We report on a search for particle dark matter with the XENON100 experiment, operated at the Laboratori Nazionali del Gran Sasso for 13 months during 2011 and 2012. XENON100 features an ultralow ...electromagnetic background of (5.3 ± 0.6) × 10(-3) events/(keV(ee) × kg × day) in the energy region of interest. A blind analysis of 224.6 live days × 34 kg exposure has yielded no evidence for dark matter interactions. The two candidate events observed in the predefined nuclear recoil energy range of 6.6-30.5 keV(nr) are consistent with the background expectation of (1.0 ± 0.2) events. A profile likelihood analysis using a 6.6-43.3 keV(nr) energy range sets the most stringent limit on the spin-independent elastic weakly interacting massive particle-nucleon scattering cross section for weakly interacting massive particle masses above 8 GeV/c(2), with a minimum of 2 × 10(-45) cm(2) at 55 GeV/c(2) and 90% confidence level.
To improve the efficiency of a diesel internal combustion engine (ICE), the waste heat carried out by the combustion gases can be recovered with an organic Rankine cycle (ORC) that further drives a ...vapor compression refrigeration cycle (VCRC). This work offers an exergoeconomic optimization methodology of the VCRC-ORC group. The exergetic analysis highlights the changes that can be made to the system structure to reduce the exergy destruction associated with internal irreversibilities. Thus, the preheating of the ORC fluid with the help of an internal heat exchanger leads to a decrease in the share of exergy destruction in the ORC boiler by 4.19% and, finally, to an increase in the global exergetic yield by 2.03% and, implicitly, in the COP of the ORC-VCRC installation. Exergoeconomic correlations are built for each individual piece of equipment. The mathematical model for calculating the monetary costs for each flow of substance and energy in the system is presented. Following the evolution of the exergoeconomic performance parameters, the optimization strategy is developed to reduce the exergy consumption in the system by choosing larger or higher-performance equipment. When reducing the temperature differences in the system heat exchangers (ORC boiler, condenser, and VCRC evaporator), the unitary cost of the refrigeration drops by 44%. The increase in the isentropic efficiency of the ORC expander and VCRC compressor further reduces the unitary cost of refrigeration by another 15%. Following the optimization procedure, the cost of the cooling unit drops by half. The cost of diesel fuel has a major influence on the unit cost of cooling. A doubling of the cost of diesel fuel leads to an 80% increase in the cost of the cold unit. The original merit of the work is to present a detailed and comprehensive model of optimization based on exergoeconomic principles that can serve as an example for any thermal system optimization.
We present new experimental constraints on the elastic, spin-dependent WIMP-nucleon cross section using recent data from the XENON100 experiment, operated in the Laboratori Nazionali del Gran Sasso ...in Italy. An analysis of 224.6 live days×34 kg of exposure acquired during 2011 and 2012 revealed no excess signal due to axial-vector WIMP interactions with 129Xe and 131Xe nuclei. This leads to the most stringent upper limits on WIMP-neutron cross sections for WIMP masses above 6 GeV/c², with a minimum cross section of 3.5×10(-40) cm² at a WIMP mass of 45 GeV/c², at 90% confidence level.
The objective of this study was to explore the acceptability of rapid HIV self-testing (RHST) among men who have sex with men (MSM).
During 2006-2009, a sample of 500 MSM was recruited through ...Respondent Driven Sampling for an HIV prevalence/incidence study. Attitude toward RHST was explored among HIV negative MSM. Data were weighted prior to analyses.
Participants reported they were likely to buy RHST (74%), test themselves more frequently than they currently do (77%), and that the procedure would simplify testing (70%). Furthermore, 71% reported they would probably use it alone, 66% would use it with a steady partner, and 56% with a friend/partner. While a majority acknowledged that RHST use would deprive them of receiving counseling (61%), 74% declared they would go for help if they tested positive; 57% would use an RHST in order to avoid condoms. Probability of use surpassed 70% among gay and non-gay identified MSM as well as those with and without a previous HIV test. Those likely to buy RHST were older (p = 0.025) and more likely to identify as gay (p = 0.036). A total of 17% said they would think about killing themselves and 9% would attempt suicide if they tested positive. These MSM were more likely to be younger (p<0.001), with lower mood level (p<0.001) and greater feelings of loneliness (p = 0.026).
The high acceptability of RHST found among MSM should encourage the authorities to consider the possibility of offering it for self-testing, as it can improve early diagnosis and prevention of future transmissions. However, further research is needed to understand how to best disseminate RHST among MSM who wish to use it and to offer support and linkage to care for those who test HIV-positive.
Gay, bisexual, and other men who have sex with men (MSM) experience alarming HIV disparities alongside sub-optimal engagement in HIV interventions. Among MSM, stigma toward anal sexuality could ...interfere with engagement in HIV prevention, yet few studies have examined MSM perspectives on anal sex stigma or its health-related sequelae. Guided by theory, we aimed to characterize anal sex stigma, related sexual concerns, and barriers to health seeking, like concealment. We elicited community input by purposively interviewing 10 experts in MSM health and then 25 racially, ethnically, and geographically diverse cisgender MSM. Participants reported experienced, internalized, and anticipated forms of anal sex stigma that inhibited health seeking. Experienced stigma, including direct and observed experiences as well as the absence of sex education and information, contributed to internalized stigma and anticipation of future devaluation. This process produced psychological discomfort and concealment of health-related aspects of anal sexuality, even from potentially supportive sexual partners, social contacts, and health workers. Participants characterized stigma and discomfort with disclosure as normative, pervasive, and detrimental influences on health-seeking behavior both during sex and within healthcare interactions. Omission of information appears to be a particularly salient determinant of sexual behavior, inhibiting prevention of harm, like pain, and leading to adverse health outcomes. The development of measures of anal sex stigma and related sexual concerns, and testing their impact on comfort with disclosure, sexual practices, and engagement in health services could identify modifiable social pathways that contribute to health disparities among MSM, like those seen in the HIV epidemic.
