Performance analysis of a high-efficiency multi-bed active magnetic regenerator deviceMasche, M. ...We present the performance of an active magnetic regenerator prototype with a multi-bed concept and parallel flow circuit. The prototype applies a two-pole permanent magnet (maximum magnetic flux ... density of 1.44 T) that rotates over 13 tapered regenerator beds mounted on a laminated iron yoke ring. Each bed is filled with about 262 g of spherical particles, distributed in layers of ten alloys of La(Fe,Mn,Si)13Hy (CALORIVAC HS) with different Curie temperatures. Other important features are the solenoid valves, the monitoring of the temperatures exiting each bed at the cold side, and a torque meter used to measure the magnetic power required to drive the cycle. The opening behavior of the solenoid valves (i.e., the blow fraction) could be adjusted to correct flow imbalances in each bed. The device provided a maximum cooling power of about 815 W at a cycle frequency of 1.2 Hz, a utilization of 0.36, and a hot reservoir temperature of 295 K while maintaining a 5.6 K-temperature span with a coefficient of performance of 6.0. In this case, the second-law efficiency was 11.6%. The maximum second-law efficiency of 20.5%, which represents one of the largest for a magnetocaloric device, was obtained at a cycle frequency of 0.5 Hz, a utilization of 0.34, and a hot reservoir temperature of 295 K at a temperature span of 10.3 K. Under these conditions, the device absorbed a cooling load of 288 W with a coefficient of performance of 5.7. It was also shown that an unbalanced flow due to different hydraulic resistance through the beds can cause cold side outlet temperature variations, which reduce the system performance, demonstrating the importance of a well-functioning, balanced flow system.Vir: Applied thermal engineering. - ISSN 1359-4311 (Vol. 199, Nov. 2021, str. 1-12)Vrsta gradiva - članek, sestavni delLeto - 2021Jezik - angleškiCOBISS.SI-ID - 94213635
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|---|
Masche, M. | |
Liang, Jierong | |
DallʹOlio, Stefano | 53663 |
Engelbrecht, Kurt | |
Bahl, Christian Robert Haffenden |
Vir: Osebne bibliografije
in: SICRIS
Izberite prevzemno mesto:
Prevzem gradiva po pošti
Naslov za dostavo:
Med podatki člana manjka naslov.
Storitev za pridobivanje naslova trenutno ni dostopna, prosimo, poskusite še enkrat.
S klikom na gumb "V redu" boste potrdili zgoraj izbrano prevzemno mesto in dokončali postopek rezervacije.
S klikom na gumb "V redu" boste potrdili zgoraj izbrano prevzemno mesto in naslov za dostavo ter dokončali postopek rezervacije.
S klikom na gumb "V redu" boste potrdili zgoraj izbrani naslov za dostavo in dokončali postopek rezervacije.
Obvestilo
Trenutno je storitev za avtomatsko prijavo in rezervacijo nedostopna. Gradivo lahko rezervirate sami na portalu Biblos ali ponovno poskusite tukaj kasneje.
Gesla v Splošnem geslovniku COBISS
Izbira mesta prevzema
Gradivo iz matične enote je brezplačno. Če je gradivo na mesto prevzema dostavljeno iz drugih enot, lahko knjižnica to storitev zaračuna.
Mesto prevzema | Status gradiva | Rezervacija |
---|
Rezervacija v teku
Prosimo, počakajte trenutek.
Rezervacija je uspela.
Rezervacija ni uspela.
Rezervacija...
Članska izkaznica:
Mesto prevzema: