E-viri
Recenzirano
-
Berkaev, D. E.; Shwartz, D. B.; Shatunov, P. Yu; Rogovskii, Yu. A.; Romanov, A. L.; Koop, I. A.; Shatunov, Yu. M.; Zemlyanskii, I. M.; Lysenko, A. P.; Perevedentsev, E. A.; Stankevich, A. S.; Senchenko, A. I.; Khazin, B. I.; Anisenkov, A. V.; Gayazov, S. E.; Kozyrev, A. N.; Ryzhenenkov, A. E.; Shemyakin, D. N.; Epshtein, L. B.; Serednyakov, S. I.; Astigeevich, P. M.; Kovrizhin, D. P.; Martin, K. A.; Obrazovskii, A. E.; Surin, I. K.; Kardapoltsev, L. V.; Belikov, O. V.; Gorchakov, K. M.; Kirpotin, A. N.; Skrinskii, A. N.
Journal of experimental and theoretical physics, 08/2011, Letnik: 113, Številka: 2Journal Article
In 2007, at the Institute of Nuclear Physics (Novosibirsk), the construction of the VEPP-2000 electron-positron collider was completed. The first electron beam was injected into the accelerator structure with turned-off solenoids of the final focus. This mode was used to tune all subsystems of the facility and to train the vacuum chamber using synchrotron radiation at electron currents of up to 150 mA. The VEPP-2000 structure with small beta functions and partially turned-on solenoids was used for the first testing of the “round beams” scheme at an energy of 508 MeV. Beam-beam effects were studied in strong-weak and strong-strong modes. Measurements of the beam sizes in both cases showed a dependence corresponding to model predictions for round colliding beams. Using a modernized SND (spherical neutral detector), the first energy calibration of the VEPP-2000 collider was performed by measuring the excitation curve of the phimeson resonance; the phi-meson mass is known with high accuracy from previous experiments at VEEP-2M. In October 2009, a KMD-3 (cryogenic magnetic detector) was installed at the VEPP-2000 facility, and the physics program with both the SND and LMD-3 particle detectors was started in the energy range of 1–1.9 GeV. This first experimental season was completed in summer 2010 with precision energy calibration by resonant depolarization.
Avtor
![loading ... loading ...](themes/default/img/ajax-loading.gif)
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|
Vir: Osebne bibliografije
in: SICRIS
To gradivo vam je dostopno v celotnem besedilu. Če kljub temu želite naročiti gradivo, kliknite gumb Nadaljuj.