Secondary discharge studies in single- and multi-GEM structures Deisting, A.; Garabatos, C.; Gasik, P. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
09/2019, Volume:
937
Journal Article
Peer reviewed
Open access
Secondary discharges, which consist of the breakdown of a gap near a GEM foil upon a primary discharge across that GEM, are studied in this work.
Their main characteristics are the occurrence a few ...10μs after the primary, the relatively sharp onset at moderate electric fields across the gap, the absence of increased fields in the system, and their occurrence under both field directions.
They can be mitigated using series resistors in the high-voltage connection to the GEM electrode facing towards an anode. The electric field at which the onset of secondary discharges occurs indeed increases with increasing resistance. Discharge propagation from GEM to GEM in a multi-GEM system affects the occurrence probability of secondary discharges in the gaps between neighbouring GEMs.
Furthermore, evidence of charges flowing through the gap after the primary discharge are reported. Such currents may or may not lead to a secondary discharge. A characteristic charge, of the order of 1010 electrons, has been measured as the threshold for a primary discharge to be followed by a secondary discharge, and this number slightly depends on the gas composition. A mechanism involving the heating of the cathode surface as trigger for secondary discharges is proposed.
Computer simulations of cylindrical Compton Ar-Xe gamma camera are described in the current report. Detection efficiency of cylindrical Ar-Xe Compton camera with internal diameter of 40 cm is ...estimated as1-3%that is 10-100 times higher than collimated Anger's camera. It is shown that cylindrical Compton camera can image Tc-99m radiotracer distribution with uniform spatial resolution of 20 mm through the whole field of view.
To determine the depth of the area of radiopharmaceutical accumulation a method of simultaneous recording of two lines of gamma rays of different energies and quantitative comparison of the intensity ...of these lines on the surface of the patient's body is provided. Since the coefficient of linear absorption of gamma radiation in the medium depends not only on the characteristics of the medium, but also on the gamma radiation energy, the intensity of gammas of different energies is attenuated differently after passing through the same absorber layer (soft tissues). Thus, the quantitative comparison of the relative intensities of gamma lines on the surface of the patient's body allows to determine the depth of area of the accumulation of the radiopharmaceutical. The result is achieved by analyzing the energy spectrum of the source, obtained with a semiconductor spectrometer, by measuring the ratio of areas of the absorption peaks of the radioisotope and defining the depth of gamma source using the calibration dependence between the areas ratio and the medium layer thickness. The most widely used medical radioisotope technetium-99m has two gamma-lines - 140 keV and 18.5keV, which allows one to apply the proposed method to search for the sentinel lymph nodes and non-palpable malignant tumors in the soft tissues.
The RED-100 (Russian Emission Detector) is being constructed for the experiment to search for elastic coherent neutrino scattering off atomic nuclei. This fundamental process was predicted several ...decades ago by the Standard Model of electroweak interactions but has not been discovered yet. The RED-100 is a two-phase emission xenon detector containing ∼200 kg of the liquid Xe (∼ 100 kg of that is in a fiducial volume). One of the possible sites to carry out the experiment is the SNS (Spallation Neutron Source) facility at Oak Ridge National Laboratory, USA. SNS is the world's most intense pulsed source of neutrinos and unique place to study neutrino properties. The energy spectrum of neutrinos produced at the SNS extends up to ∼ 50 MeV and satisfies coherence condition. These neutrinos give kinetic energies of Xe recoils up to a few tens of keV where the response of nuclear recoils is well-known from neutron calibrations of dark matter detectors. The detector will be deployed in the basement under the experimental hall at a distance of ∼30 meters from the SNS target. The expected signal and background (neutron and gamma) are estimated for this specific location. The detector details, current status and future plans are provided.