E-viri
Recenzirano
-
Taneja, Sheeba; Mohan, Hosahalli K; Blake, Glen M; Livieratos, Lefteris; Clarke, Susan E.M
Nuclear medicine communications, 2008-April, Letnik: 29, Številka: 4Journal Article
AIMTo look at the combined impact of non-uniform attenuation correction (AC) and gated SPECT in the visual interpretation of myocardial SPECT imaging. This was compared to the individual benefit obtained by adding AC information and gated SPECT information to non-AC image information. MATERIALSWe retrospectively studied a group of 141 patients with a 22–26 month follow-up who underwent myocardial perfusion scintigraphy imaging. All the studies were corrected for attenuation with Gd line source transmission data and were ECG gated. In patients who had abnormal studies, follow-up coronary angiography information was also obtained in addition to medical follow-up information. METHODSTwo experienced nuclear medicine physicians interpreted the images independently and were blinded to the other personʼs report. Non-attenuation corrected data was first evaluated followed by attenuation corrected data and gated SPECT data. Four approaches to interpretation of images were undertaken(1) non-AC images only, (2) non-AC+AC images, (3) non-AC+gated images, and (4) non-AC+AC+gated images. Study results were divided into four categories based on how confident the observers were of the diagnosis(1) normal, (2) borderline normal, (3) borderline abnormal, and (4) abnormal. RESULTSWhen results for sensitivity and specificity using the four different interpretation techniques were compared there was a statistically significant improvement in the specificity compared to non-AC image (48%) with the addition of AC (77%) and gating (82%) information (P<0.001). The best improvement in the specificity was noted when both AC and gated information (91%) was used along with non-AC information. The normalcy rates almost doubled following the addition of AC and gated data. There was also a decrease in the number of borderline results, showing an improvement in the reporter confidence in interpreting myocardial SPECT studies. Sensitivity, however, did not show a significant change between the four different approaches to interpretation of the study. CONCLUSIONAttenuation correction and gating when combined have a synergistic impact upon improving the specificity of myocardial SPECT reporting when compared to the use of individual techniques alone to improve the specificity.
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|
Vir: Osebne bibliografije
in: SICRIS
To gradivo vam je dostopno v celotnem besedilu. Če kljub temu želite naročiti gradivo, kliknite gumb Nadaljuj.