UNI-MB - logo
UMNIK - logo
 

Search results

Basic search    Expert search   

Currently you are NOT authorised to access e-resources UM. For full access, REGISTER.

1
hits: 9
1.
  • Performances of the CsI(Tl)... Performances of the CsI(Tl) detector element of the GLAST calorimeter
    Bédérède, D.; Bougamont, E.; Bourgeois, Ph ... Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 02/2004, Volume: 518, Issue: 1
    Journal Article
    Peer reviewed

    The CsI(Tl) Detector Element (CDE) is the unit of detection of the calorimeter subsystem of the Large Area Telescope (LAT) of the GLAST satellite (IEEE Nuclear Science Symposium, 2002), which will be ...
Full text
2.
  • Environmental tests of the ... Environmental tests of the GLAST validation module calorimeter
    Ferreira, O.; Bogaert, G.; Bonnemaison, A. ... Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 09/2004, Volume: 530, Issue: 3
    Journal Article
    Peer reviewed

    This paper describes the results of vibration tests using the Validation Module of the GLAST Gamma Large Area Telescope calorimeter structure. The composite structure has been tested with different ...
Full text
3.
  • High resolution drift chamb... High resolution drift chambers for the NA48 experiment at CERN
    Béderède, D; Chèze, J.B; De Beer, M ... Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 12/1995, Volume: 367, Issue: 1
    Journal Article
    Peer reviewed

    We discuss construction details of large drift chambers for the NA48 experiment at CERN. Preliminary measurements on their performance are also presented.
Full text
4.
  • SICAL — a high precision si... SICAL — a high precision silicon-tungsten luminosity calorimeter for ALEPH
    Bédérède, D.; Beuville, E.; Bloch-Devaux, B. ... Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 11/1995, Volume: 365, Issue: 1
    Journal Article
    Peer reviewed
    Open access

    The design, construction and performance of a silicon-tungsten electromagnetic calorimeter built to achieve an experimental luminosity measurement precision at LEP≤0.1% is described. The detector ...
Full text

PDF
5.
  • The beam and detector for t... The beam and detector for the NA48 neutral kaon CP violation experiment at CERN
    Fanti, V.; Lai, A.; Nappi, A. ... Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 05/2007, Volume: 574, Issue: 3
    Journal Article
    Peer reviewed
    Open access

    The beam and detector, used for the NA48 experiment, devoted to the measurement of Re ( ε ′ / ε ) , and for the NA48/1 experiment on rare K S and neutral hyperon decays, are described.
Full text

PDF
6.
  • The On-orbit Calibrations f... The On-orbit Calibrations for the Fermi Large Area Telescope
    A. Abdo, A.; Ackermann, Markus; Ajello, Marco ... Astroparticle physics, 10/2009, Volume: 32
    Journal Article
    Peer reviewed

    The Large Area Telescope (LAT) on--board the Fermi Gamma ray Space Telescope began its on--orbit operations on June 23, 2008. Calibrations, defined in a generic sense, correspond to synchronization ...
Full text

PDF
7.
Full text
8.
  • Performance of an electroma... Performance of an electromagnetic liquid krypton calorimeter based on a ribbon electrode tower structure
    Barr, G.D.; Bruschini, C.; Bocquet, C. ... Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 02/1996, Volume: 370, Issue: 2
    Journal Article
    Peer reviewed
    Open access

    The NA48 collaboration is preparing a new experiment at CERN aiming to study CP violation in the K 0- K 0 system with an accuracy of 2 × 10 −4 in the parameter R e(ϵ′/ϵ). Decays in two π 0's will be ...
Full text

PDF
9.
  • A purity monitoring system ... A purity monitoring system for the H1 liquid argon calorimeter
    Barrelet, E.; Andrieu, B.; Babaev, A. ... Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 09/2002, Volume: 490, Issue: 1
    Journal Article
    Peer reviewed
    Open access

    The ionization probes used for monitoring the liquid argon purity in the H1 calorimeter are described and results of their operation in tests at CERN and during the period 1992 to the end of 1998 at ...
Full text

PDF
1
hits: 9

Load filters