Aim
The purpose of this study is to describe the main chest radiological features (CXR) of COVID-19 and correlate them with clinical outcome.
Materials and methods
This is a retrospective study ...involving patients with clinical-epidemiological suspect of COVID-19 infection, who performed CXRs at the emergency department (ED) of our University Hospital from March 1 to March 31, 2020. All patients performed RT-PCR nasopharyngeal and throat swab, CXR at the ED and clinical-epidemiological data. RT-PCR results were considered the reference standard. The final outcome was expressed as discharged or hospitalized patients into a medicine department or intensive care unit (ICU).
Results
Patients that had a RT-PCR positive for COVID-19 infection were 234 in total: 153 males (65.4%) and 81 females (34.6%), with a mean age of 66.04 years (range 18–97 years). Thirteen CXRs were negative for radiological thoracic involvement (5.6%). The following alterations were more commonly observed: 135 patients with lung consolidations (57.7%), 147 (62.8%) with GGO, 55 (23.5%) with nodules and 156 (66.6%) with reticular–nodular opacities. Patients with consolidations and GGO coexistent in the same radiography were 35.5% of total. Peripheral (57.7%) and lower zone distribution (58.5%) were the most common predominance. Moreover, bilateral involvement (69.2%) was most frequent than unilateral one. Baseline CXR sensitivity in our experience is about 67.1%. The most affected patients were especially males in the age group 60–79 years old (45.95%, of which 71.57% males). RALE score was slightly higher in male than in female patients. ANOVA with Games-Howell post hoc showed significant differences of RALE scores for group 1 vs 3 (
p
< 0.001) and 2 vs 3 (
p
= 0.001). Inter-reader agreement in assigning RALE score was very good (ICC: 0.92—with 95% confidence interval 0.88–0.95).
Conclusion
In COVID-19, CXR shows patchy or diffuse reticular–nodular opacities and consolidation, with basal, peripheral and bilateral predominance. In our experience, baseline CXR had a sensitivity of 68.1%. The RALE score can be used in the emergency setting as a quantitative method of the extent of SARS-CoV-2 pneumonia, correlating with an increased risk of ICU admission.
OBJECTIVEThe aim of this study was to investigate the image quality, radiation dose, and accuracy of virtual noncontrast images and iodine quantification of split-filter dual-energy computed ...tomography (CT) using a single x-ray source in a phantom and patient study.
MATERIALS AND METHODSIn a phantom study, objective image quality and accuracy of iodine quantification were evaluated for the split-filter dual-energy mode using a tin and gold filter. In a patient study, objective image quality and radiation dose were compared in thoracoabdominal CT of 50 patients between the standard single-energy and split-filter dual-energy mode. The radiation dose was estimated by size-specific dose estimate. To evaluate the accuracy of virtual noncontrast imaging, attenuation measurements in the liver, spleen, and muscle were compared between a true noncontrast premonitoring scan and the virtual noncontrast images of the dual-energy scans. Descriptive statistics and the Mann-Whitney U test were used.
RESULTSIn the phantom study, differences between the real and measured iodine concentration ranged from 2.2% to 21.4%. In the patient study, the single-energy and dual-energy protocols resulted in similar image noise (7.4 vs 7.1 HU, respectively; P = 0.43) and parenchymal contrast-to-noise ratio (CNR) values for the liver (29.2 vs 28.5, respectively; P = 0.88). However, the vascular CNR value for the single-energy protocol was significantly higher than for the dual-energy protocol (10.0 vs 7.1, respectively; P = 0.006). The difference in the measured attenuation between the true and the virtual noncontrast images ranged from 3.1 to 6.7 HU. The size-specific dose estimate of the dual-energy protocol was, on average, 17% lower than that of the single-energy protocol (11.7 vs 9.7 mGy, respectively; P = 0.008).