This case study analyzes a cryogenic air separation unit (ASU) with a production of V˙O2=58,300 m3Nh of gaseous oxygen with a concentration greater than 98.5%, operating in Romania on a steel plant ...platform. The goal of the paper is to provide an extensive model of exergetic analysis that could be used in an optimization procedure when decisional parameters are changed or structural design modifications are implemented. For each key part of the Air Separation Unit, an exergetic product and fuel were defined and, based on their definition, the coefficient of performance of each functional zone was calculated. The information about the magnitude of the exergetic losses offers solutions for their future recovery. The analysis of the exergy destructions suggests when it is worth making a larger investment. The exergetic analysis of the compression area of the ASU points out an exergy destruction and loss of 37% from the total plant's electrical energy input. The exergy loss with the heat transferred to the cooling system of compressors can be recovered; for the exergy destruction portion, the challenge between investment and operating costs should be considered. The exergy destruction of the air separation columns found the High Pressure Column (HPC) to be more destructive than the Low Pressure Column. The share of the exergy destruction in the total plant's electrical energy input is 8.3% for the HPC. The local COP of the HPC, calculated depending on the total exergy of the local product and fuel, is 62.66%. The calculus of the air separation column is performed with the ChemSep simulator.
The study proposes a method for preliminary and estimative sizing of the main components of solar district heating systems, with seasonal thermal storage. The main parameters determined by this ...method, are the aperture area of the solar thermal collectors and the volume of the seasonal thermal storage. The proposed method is only estimative, but it provides the necessary input data for the investigation ofthe dynamic thermal behavior of such systems. The main advantage of the method is that it requires only very few and accessible input data. Two situations are considered: the first in which available climatic data such as annual global solar radiation on horizontal plane and annual average temperature can be used in calculations, and the second in which such data is not available and should be determined through interpolation. With the proposed interpolation functions the annual global solar radiation on horizontal plane, the annual average temperature and the annual global efficiency of the solar thermal collectors were determined. The errors of the estimations are ranging within the intervals of (−15.6 … +25.8) % for annual global solar radiation on horizontal plane and (−10.8 … 19.1) % for annual global efficiency of the solar thermal collectors. The maximum deviations for the annual average temperature estimations were (−4.23 … +5.37) °C. With this limited accuracy, the proposed interpolation functions can be used for latitudes between (0–70) °, annual global solar radiation on horizontal plane between (704–2337) kWh/m2/year and annual average temperatures ranging within the interval of (2–30) °C.
Solar district heating, Seasonal thermal storage, Preliminary sizing, Web based application, Aperture area, Storage system volume.
With the escalating frequency of cybersecurity threats in public cloud computing environments, there is a pressing need for robust security measures to safeguard sensitive data and applications. This ...research addresses growing security concerns in the cloud by proposing an innovative security information and event management system (SIEM) that offers automated visibility of cloud resources. Our implementation includes a virtual network comprising virtual machines, load balancers, Microsoft Defender for Cloud, and an application gateway that functions as a web application firewall (WAF). This WAF scans incoming Internet traffic and provides centralized protection against common exploits and vulnerabilities, securing web applications within the cloud environment. We deployed the SIEM system to automate visibility and incident response for cloud resources. By harnessing the power of this employed SIEM, the developed system can continuously monitor, detect security incidents, and proactively mitigate potential security threats. Microsoft Defender for Cloud consistently assesses the configuration of cloud resources against industry standards, regulations, and benchmarks to ensure compliance requirements are met. Our findings highlight the practicality and effectiveness of deploying such solutions to safeguard cloud resources, offering valuable insights to organizations and security professionals seeking sustainable and resilient security measures in the cloud computing environment.
The study carried out by simulation, concerns the thermal behavior of an office building’s solar fresh air cooling system, based on a LiBr-H2O absorption chiller in different climatic conditions. The ...coefficient of performance (COP) and the solar fraction were considered performance parameters and were analyzed with respect to the operating limits—the risk of crystallization and maintaining at least a minimum degassing zone. A new correlation between the required solar hot temperature and the cooling water temperature was established and then embedded in another new correlation between the COP and the cooling water temperature that was used in simulations during the whole cooling season corresponding to each location. It was found that—the solar hot water should be maintained in the range of (80–100) °C depending on the cooling water temperature, the COP of the solar LiBr-H2O absorption chiller with or without cold storage tank could reach (76.5–82.4)% depending on the location, and the solar fraction could reach (29.5–62.0)% without cold storage tank and could exceed 100% with cold storage tank, and the excess cooling power being available to cover other types of cooling loads—through the building envelope, from lighting, and from occupants, etc.