The electronics system of the TOTEM T1 telescope Minutoli, S.; Bozzo, M.; Ferro, F. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
08/2013, Volume:
718
Journal Article
Peer reviewed
The T1 detector of the TOTEM experiment is devoted to the measurement of the inelastic rate of proton–proton interactions at the LHC. It is made of Cathode Strip Chambers. The complete electronic ...chains of front-end, readout and trigger are presented here. The electronics system has been developed keeping into account the hostile environment from the point of view of both radiation and magnetic field. Dedicated VLSI circuits have been extensively used in order to optimize space and power consumption.
Abstract
Objective
Develop and evaluate an interactive information visualization embedded within the electronic health record (EHR) by following human-centered design (HCD) processes and leveraging ...modern health information exchange standards.
Materials and Methods
We applied an HCD process to develop a Fast Healthcare Interoperability Resources (FHIR) application that displays a patient’s asthma history to clinicians in a pediatric emergency department. We performed a preimplementation comparative system evaluation to measure time on task, number of screens, information retrieval accuracy, cognitive load, user satisfaction, and perceived utility and usefulness. Application usage and system functionality were assessed using application logs and a postimplementation survey of end users.
Results
Usability testing of the Asthma Timeline Application demonstrated a statistically significant reduction in time on task (P < .001), number of screens (P < .001), and cognitive load (P < .001) for clinicians when compared to base EHR functionality. Postimplementation evaluation demonstrated reliable functionality and high user satisfaction.
Discussion
Following HCD processes to develop an application in the context of clinical operations/quality improvement is feasible. Our work also highlights the potential benefits and challenges associated with using internationally recognized data exchange standards as currently implemented.
Conclusion
Compared to standard EHR functionality, our visualization increased clinician efficiency when reviewing the charts of pediatric asthma patients. Application development efforts in an operational context should leverage existing health information exchange standards, such as FHIR, and evidence-based mixed methods approaches.
Introduction
Pulse oximetry monitoring is prescribed to children receiving home oxygen for chronic medical conditions associated with hypoxemia. Although home pediatric pulse oximetry is supported by ...national organizations, there is a lack of guidelines outlining indications and prescribing parameters.
Methods
A mixed‐methods analysis of pediatric home pulse oximetry orders prescribed through the institutional home healthcare provider at a large US children's hospital 6/2018–7/2019 was retrospectively reviewed to determine prescribed alarm parameter limits and recommended interventions. Semi‐structured qualitative interviews with pediatric providers managing patients receiving home oxygen and pulse oximetry were conducted to identify opportunities to improve home pulse oximetry prescribing practices. Interviews were analyzed using a modified content analysis approach to identify recurring themes.
Results
A total of 368 children received home pulse oximetry orders. Orders were most frequently prescribed on noncardiac medical floors (32%). Attending physicians were the most frequent ordering providers (52%). Frequency of use was prescribed in 96% of orders, however, just 70% were provided with specific instructions for interventions when alarms occurred. Provider role and clinical setting were significantly associated with the presence of a care plan. Provider interviews identified opportunities for improvement with the device, management of alarm parameter limits, and access to home monitor data.
Discussion
This study demonstrated significant variability in home pulse oximetry prescribing practices. Provider interviews highlighted the importance of the provider–patient relationship and areas for improvement. There is an opportunity to create standardized guidelines that optimize the use of home monitoring devices for patients, families, and pulmonary providers.
Continuous physiologic monitoring commonly is used in pediatric medical-surgical (med-surg) units and is associated with high alarm burden for clinicians. Characteristics of pediatric patients ...generating high rates of alarms on med-surg units are not known.
To describe the demographic and clinical characteristics of pediatric med-surg patients associated with high rates of clinical alarms.
We conducted a cross-sectional, single-site, retrospective study using existing clinical and alarm data from a children's hospital. Continuously monitored patients from med-surg units who had available alarm data were included. Negative binomial regression models were used to test the association between patient characteristics and the rate of clinical alarms per continuously monitored hour.
Our final sample consisted of 1,569 patients with a total of 38,501 continuously monitored hours generating 265,432 clinical alarms. Peripheral oxygen saturation (SpO
) low alarms accounted for 57.5% of alarms. Patients with medical complexity averaged 11% fewer alarms per hour than those without medical complexity (
< 0.01). Patients older than 5 years had up to 30% fewer alarms per hour than those who were younger than 5 years (
< 0.01). Patients using supplemental oxygen averaged 39% more alarms per hour compared with patients who had no supplemental oxygen use (
< 0.01). Patients at high risk for deterioration averaged 19% more alarms per hour than patients who were not high risk (
= 0.01).
SpO
alarms were the most common type of alarm in this study. The results highlight patient populations in pediatric medical-surgical units that may be high yield for interventions to reduce alarms. Most physiologic monitor alarms in pediatric medical-surgical (med-surg) units are not informative and likely could be safely eliminated to reduce noise and alarm fatigue.
However, identifying and sustaining successful alarm-reduction strategies is a challenge. Research shows that 25% of patients in pediatric med-surg units produce almost three-quarters of all alarms.
These patients are a potential high-yield target for alarm-reduction strategies; however, we are not aware of studies describing characteristics of pediatric patients generating high rates of alarms. The patient populations seen on pediatric med-surg units are diverse. Children of all ages are cared for on these units, with diagnoses ranging from acute respiratory infections, to management of chronic conditions, and to psychiatric conditions. Not all patients on pediatric med-surg units have physiologic parameters continuously monitored,
but among those who do, understanding patient characteristics associated with high rates of alarms may help clinicians, healthcare technology management (HTM) professionals, and others working on alarm management strategies to develop targeted interventions. We conducted an exploratory retrospective study to describe patient characteristics associated with high rates of alarms in pediatric med-surg units.
Escherichia coli and Staphylococcus aureus are important agents of urinary tract infections that can often evolve to severe infections. The rise of antibiotic-resistant strains has driven the search ...for novel therapies to replace the use or act as adjuvants of antibiotics. In this context, plant-derived compounds have been widely investigated. Cuminaldehyde is suggested as the major antimicrobial compound of the cumin seed essential oil. However, this effect is not fully understood. Herein, we investigated the in silico and in vitro activities of cuminaldehyde, as well as its ability to potentiate ciprofloxacin effects against S. aureus and E. coli. In silico analyses were performed by using different computational tools. The PASS online and SwissADME programmes were used for the prediction of biological activities and oral bioavailability of cuminaldehyde. For analysis of the possible toxic effects and the theoretical pharmacokinetic parameters of the compound, the Osiris, SwissADME and PROTOX programmes were used. Estimations of cuminaldehyde gastrointestinal absorption, blood brain barrier permeability and skin permeation by using SwissADME; and drug likeness and score by using Osiris, were also evaluated The in vitro antimicrobial effects of cuminaldehyde were determined by using microdilution, biofilm formation and time-kill assays. In silico analysis indicated that cuminaldehyde may act as an antimicrobial and as a membrane permeability enhancer. It was suggested to be highly absorbable by the gastrointestinal tract and likely to cross the blood brain barrier. Also, irritative and harmful effects were predicted for cuminaldehyde if swallowed at its LD50. Good oral bioavailability and drug score were also found for this compound. Cuminaldehyde presented antimicrobial and anti-biofilm effects against S. aureus and E. coli.. When co-incubated with ciprofloxacin, it enhanced the antibiotic antimicrobial and anti-biofilm actions. We suggest that cuminaldehyde may be useful as an adjuvant therapy to ciprofloxacin in S. aureus and E. coli-induced infections.