DIKUL - logo
E-viri
Celotno besedilo
Recenzirano
  • Novel 1-L polyethylene glyc...
    Repici, Alessandro; Spada, Cristiano; Cannizzaro, Renato; Traina, Mario; Maselli, Roberta; Maiero, Stefania; Galtieri, Alessia; Guarnieri, Giovanni; Di Leo, Milena; Lorenzetti, Roberto; Capogreco, Antonio; Spadaccini, Marco; Antonelli, Giulio; Zullo, Angelo; Amata, Michele; Ferrara, Elisa; Correale, Loredana; Granata, Antonino; Cesaro, Paola; Radaelli, Franco; Minelli Grazioli, Leonardo; Anderloni, Andrea; Fugazza, Alessandro; Finati, Elena; Pellegatta, Gaia; Carrara, Silvia; Occhipinti, Pietro; Buda, Andrea; Fuccio, Lorenzo; Manno, Mauro; Hassan, Cesare

    Gastrointestinal endoscopy, October 2021, 2021-Oct, 2021-10-00, 20211001, Letnik: 94, Številka: 4
    Journal Article

    Adequate bowel cleansing is critical to ensure quality and safety of a colonoscopy. A novel 1-L polyethylene glycol plus ascorbate (1L-PEG+ASC) regimen was previously validated against low-volume regimens but was never compared with high-volume regimens. In a phase IV study, patients undergoing colonoscopy were randomized 1:1 to receive split-dose 1L PEG+ASC or a split-dose 4-L PEG-based regimen (4L-PEG) in 5 Italian centers. Preparation was assessed with the Boston Bowel Preparation Scale (BBPS) by local endoscopists and centralized reading, both blinded to the randomization arm. The primary endpoint was noninferiority of 1L-PEG+ASC in colon cleansing. Secondary endpoints were superiority of 1L-PEG+ASC, patient compliance, segmental colon cleansing, adenoma detection rate, tolerability, and safety. Three hundred eighty-eight patients (median age, 59.8 years) were randomized between January 2019 and October 2019: 195 to 1L-PEG+ASC and 193 to 4L-PEG. Noninferiority of 1L-PEG+ASC was demonstrated for cleansing in both the entire colon (BBPS ≥ 6: 97.9% vs 93%; relative risk RR, 1.03; 95% confidence interval CI, 1.001-1.04; P superiority = .027) and in the right-sided colon segment (98.4% vs 96.0%; RR, 1.02; 95% CI, .99-1.02; P noninferiority = .013). Compliance was higher with 1L-PEG+ASC than with 4L-PEG (178/192 92.7% vs 154/190 patients 81.1%; RR, 1.10; 95% CI, 1.05-1.12), whereas no difference was found regarding safety (moderate/severe side effects: 20.8% vs 25.8%; P = .253). No difference in adenoma detection rate (38.8% vs 43.0%) was found. One-liter PEG+ASC showed noninferiority compared with 4L-PEG in achieving adequate colon cleansing and provided a higher patient compliance. No differences in tolerability and safety were detected. (Clinical trial registration number: NCT03742232.)