined B.sub.1 .sup.+ -field with homogeneity characteristics superior to the one provided by the random-multi-start optimization approach. The method was efficiently used for optimizing the default phase settings in the in-house-built 8Tx/16Rx arrays designed for cMRI in pigs at 7T.
A novel mono-surface antisymmetric 16-element transmit/receive (Tx/Rx) coil array was designed, simulated, constructed, and tested for cardiac magnetic resonance imaging (cMRI) in pigs at 7 T. The ...cardiac array comprised of a mono-surface 16-loops with two central elements arranged anti-symmetrically and flanked by seven elements on either side. The array was configured for parallel transmit (pTx) mode to have an eight channel transmit and 16-channel receive (8Tx/16Rx) coil array. Electromagnetic (EM) simulations, bench-top measurements, phantom, and MRI experiments with two pig cadavers (68 and 46 kg) were performed. Finally, the coil was used in pilot in-vivo measurements with a 60 kg pig. Flip angle (FA), geometry factor (g-factor), signal-to-noise ratio (SNR) maps, and high-resolution cardiac images were acquired with an in-plane resolution of 0.6 mm × 0.6 mm (in-vivo) and 0.3 mm × 0.3 mm (ex-vivo). The mean g-factor over the heart was 1.26 (R = 6). Static phase Formula: see text shimming in a pig body phantom with the optimal phase vectors makes possible to improve the Formula: see text homogeneity by factor > 2 and transmit efficiency by factor > 3 compared to zero phases (before RF shimming). Parallel imaging performed in the in-vivo measurements demonstrated well preserved diagnostic quality of the resulting images at acceleration factors up to R = 6. The described hardware design can be adapted for arrays optimized for animals and humans with a larger number of elements (32-64) while maintaining good decoupling for various MRI applications at UHF (e.g., cardiac, head, and spine).
BACKGROUND:Whether anesthesia care transitions and provision of short breaks affect patient outcomes remains unclear.
METHODS:The authors determined the number of anesthesia handovers and breaks ...during each case for adults admitted between 2005 and 2014, along with age, sex, race, American Society of Anesthesiologists physical status, start time and duration of surgery, and diagnosis and procedure codes. The authors defined a collapsed composite of in-hospital mortality and major morbidities based on primary and secondary diagnoses. The relationship between the total number of anesthesia handovers during a case and the collapsed composite outcome was assessed with a multivariable logistic regression. The relationship between the total number of anesthesia handovers during a case and the components of the composite outcome was assessed using multivariate generalized estimating equation methods. Additionally, the authors analyzed major complications and/or death within 30 days of surgery based on the American College of Surgeons National Surgical Quality Improvement Program–defined events.
RESULTS:A total of 140,754 anesthetics were identified for the primary analysis. The number of anesthesia handovers was not found to be associated (P = 0.19) with increased odds of postoperative mortality and serious complications, as measured by the collapsed composite, with odds ratio for a one unit increase in handovers of 0.957; 95% CI, 0.895 to 1.022, when controlled for potential confounding variables. A total of 8,404 anesthetics were identified for the NSQIP analysis (collapsed composite odds ratio, 0.868; 95% CI, 0.718 to 1.049 for handovers).
CONCLUSIONS:In the analysis of intraoperative handovers, anesthesia care transitions were not associated with an increased risk of postoperative adverse outcomes.
Cardiac magnetic resonance (CMR) at ultrahigh field (UHF) offers the potential of high resolution and fast image acquisition. Both technical and physiological challenges associated with CMR at 7T ...require specific hardware and pulse sequences. This study aimed to assess the current status and existing, publicly available technology regarding the potential of a clinical application of 7T CMR. Using a 7T MRI scanner and a commercially available radiofrequency coil, a total of 84 CMR examinations on 72 healthy volunteers (32 males, age 19-70 years, weight 50-103 kg) were obtained. Both electrocardiographic and acoustic triggering were employed. The data were analyzed regarding the diagnostic image quality and the influence of patient and hardware dependent factors. 50 complete short axis stacks and 35 four chamber CINE views were used for left ventricular (LV) and right ventricular (RV), mono-planar LV function, and RV fractional area change (FAC). Twenty-seven data sets included aortic flow measurements that were used to calculate stroke volumes. Subjective acceptance was obtained from all volunteers with a standardized questionnaire. Functional analysis showed good functions of LV (mean EF 56%), RV (mean EF 59%) and RV FAC (mean FAC 52%). Flow measurements showed congruent results with both ECG and ACT triggering. No significant influence of experimental parameters on the image quality of the LV was detected. Small fractions of 5.4% of LV and 2.5% of RV segments showed a non-diagnostic image quality. The nominal flip angle significantly influenced the RV image quality. The results demonstrate that already now a commercially available 7T MRI system, without major methods developments, allows for a solid morphological and functional analysis similar to the clinically established CMR routine approach. This opens the door towards combing routine CMR in patients with development of advanced 7T technology.
