The status of vasa vasorum, which can be imaged using ultrasound contrast agents, is an indication for the progression of atherosclerosis. The preferred ultrasound frequency for this purpose is ...between 5 and 15 MHz. Therefore, it is essential to have knowledge about the acoustic properties of microbubbles such as elasticity and viscosity to be able to implement the current models for lipid encapsulated microbubbles developed for frequencies used in precordial imaging. In this study, the shell parameters, stiffness S(p) and friction S(f), of Definity™ microbubbles have been calculated at frequency range of 5-15 MHz by comparing the theoretical modeling of acoustic bubble response and experimental measurements. Derived parameters are in good agreement with previous estimations on SonoVue™ and Sonazoid™ contrast agent. However, the value of S(f) is higher than previously estimated for Definity™ between 12-28 MHz.
Software is as integral as a research paper, monograph, or dataset in terms of facilitating the full understanding and dissemination of research. This article provides broadly applicable guidance on ...software citation for the communities and institutions publishing academic journals and conference proceedings. We expect those communities and institutions to produce versions of this document with software examples and citation styles that are appropriate for their intended audience. This article (and those community-specific versions) are aimed at authors citing software, including software developed by the authors or by others. We also include brief instructions on how software can be made citable, directing readers to more comprehensive guidance published elsewhere. The guidance presented in this article helps to support proper attribution and credit, reproducibility, collaboration and reuse, and encourages building on the work of others to further research.
A comparison between phospholipid-coated microbubbles with and without liposomes attached to the microbubble surface was performed using the ultra-high-speed imaging camera (Brandaris 128). We ...investigated 73 liposome-loaded microbubbles (loaded microbubbles) and 41 microbubbles without liposome loading (unloaded microbubbles) with a diameter ranging from 3-10 μm at frequencies ranging from 0.6-3.8 MHz and acoustic pressures ranging from 5-100 kPa. The experimental data showed nearly the same shell elasticity for the loaded and unloaded bubbles, but the shell viscosity was higher for loaded bubbles compared with unloaded bubbles. For loaded bubbles, a higher pressure threshold for the bubble vibrations was noticed. In addition, an "expansion-only" behavior was observed for up to 69% of the investigated loaded bubbles, which mostly occurred at low acoustic pressures (≤30 kPa). Finally, fluorescence imaging showed heterogeneity of liposome distributions of the loaded bubbles.
We investigated the spontaneous capillarity-driven filling of nanofluidic channels with a thickness of 6 and 16 nm using mixtures of ethanol and water of variable composition. To improve the ...visibility of the fluid, we embedded metal mirrors into the top and bottom walls of the channels that act as a Fabry–Pérot interferometer. The motion of propagating liquid–air menisci was monitored for various concentrations in transmission with an optical microscope. In spite of the visible effects of surface roughness and different affinity of water and ethanol to the channel walls, the dynamics followed the classical
t
1/2
—dependence according to Lucas and Washburn. While the prefactor of this algebraic relation falls short of the expectations based on bulk properties by 10–30%, the relative variation between mixtures of different composition follows the expectations based on the bulk surface tension and viscosity, implying that—despite the small width of the channels and the large surface-to-volume ratio—specific adsorption or chemical selectivity effects are not relevant. We briefly discuss the impact of surface roughness on our experimental results.
The Brandaris 128 ultra-high-speed imaging facility has been updated over the last 10 years through modifications made to the camera's hardware and software. At its introduction the camera was able ...to record 6 sequences of 128 images (500 × 292 pixels) at a maximum frame rate of 25 Mfps. The segmented mode of the camera was revised to allow for subdivision of the 128 image sensors into arbitrary segments (1-128) with an inter-segment time of 17 μs. Furthermore, a region of interest can be selected to increase the number of recordings within a single run of the camera from 6 up to 125. By extending the imaging system with a laser-induced fluorescence setup, time-resolved ultra-high-speed fluorescence imaging of microscopic objects has been enabled. Minor updates to the system are also reported here.