Catheter ablation for atrial fibrillation (AF) treatment provides effective and durable pulmonary vein isolation (PVI) and is associated with encouraging clinical outcome. A novel CF sensing ...temperature-controlled radiofrequency (RF) ablation catheter allows for very high-power short-duration (vHP-SD, 90 W/4 s) ablation aiming a potentially safer, more effective and faster ablation. We thought to evaluate preliminary safety and efficacy of vHP-SD ablation for PVI utilizing a novel vHP-SD catheter. The data was compared to conventional power-controlled ablation index (AI) guided PVI utilizing conventional contact force (CF) sensing catheters.
Fifty-six patients with paroxysmal or persistent AF were prospectively enrolled in this study. Twenty-eight consecutive patients underwent vHP-SD based PVI (vHP-SD group) and were compared to 28 consecutive patients treated with conventional CF-sensing catheters utilizing the AI (control group). All PVs were successfully isolated using vHP-SD. The median RF ablation time for vHP-SD was 338 (IQR 286, 367) seconds vs control 1580 (IQR 1350, 1848) seconds (p < 0.0001), the median procedure duration was vHP-SD 55 (IQR 48–60) minutes vs. control 105 (IQR 92–120) minutes (p < 0.0001). No differences in periprocedural complications were observed.
This preliminary data of the novel vHP-SD ablation mode provides safe and effective PVI. Procedure duration and RF ablation time were substantially shorter in the vHP-SD group in comparison to the control group.
Very high-power short-duration (vHP-SD) radiofrequency (RF) ablation of atrial fibrillation (AF) treatment by pulmonary vein isolation (PVI) aims for safer, more effective and faster procedures. ...Although acute efficacy and safety for PVI was recently shown data on chronic PVI durability is limited. Here chronic PVI durability was evaluated during repeat electrophysiological procedures in patients after initial vHP-SD and conventional RF based PVI.
A total of 25 consecutive patients with repeat left atrial procedures after initial vHP-SD based PVI were included in this study. Twenty-five patients with previous conventional RF based PVI and repeat left atrial procedures served as control (control group).
For index procedures the median RF time was 328 (277, 392) seconds (vHP-SD) and 1470 (1310, 1742) seconds (control); p < 0.001, the median procedure time was 55 (53, 68) minutes (vHP-SD) and 110 (94, 119) (control); p < 0.001). First pass isolation rate was 84 % (vHP-SD) and 88 % (control, p = 0.888). No differences for severe adverse events (vHP-SD: 1/25, 4 % vs. control: 0/25, 0 %; p = 0.676 were detected.
Chronic durability of all PVs was assessed in vHP-SD: 16/25 (64 %) and control: 8/25 (32 %) patients (p = 0.023) and vHP-SD: 81 % and control: 62 % of PVs were found to be isolated (p = 0.003). For right PVs vHP-SD: 84 % vs. control: 60 % of PVs (p < 0.001) and for left PVs vHP-SD: 78 % vs. control: 64 % (p = 0.123) were found to be isolated.
PVI solely utilizing vHP-SD via a very close-protocol provides fast, safe and effective acute PVI. High rates of chronically isolated pulmonary veins have been detected.
Wide antral circumferential ablation (WACA) in comparison to ostial pulmonary vein (PV) isolation (PVI) has been attributed with improved rhythm outcome. We investigated the feasibility, lesion ...formation, and rhythm outcome of WACA-PVI in comparison to ostial-PVI using pulsed field ablation (PFA).
Symptomatic atrial fibrillation (AF) patients (69 years, 67% male; 67% paroxysmal AF) were prospectively enrolled into our single-center registry and underwent first-time ostial-PFA or WACA-PFA,
= 15 each. In all patients, eight pulse trains (2 kV/2.5 s, bipolar, biphasic, 4× basket/flower configuration each) were delivered to each PV. In WACA-PFA, two extra pulse trains in a flower configuration were added to the anterior and posterior antrum of the PVs. For comparison of PFA lesion size, pre- and post-ablation left atrial (LA) voltage maps were acquired using a multipolar spiral catheter together with a three-dimensional electroanatomic mapping system.
WACA-PFA resulted in a significant larger lesion formation than ostial-PFA (45.5 vs. 35.1 cm
,
= 0.001) with bilateral overlapping butterfly shape-like lesions and concomitant posterior LA wall isolation in 73% of patients. This was not associated with increased procedure time, sedation dosage, or exposure to radiation. One-year freedom from AF recurrence was numerically higher after WACA-PFA than ostial-PFA (94% vs. 87%) but not statistically significant (
= 0.68). No organized atrial tachycardias (ATs) were observed. Ostial-PFA patients more often underwent re-ablation due to recurrent AF episodes.
WACA-PFA is feasible and resulted in significantly wider lesion sets than ostial-PFA. Concomitant posterior LA wall isolation occurred as an epiphenomenon in the majority of patients. The WACA approach was associated with neither increased procedure and fluoroscopy times nor statistically significant differences in 1-year rhythm outcome. ATs were absent.
We sought to assess the efficacy, safety and short-term clinical outcome of very high-power short-duration (vHP-SD) radiofrequency (RF) catheter ablation for the treatment of idiopathic PVCs ...originating from the cardiac outflow tract (OT).
Power-controlled RF ablation is a widely used technique for the treatment of premature ventricular contractions (PVCs). A novel ablation catheter offers three microelectrodes and six thermocouples at its tip and provides temperature-controlled vHP-SD (90 Watts/4 s,) with the opportunity to switch to moderate-power mode.
In this pilot study, twenty-four consecutive, prospectively enrolled patients underwent PVC ablation utilizing the vHP-SD ablation (study group) and were compared with 24 consecutive patients previously treated with power-controlled ablation (control group). Each group included 12 patients with PVCs originating from the right ventricular OT (RVOT) and 12 patients with PVCs originating from the left ventricular OT (LVOT). The acute endpoint was PVC elimination and was achieved in all patients.
