DIKUL - logo
E-viri
Celotno besedilo
Recenzirano
  • User-Tailored Hand Gesture ...
    Meng, Long; Jiang, Xinyu; Liu, Xiangyu; Fan, Jiahao; Ren, Haoran; Guo, Yao; Diao, Haikang; Wang, Zihao; Chen, Chen; Dai, Chenyun; Chen, Wei

    IEEE transactions on instrumentation and measurement, 2022, Letnik: 71
    Journal Article

    Surface electromyogram (sEMG) based hand gesture recognition for prosthesis or armband is an important application of the human-machine interface. However, the measurement location of sensors greatly influences the hand gesture performance, especially with the inter-day or inter-subject validation protocols. Therefore, we acquired two-day hand gesture data of 41 subjects with a 256 (16×16) channel high-density sEMG electrode array. With the acquired data, we initially compared the support vector machine (SVM) and other four state-of-art classifiers under three validation protocols, i.e., intra-day, inter-day and inter-subject validation protocols. Then, we screened 14 feature optimization techniques, including 5 feature-projection methods and 9 feature-ranking approaches. To present the accuracy tendency with varying measure locations, we systematically explored the 10-hand gesture performance using data of 16 prosthesis measurement locations (PMLs) and 15 armband measurement locations (AMLs). As a result, the SVM classifier was suitable for the intra-day and inter-day validation protocols and the 2-dimensional convolutional neural network was selected for the inter-subject validation protocol. The mean accuracies of the hand gesture classification ranged from 95.68% to 99.12% (intra-day validation), from 68.41% to 88.02% (inter-day validation) and from 63.39% to 86.33% (inter-subject validation) for the prosthesis application. In addition, for the armband application, the mean accuracies ranged from 96.25% to 97.43% (intra-day validation), from 67.44% to 75.83% (inter-day validation) and from 65.53% to 75.40% (inter-subject validation). The accuracy is greatly correlated with the measurement location, which is highly associated with the neuromuscular structures of human bodies. In summary, our work can serve as a factor-screening tool for users customizing their systems according to their physical conditions and requirements.