CONCLUSIONSSplit-filter dual-energy compared with single-energy CT results in similar objective image noise in addition to dual-energy capabilities at 17% lower radiation dose. Because of beam hardening, split-filter dual-energy can lead to decreased CNR values of iodinated structures.
Background
The respiratory illness caused by SARS‐CoV‐2 infection continues to present diagnostic challenges. Our 2020 edition of this review showed thoracic (chest) imaging to be sensitive and ...moderately specific in the diagnosis of coronavirus disease 2019 (COVID‐19). In this update, we include new relevant studies, and have removed studies with case‐control designs, and those not intended to be diagnostic test accuracy studies.
Objectives
To evaluate the diagnostic accuracy of thoracic imaging (computed tomography (CT), X‐ray and ultrasound) in people with suspected COVID‐19.
Search methods
We searched the COVID‐19 Living Evidence Database from the University of Bern, the Cochrane COVID‐19 Study Register, The Stephen B. Thacker CDC Library, and repositories of COVID‐19 publications through to 30 September 2020. We did not apply any language restrictions.
Selection criteria
We included studies of all designs, except for case‐control, that recruited participants of any age group suspected to have COVID‐19 and that reported estimates of test accuracy or provided data from which we could compute estimates.
Data collection and analysis
The review authors independently and in duplicate screened articles, extracted data and assessed risk of bias and applicability concerns using the QUADAS‐2 domain‐list. We presented the results of estimated sensitivity and specificity using paired forest plots, and we summarised pooled estimates in tables. We used a bivariate meta‐analysis model where appropriate. We presented the uncertainty of accuracy estimates using 95% confidence intervals (CIs).
Main results
We included 51 studies with 19,775 participants suspected of having COVID‐19, of whom 10,155 (51%) had a final diagnosis of COVID‐19. Forty‐seven studies evaluated one imaging modality each, and four studies evaluated two imaging modalities each. All studies used RT‐PCR as the reference standard for the diagnosis of COVID‐19, with 47 studies using only RT‐PCR and four studies using a combination of RT‐PCR and other criteria (such as clinical signs, imaging tests, positive contacts, and follow‐up phone calls) as the reference standard.
Studies were conducted in Europe (33), Asia (13), North America (3) and South America (2); including only adults (26), all ages (21), children only (1), adults over 70 years (1), and unclear (2); in inpatients (2), outpatients (32), and setting unclear (17).
Risk of bias was high or unclear in thirty‐two (63%) studies with respect to participant selection, 40 (78%) studies with respect to reference standard, 30 (59%) studies with respect to index test, and 24 (47%) studies with respect to participant flow.
For chest CT (41 studies, 16,133 participants, 8110 (50%) cases), the sensitivity ranged from 56.3% to 100%, and specificity ranged from 25.4% to 97.4%. The pooled sensitivity of chest CT was 87.9% (95% CI 84.6 to 90.6) and the pooled specificity was 80.0% (95% CI 74.9 to 84.3). There was no statistical evidence indicating that reference standard conduct and definition for index test positivity were sources of heterogeneity for CT studies.
Nine chest CT studies (2807 participants, 1139 (41%) cases) used the COVID‐19 Reporting and Data System (CO‐RADS) scoring system, which has five thresholds to define index test positivity. At a CO‐RADS threshold of 5 (7 studies), the sensitivity ranged from 41.5% to 77.9% and the pooled sensitivity was 67.0% (95% CI 56.4 to 76.2); the specificity ranged from 83.5% to 96.2%; and the pooled specificity was 91.3% (95% CI 87.6 to 94.0). At a CO‐RADS threshold of 4 (7 studies), the sensitivity ranged from 56.3% to 92.9% and the pooled sensitivity was 83.5% (95% CI 74.4 to 89.7); the specificity ranged from 77.2% to 90.4% and the pooled specificity was 83.6% (95% CI 80.5 to 86.4).