In 16/24 (67%) patients (study group) it was achieved by using vHP-SD only. The median RF delivery time was 52 (interquartile range IQR 16, 156) seconds (study group) and 350 (IQR 240, 442) seconds (control group, p < 0.0001). No difference was observed regarding procedure duration (p = 0.489) as well as 6-months follow-up (p = 0.712). One (4%, study group) and 2 (8%, control group) severe adverse events occured (p = 0.551).
In this study, vHP-SD PVC ablation was similarly effective and safe as compared to conventional power-controlled ablation. The RF time was significantly shorter.
The new European Society of Cardiology (ESC) guidelines on cardiac pacing and cardiac resynchronization therapy were presented together with the new ESC heart failure guidelines at the ESC congress ...in September. The new document includes detailed sections on patient evaluation and clinical assessment, implantation, minimizing complications and patient follow-up. The guidelines have been updated and expanded particularly on the approach to reflex syncope, the indications after transcatheter aortic valve implantation (TAVI) and the perioperative management. The indications for cardiac resynchronization therapy (CRT) are now in line with the simultaneously published ESC heart failure guidelines. New physiological forms of stimulation and leadless pacing are now included in the guidelines.
ZusammenfassungDie neuen Leitlinien der European Society of Cardiology (ESC) zur Herzschrittmacher- und Resynchronisationstherapie wurden im September zeitgleich mit den neuen ...Herzinsuffizienzleitlinien am ESC-Kongress vorgestellt. Das neue Dokument beinhaltet ausführliche Abschnitte von der Patientenevaluation und klinischen Beurteilung über die Implantation und die Minimierung von Komplikationen bis zur Nachsorge. Aktualisiert und ergänzt wurden die Leitlinien dabei insbesondere um das Vorgehen bei Reflexsynkopen, die Indikation nach Transkatheteraortenklappenimplantation (TAVI) sowie das perioperative Management. Die Indikationen zur kardialen Resynchronisationstherapie wurden mit den Herzinsuffizienzleitlinien abgeglichen. Neue physiologische Stimulationsformen sowie der kabellose Schrittmacher wurden in die Leitlinien aufgenommen.
Zusammenfassung
Die neuen Leitlinien der European Society of Cardiology (ESC) zur Herzschrittmacher- und Resynchronisationstherapie wurden im September zeitgleich mit den neuen ...Herzinsuffizienzleitlinien am ESC-Kongress vorgestellt. Das neue Dokument beinhaltet ausführliche Abschnitte von der Patientenevaluation und klinischen Beurteilung über die Implantation und die Minimierung von Komplikationen bis zur Nachsorge. Aktualisiert und ergänzt wurden die Leitlinien dabei insbesondere um das Vorgehen bei Reflexsynkopen, die Indikation nach Transkatheteraortenklappenimplantation (TAVI) sowie das perioperative Management. Die Indikationen zur kardialen Resynchronisationstherapie wurden mit den Herzinsuffizienzleitlinien abgeglichen. Neue physiologische Stimulationsformen sowie der kabellose Schrittmacher wurden in die Leitlinien aufgenommen.
Chylothorax After Heart Surgery in Children Bauer, Juliane Kuster; Hocama, Nathalia; Traub, Anna Clara ...
Pediatric cardiology,
12/2023, Letnik:
44, Številka:
8
Journal Article
Recenzirano
Chylothorax is a consequence of a thoracic duct injury that can occur during surgical procedures in patients with congenital heart disease. It is associated with high rates of morbimortality and ...increased use of clinical and hospital resources. The aim of this study was to evaluate the risk factors, distribution, manifestations, complications, and treatments for chylothorax in patients undergoing cardiac surgery in a tertiary pediatric hospital in southern Brazil. This is a retrospective, quantitative study, in which all medical records (n = 166) of patients with chylothorax after pediatric cardiac surgery between January 2014 and December of 2020 and a matched control group (n = 166) were analyzed. Over the study period, there was an increase in incidence of chylothorax from 4.5% in 2014 to 7.6% in 2020, a trend that has been reported in the literature. After multivariate analysis, the following were identified as risk factors for the diagnosis of chylothorax: genetic syndrome (OR 2.298); prolonged cardiopulmonary bypass time (greater than 120 min) (OR 2.410); fluid overload in the immediate postoperative period (OR 1.110); and SIRS (OR 2.527). Mortality was two times greater (p = 0.021) and there was a higher rate (34.4%) of infection (p < 0.001) in patients who developed chylothorax. In addition, a sensitivity analysis was performed comparing patients with low- and high-output chylothorax (> 20 mL/kg), which confirmed unfavorable outcomes for the latter group. Herein, we show that hemodynamic alterations were important factors for diagnosis. Understanding the risk factors, outcomes, and complications helps early identification and enables the reduction of morbidity and mortality.
Hypotonie nach Katheterablation Keelani, Ahmad; Traub, Anna; Vogler, Julia ...
Herzschrittmachertherapie & Elektrophysiologie,
12/2021, Letnik:
32, Številka:
4
Journal Article
Recenzirano
Zusammenfassung
Eine 80-jährige Patientin mit symptomatischer atrialer Tachykardie wird nach Pulmonalvenenisolation mit Anlage einer anterioren Linie ebenso wie einer endo- und epikardialen ...Mitralisthmuslinie im Aufwachraum kaltschweißig und hypoton. Echokardiographisch konnte ein hämodynamisch relevanter Perikarderguss ausgeschlossen werden. Die Symptomatik der Patientin ist mit der Zeit progredient. Eine seltene Ursache wurde gefunden.