    Aghris, S.; Ajermoun, N.; Loudiki, A.; Ettadili, F.E.; Laghrib, F.; Farahi, A.; Saqrane, S.; Bakasse, M.; Lahrich, S.; El Mhammedi, M.A.

    International journal of environmental analytical chemistry, 12/2023, Letnik: 103, Številka: 20
    Journal Article

    An analytical method for the determination of Flubendiamide (FBD) was investigated for the first time in this study using disposable pencil graphite electrodes (PGE). A detailed study of the electrochemical properties of FBD was carried out in phosphate buffer solution (PBS, pH 7.0). The results showed a well-defined reversible system result from the transformation of FBD to the corresponding hydroxyl-derivative. The results showed a linear range from 1 to 500 µM (R 2  = 0. 9952), as well as detection limit of 0.53 µM. The PGE sensor was successfully applied for the detection of FBD in wastewater and white rice.