For chest X‐ray (9 studies, 3694 participants, 2111 (57%) cases) the sensitivity ranged from 51.9% to 94.4% and specificity ranged from 40.4% to 88.9%. The pooled sensitivity of chest X‐ray was 80.6% (95% CI 69.1 to 88.6) and the pooled specificity was 71.5% (95% CI 59.8 to 80.8).
For ultrasound of the lungs (5 studies, 446 participants, 211 (47%) cases) the sensitivity ranged from 68.2% to 96.8% and specificity ranged from 21.3% to 78.9%. The pooled sensitivity of ultrasound was 86.4% (95% CI 72.7 to 93.9) and the pooled specificity was 54.6% (95% CI 35.3 to 72.6).
Based on an indirect comparison using all included studies, chest CT had a higher specificity than ultrasound. For indirect comparisons of chest CT and chest X‐ray, or chest X‐ray and ultrasound, the data did not show differences in specificity or sensitivity.
Authors' conclusions
Our findings indicate that chest CT is sensitive and moderately specific for the diagnosis of COVID‐19. Chest X‐ray is moderately sensitive and moderately specific for the diagnosis of COVID‐19. Ultrasound is sensitive but not specific for the diagnosis of COVID‐19. Thus, chest CT and ultrasound may have more utility for excluding COVID‐19 than for differentiating SARS‐CoV‐2 infection from other causes of respiratory illness.
Future diagnostic accuracy studies should pre‐define positive imaging findings, include direct comparisons of the various modalities of interest in the same participant population, and implement improved reporting practices.
Different quantitative and qualitative indices calculated on oral panoramic radiographs have been proposed as useful tools to screen for reduced skeletal bone mineral density (BMD). Our aim was to ...systematically review the literature on linear and qualitative panoramic measures and to assess the accuracy of these indices by performing a meta-analysis of their sensitivity and specificity. The Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) statement was followed. Fifty studies were included in the qualitative appraisal and 19 were considered for meta-analysis. The methodological quality of the retrieved studies, assessed with the QUADAS-2 tool, was on average low. Three indices were reported by most of the studies: mandibular cortical width, panoramic mandibular index, and the Klemetti index. Mandibular cortical width presented with a better accuracy in excluding osteopenia/osteoporosis (specificity), since patients with a cortical width more than 4 mm had a normal BMD in 90% of the cases. Almost all studies used a cutoff of 0.3 for the panoramic mandibular index, resulting in an estimated sensitivity and specificity in detecting reduced BMD, respectively, of 0.723 (SE 0.160; 95% confidence interval CI, 0.352–0.926) and 0.733 (SE 0.066; 95% CI, 0.587–0.841). The presence of any kind of mandibular cortical erosion gave an estimated sensitivity and specificity in detecting reduced BMD, respectively, of 0.789 (SE 0.031; 95% CI, 0.721–0.843) and 0.562 (SE 0.047; 95% CI, 0.47–0.651) and a sensitivity and specificity in detecting osteoporosis, respectively, of 0.806 (SE 0.105; 95% CI, 0.528–0.9200) and 0.643 (SE 0.109; 95% CI, 0.417–0.820). The mandibular cortical width, panoramic mandibular index, and Klemetti index are overall useful tools that potentially could be used by dentists to screen for low BMD. Their limitations are mainly related to the experience/agreement between different operators and the different image quality and magnification of the panoramic radiographs.
Dual-energy CT enables the simultaneous acquisition of CT images at two different x-ray energy spectra. By acquiring high- and low-energy spectral data, dual-energy CT can provide unique qualitative ...and quantitative information about tissue composition, allowing differentiation of multiple materials including iodinated contrast agents. The two dual-energy CT postprocessing techniques that best exploit the advantages of dual-energy CT in children are the material-decomposition images (which include virtual nonenhanced, iodine, perfused lung blood volume, lung vessel, automated bone removal, and renal stone characterization images) and virtual monoenergetic images. Clinical applications include assessment of the arterial system, lung perfusion, neoplasm, bowel diseases, renal calculi, tumor response to treatment, and metal implants. Of importance, the radiation exposure level of dual-energy CT is equivalent to or less than that of conventional single-energy CT. In this review, the authors discuss the basic principles of the dual-energy CT technologies and postprocessing techniques and review current clinical applications in the pediatric chest and abdomen.