Cardiac magnetic resonance (CMR) imaging allows precise non-invasive quantification of cardiac function. It requires reliable image segmentation for myocardial tissue. Clinically used software ...usually offers automatic approaches for this step. These are, however, designed for segmentation of human images obtained at clinical field strengths. They reach their limits when applied to preclinical data and ultrahigh field strength (such as CMR of pigs at 7 T). In our study, eleven animals (seven with myocardial infarction) underwent four CMR scans each. Short-axis cine stacks were acquired and used for functional cardiac analysis. End-systolic and end-diastolic images were labelled manually by two observers and inter- and intra-observer variability were assessed. Aiming to make the functional analysis faster and more reproducible, an established deep learning (DL) model for myocardial segmentation in humans was re-trained using our preclinical 7 T data (n = 772 images and labels). We then tested the model on n = 288 images. Excellent agreement in parameters of cardiac function was found between manual and DL segmentation: For ejection fraction (EF) we achieved a Pearson's r of 0.95, an Intraclass correlation coefficient (ICC) of 0.97, and a Coefficient of variability (CoV) of 6.6%. Dice scores were 0.88 for the left ventricle and 0.84 for the myocardium.
Purpose of this work was to assess feasibility of cardiac diffusion tensor imaging (cDTI) at 7 T in a set of healthy, unfixed, porcine hearts using various parallel imaging acceleration factors and ...to compare SNR and derived cDTI metrics to a reference measured at 3 T. Magnetic resonance imaging was performed on 7T and 3T whole body systems using a spin echo diffusion encoding sequence with echo planar imaging readout. Five reference (b = 0 s/mm2) images and 30 diffusion directions (b = 700 s/mm2) were acquired at both 7 T and 3 T using a GRAPPA acceleration factor R = 1. Scans at 7 T were repeated using R = 2, R = 3, and R = 4. SNR evaluation was based on 30 reference (b = 0 s/mm2) images of 30 slices of the left ventricle and cardiac DTI metrics were compared within AHA segmentation. The number of hearts scanned at 7 T and 3 T was n = 11. No statistically significant differences were found for evaluated helix angle, secondary eigenvector angle, fractional anisotropy and apparent diffusion coefficient at the different field strengths, given sufficiently high SNR and geometrically undistorted images. R≥3 was needed to reduce susceptibility induced geometric distortions to an acceptable amount. On average SNR in myocardium of the left ventricle was increased from 29±3 to 44±6 in the reference image (b = 0 s/mm2) when switching from 3 T to 7 T. Our study demonstrates that high resolution, ex vivo cDTI is feasible at 7 T using commercial hardware.
Background
To investigate the effects of B
1
-shimming and radiofrequency (RF) parallel transmission (pTX) on the visualization and quantification of the degree of stenosis in a coronary artery ...phantom using 7 Tesla (7 T) magnetic resonance imaging (MRI).
Methods
Stenosis phantoms with different grades of stenosis (0%, 20%, 40%, 60%, 80%, and 100%; 5 mm inner vessel diameter) were produced using 3D printing (clear resin). Phantoms were imaged with four different concentrations of diluted Gd-DOTA representing established arterial concentrations after intravenous injection in humans. Samples were centrally positioned in a thorax phantom of 30 cm diameter filled with a custom-made liquid featuring dielectric properties of muscle tissue. MRI was performed on a 7 T whole-body system. 2D-gradient-echo sequences were acquired with an 8-channel transmit 16-channel receive (8 Tx / 16 Rx) cardiac array prototype coil with and without pTX mode. Measurements were compared to those obtained with identical scan parameters using a commercially available 1 Tx / 16 Rx single transmit coil (sTX). To assess reproducibility, measurements (
n
= 15) were repeated at different horizontal angles with respect to the B
0
-field.
Results
B
1
-shimming and pTX markedly improved flip angle homogeneity across the thorax phantom yielding a distinctly increased signal-to-noise ratio (SNR) averaged over a whole slice relative to non-manipulated RF fields. Images without B
1
-shimming showed shading artifacts due to local B
1
+
-field inhomogeneities, which hampered stenosis quantification in severe cases. In contrast, B
1
-shimming and pTX provided superior image homogeneity. Compared with a conventional sTX coil higher grade stenoses (60% and 80%) were graded significantly (p<0.01) more precise. Mild to moderate grade stenoses did not show significant differences. Overall, SNR was distinctly higher with B
1
-shimming and pTX than with the conventional sTX coil (inside the stenosis phantoms 14%, outside the phantoms 32%). Both full and half concentration (10.2 mM and 5.1 mM) of a conventional Gd-DOTA dose for humans were equally suitable for stenosis evaluation in this phantom study.
Conclusions
B
1
-shimming and pTX at 7 T can distinctly improve image homogeneity and therefore provide considerably more accurate MR image analysis, which is beneficial for imaging of small vessel structures.
The purpose of the study is labor saving, productivity gain of work and ball screws quality design pursuant to the use in numerical control machines. The article is devoted to the problem of ...automation of the designing of ball screws with return ports. These ball screws are an important element of the mechatronic modules of numerically controlled machines, as they affect the accuracy of linear displacement. Research methods: system-oriented analysis, structural analysis, methods of functional and object-matching programming, simulation. The novelty of the work: a method of three-dimensional parametric simulation of nuts of ball screws and a computation algorithm for a ball screw based on the synthesis of well-known techniques, has been developed. Research results: a software product consisting of modules that together automate the design process of nuts, screws, rigid supports, tilting saddles and ball screw coupling elements, has been developed. Conclusions: the developed methods for calculation of basic ball screw parameters can be used as the algorithmic basis of software products. Since the process for designing ball screw nuts with return ports has been automated, there are grounds for developing automation methods for other types of nuts.