E-viri
Recenzirano
Odprti dostop
-
Matsuda, Hiroshi; Murata, Miho; Mukai, Yohei; Sako, Kazuya; Ono, Hidetoshi; Toyama, Hiroshi; Inui, Yoshitaka; Taki, Yasuyuki; Shimomura, Hideo; Nagayama, Hiroshi; Tateno, Amane; Ono, Kenjiro; Murakami, Hidetomo; Kono, Atsushi; Hirano, Shigeki; Kuwabara, Satoshi; Maikusa, Norihide; Ogawa, Masayo; Imabayashi, Etsuko; Sato, Noriko; Takano, Harumasa; Hatazawa, Jun; Takahashi, Ryosuke
European journal of nuclear medicine and molecular imaging, 07/2018, Letnik: 45, Številka: 8Journal Article
Purpose The aim of this multicenter trial was to generate a 123 IFP-CIT SPECT database of healthy controls from the common SPECT systems available in Japan. Methods This study included 510 sets of SPECT data from 256 healthy controls (116 men and 140 women; age range, 30–83 years) acquired from eight different centers. Images were reconstructed without attenuation or scatter correction (NOACNOSC), with only attenuation correction using the Chang method (ChangACNOSC) or X-ray CT (CTACNOSC), and with both scatter and attenuation correction using the Chang method (ChangACSC) or X-ray CT (CTACSC). These SPECT images were analyzed using the Southampton method. The outcome measure was the specific binding ratio (SBR) in the striatum. These striatal SBRs were calibrated from prior experiments using a striatal phantom. Results The original SBRs gradually decreased in the order of ChangACSC, CTACSC, ChangACNOSC, CTACNOSC, and NOACNOSC. The SBRs for NOACNOSC were 46% lower than those for ChangACSC. In contrast, the calibrated SBRs were almost equal under no scatter correction (NOSC) conditions. A significant effect of age was found, with an SBR decline rate of 6.3% per decade. In the 30–39 age group, SBRs were 12.2% higher in women than in men, but this increase declined with age and was absent in the 70–79 age group. Conclusions This study provided a large-scale quantitative database of 123 IFP-CIT SPECT scans from different scanners in healthy controls across a wide age range and with balanced sex representation. The phantom calibration effectively harmonizes SPECT data from different SPECT systems under NOSC conditions. The data collected in this study may serve as a reference database.
Avtor
![loading ... loading ...](themes/default/img/ajax-loading.gif)
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|
Vir: Osebne bibliografije
in: SICRIS
To gradivo vam je dostopno v celotnem besedilu. Če kljub temu želite naročiti gradivo, kliknite gumb Nadaljuj.