Chest radiography is an extremely powerful imaging modality, allowing for a detailed inspection of a patient's chest, but requires specialized training for proper interpretation. With the advent of ...high performance general purpose computer vision algorithms, the accurate automated analysis of chest radiographs is becoming increasingly of interest to researchers. Here we describe MIMIC-CXR, a large dataset of 227,835 imaging studies for 65,379 patients presenting to the Beth Israel Deaconess Medical Center Emergency Department between 2011-2016. Each imaging study can contain one or more images, usually a frontal view and a lateral view. A total of 377,110 images are available in the dataset. Studies are made available with a semi-structured free-text radiology report that describes the radiological findings of the images, written by a practicing radiologist contemporaneously during routine clinical care. All images and reports have been de-identified to protect patient privacy. The dataset is made freely available to facilitate and encourage a wide range of research in computer vision, natural language processing, and clinical data mining.
ObjectivesTo establish the level of observer variation for the current ATS/ERS/JRS/ALAT criteria for a diagnosis of usual interstitial pneumonia (UIP) on CT among a large group of thoracic ...radiologists of varying levels of experience.Materials and methods112 observers (96 of whom were thoracic radiologists) categorised CTs of 150 consecutive patients with fibrotic lung disease using the ATS/ERS/JRS/ALAT CT criteria for a UIP pattern (3 categories—UIP, possibly UIP and inconsistent with UIP). The presence of honeycombing, traction bronchiectasis and emphysema was also scored using a 3-point scale (definitely present, possibly present, absent). Observer agreement for the UIP categorisation and for the 3 CT patterns in the entire observer group and in subgroups stratified by observer experience, were evaluated.ResultsInterobserver agreement across the diagnosis category scores among the 112 observers was moderate, ranging from 0.48 (IQR 0.18) for general radiologists to 0.52 (IQR 0.20) for thoracic radiologists of 10–20 years’ experience. A binary score for UIP versus possible or inconsistent with UIP was examined. Observer agreement for this binary score was only moderate. No significant differences in agreement levels were identified when the CTs were stratified according to multidisciplinary team (MDT) diagnosis or patient age or when observers were categorised according to experience. Observer agreement for each of honeycombing, traction bronchiectasis and emphysema were 0.59±0.12, 0.42±0.15 and 0.43±0.18, respectively.ConclusionsInterobserver agreement for the current ATS/ERS/JRS/ALAT CT criteria for UIP is only moderate among thoracic radiologists, irrespective of their experience, and did not vary with patient age or the MDT diagnosis.
Nationwide surveys on radiation dose to the population from medical radiology are recommended in order to follow the trends in population exposure and ensure radiation protection.The last survey in ...Switzerland was conducted in 1998,and the annual effective dose from medical radiology was estimated to be 1 mSv y j(-1) per capita. The purpose of this work was to follow the trends in diagnostic radiology between 1998 and 2008 in Switzerland and determine the contribution of different modalities and types of examinations to the collective effective dose from medical x-rays. For this reason, an online database(www.raddose.ch) was developed. All healthcare providers who hold a license to run an x-ray unit in the country were invited to participate in the survey. More than 225 examinations, covering eight radiological modalities, were included in the survey. The average effective dose for each examination was reassessed. Data from about 3,500 users were collected (42% response rate). The survey showed that the annual effective dose was 1.2 mSv/capita in 2008. The most frequent examinations are conventional and dental radiographies (88%). The contribution of computed tomography was only 6% in terms of examination frequency but 68% in terms of effective dose. The comparison with other countries showed that the effective dose per capita in Switzerland was in the same range as in other countries with similar healthcare systems, although the annual number of examinations performed in Switzerland was higher.